safety light curtain type 4 - XUSLP - height 400 mm - 3 beams

Show more characteristics >
Add to My Products Remove from My Products

XUSLPZ3A0400M is replaced by:
Product
Qty
XUSL4E3BB081N
Qty
1
Add to My Products Remove from My Products
  • Reason for Substitution: End of life
  • Substitution date: 12 June 2014
  • -
1
  • Main
    range of product
    Preventa Safety detection
    product or component type
    Safety light curtain type 4
    device short name
    XUSLP
    design
    Compact
    detection system
    Transmitter-receiver system
    product specific application
    For body protection
    height protected
    800 mm
    minimum object diameter for detection
    400 mm
    [Sn] nominal sensing distance
    0.8...20 m depending on configuration
    0.8...70 m depending on configuration
    response time
    < 16 ms depending on light beam coding C
    < 20 ms depending on light beam coding B
    < 24 ms depending on light beam coding A
    number of beams
    3
    type of receiver
    Active
    Complementary
    kit composition
    1 receiver(s)
    1 transmitter(s)
    1 user guide with certificate of conformity
    2 sets of 2 brackets with fixings
    [EAA] effective aperture angle
    2.5 ° at 3 m
    light source
    GaAIAs LED, 850 nm
    [Us] rated supply voltage
    24 V DC (+/- 20 %)
    [Ie] rated operational current
    2 A
    current consumption
    100 mA (transmitter)
    300 mA no-load (receiver)
    1.6 A with maximum load (receiver)
    output type
    1 auxiliary output solid-state PNP
    2 safety outputs OSSD solid-state PNP (NO) (short-circuit protection)
    output current limits
    <= 100 mA for auxiliary output
    <= 650 mA for safety outputs OSSD
    output voltage
    24 V
    output circuit type
    DC
    switching capacity in mA
    650 mA
    monitoring act of of relay MPCE/EDM
    50 mA
    local signalling
    1 LED (transmitter), function: power supply
    3 LEDs (receiver), function: stop, run, interlock + 2 digit display
    electrical connection
    1 male connector M12 5 pins (transmitter)
    1 male connector M12 8 pins (receiver)
    function available
    Alignment aid by display of each light beam broken
    Auto, manual, manual 1st cycle
    Display of operating modes and alarm by LEDs and 2-digit display
    Monitoring of external switching devices
    Test
    marking
    CE
    material
    Casing : aluminium
    End caps : 20 % fibre glass impregnated nylon
    Front face : acrylic
    fixing mode
    End brackets
    product weight
    7.2 kg
    Environment
    standards
    ANSI B11:19-1990
    ANSI/RIA R15.06
    EN/IEC 61496-1
    EN/IEC 61496-1-2 for type 4 ESPE
    EN/IEC 61496-2
    OSHA 1910-212
    OSHA 1910-217C
    ROHS directive 2002/95/EC
    Machinery directive 2006/42/EC
    EMC 2004/108/EC
    Work equipment directive 2009/104/EC
    product certifications
    CSA
    TÜV
    UL
    safety level
    Type 4 conforming to IEC 61496-1-2
    Can reach SIL 3 conforming to IEC 61508 (correctly wired)
    Can reach category 4 conforming to EN/ISO 13849-1 (correctly wired)
    Can reach PL = e conforming to EN/ISO 13849-1 (correctly wired)
    safety reliability data
    PFH = 2.7E-9 1/h conforming to IEC 61508 (verified in worst case conf: 6 beams), proof test interval = 20 yr
    ambient air temperature for operation
    0...55 °C
    ambient air temperature for storage
    -25...75 °C
    relative humidity
    0...95 % without condensation
    IP degree of protection
    IP65
    IP67
    shock resistance
    10 gn for 16 ms conforming to IEC 61496-1
    vibration resistance
    0.35 +/- 0.05 mm (f = 10...55 Hz) conforming to IEC 61496-1
    Offer Sustainability
    RoHS (date code: YYWW)
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.