module XPS-PV - hydraulic valves on linear presses - 24 V DC

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety module
    safety module name
    XPSPVT
    safety module application
    For dynamic monitoring of hydraulic valves on linear presses
    function of module
    Monitoring hydraulic valves
    safety level
    Can reach PL e/category 4 conforming to EN/ISO 13849-1
    Can reach SILCL 3 conforming to EN/IEC 62061
    safety reliability data
    MTTFd = 50.9 years conforming to EN/ISO 13849-1
    DC = 0...99 % conforming to EN/ISO 13849-1
    PFHd = 2.24E-8 1/h conforming to EN/IEC 62061
    [Us] rated supply voltage
    24 V DC (- 10...10 %)
    output type
    Relay 2 NO + 1 NC, volt-free
    enclosure type
    Removable
    Complementary
    power consumption in W
    < 6 W
    breaking capacity
    C300 : holding 180 VA AC-15 for relay output
    C300 : inrush 1800 VA AC-15 for relay output
    breaking capacity
    1.5 A / 24 V - L/R = 50 ms, DC-13 for relay output
    output wiping time
    >= 100 ms
    [Ith] conventional free air thermal current
    <= 2.5 A
    associated fuse rating
    4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    response time on input open
    <= 15 ms
    [Ui] rated insulation voltage
    300 V, degree of pollution 2 conforming to IEC 60647-5-1, DIN VDE 0110 part 1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III, conforming to IEC 60647-5-1, DIN VDE 0110 part 1
    local signalling
    8 LEDs
    enclosure material
    Polycarbonate
    number of terminal blocks
    20
    connections - terminals
    Captive screw clamp terminals: 2 x 0.5...2 x 1.5 mm² with cable end
    Captive screw clamp terminals: 2 x 2.5 mm² without cable end
    mounting support
    35 mm symmetrical DIN rail
    depth
    118 mm
    height
    73 mm
    width
    100 mm
    product weight
    0.54 kg
    Environment
    standards
    EN 60204-1
    EN 693
    EN/IEC 60947-5-1
    product certifications
    CSA
    TÜV
    UL
    IP degree of protection
    IP20(terminals) conforming to EN/IEC 60529
    IP40(enclosure) conforming to EN/IEC 60529
    ambient air temperature for operation
    -10...55 °C
    ambient air temperature for storage
    -25...85 °C
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    Preventa safety modules For monitoring hydraulic safety system valves (in linear or eccentric presses) XPSPVT/PVK (Version 1.0)
    Modules de sécurité Preventa pour surveillance de vannes hydrauliques (sur presses linéaires ou excentriques) XPSPVT, XPSPVK (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    XPSPVK PVT Type Examination (Version 1.0)
    Date 1/31/16
    Size 210 KB
    Instruction sheet
    Date
    Size
    Add to My Documents
    XPSPVT1180 Safety module for dynamic monitoring of hydraulic valves on linear presses (Version 08)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Preventa DoC XPSPVK XPSPVT (Version 1.0)
    Date 6/19/18
    Size 530.7 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    XPSOT..., XPSPVK..., XPSPVT... Preventa Safety Relay, Product End-of-Life Instructions (Version 2.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    XPSOT..., XPSPVK..., XPSPVT... Preventa Safety Relay, Product Environmental Profile (Version 2.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.