Global (English)

Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

Schneider Electric XPSMFCIO2401 Image

View all Preventa XPS MF

Preventa XPS MF - XPSMFCIO2401

Modular safety controllers

Schneider Electric XPSMFCIO2401 Image
View all Preventa XPS MF
Preventa XPS MF - XPSMFCIO2401
Modular safety controllers

Prevent a Safety automation - digital output and counting input cards

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Digital output and counting input cards
    safety module name
    XPS MF60
    safety use category
    Category 4 maximum conforming to EN 954-1
    Performance level e conforming to EN/ISO 13849-1
    SIL 3 conforming to EN/IEC 61508
    function of module
    Monitoring incremental encoders counting inputs
    Monitoring safety actuators discrete output
    Monitoring safety dialogue discrete output
    Monitoring sensors 2/3-wire PNP/NPN counting inputs
    standards
    DIN V 0801
    DIN V 19250
    EN 50156 pending
    IEC 61131
    [Us] rated supply voltage
    24 V DC (- 15...20 %)
    group of channels
    1 group of 4 discrete inputs
    2 groups of 4 counting inputs
    counting input number
    2
    discrete output number
    4
    connections - terminals
    Removable screw terminal block, clamping capacity: 2 x 0.5 mm²,AWG 20 flexible with cable end for counting inputs
    Removable screw terminal block, clamping capacity: 2 x 0.5 mm²,AWG 20 flexible with cable end for discrete output
    Removable screw terminal block, clamping capacity: 1 x 0.14...1 x 1.5 mm²,AWG 28...AWG 16 flexible without cable end for counting inputs
    Removable screw terminal block, clamping capacity: 1 x 0.14...1 x 1.5 mm²,AWG 28...AWG 16 flexible without cable end for discrete output
    Removable screw terminal block, clamping capacity: 1 x 0.14...1 x 1.5 mm²,AWG 28...AWG 16 solid without cable end for counting inputs
    Removable screw terminal block, clamping capacity: 1 x 0.14...1 x 1.5 mm²,AWG 28...AWG 16 solid without cable end for discrete output
    Removable screw terminal block, clamping capacity: 1 x 0.25...1 x 0.5 mm²,AWG 22...AWG 20 flexible with cable end for counting inputs
    Removable screw terminal block, clamping capacity: 1 x 0.25...1 x 0.5 mm²,AWG 22...AWG 20 flexible with cable end for discrete output
    Removable screw terminal block, clamping capacity: 1 x 0.25...1 x 1.5 mm²,AWG 22...AWG 16 flexible without cable end for counting inputs
    Removable screw terminal block, clamping capacity: 1 x 0.25...1 x 1.5 mm²,AWG 22...AWG 16 flexible without cable end for discrete output
    Removable screw terminal block, clamping capacity: 2 x 0.14...2 x 0.5 mm²,AWG 28...AWG 20 solid without cable end for counting inputs
    Removable screw terminal block, clamping capacity: 2 x 0.14...2 x 0.5 mm²,AWG 28...AWG 20 solid without cable end for discrete output
    Removable screw terminal block, clamping capacity: 2 x 0.14...2 x 0.75 mm²,AWG 28...AWG 18 flexible without cable end for counting inputs
    Removable screw terminal block, clamping capacity: 2 x 0.14...2 x 0.75 mm²,AWG 28...AWG 18 flexible without cable end for discrete output
    Removable screw terminal block, clamping capacity: 2 x 0.25...2 x 0.34 mm²,AWG 22 flexible without cable end for counting inputs
    Removable screw terminal block, clamping capacity: 2 x 0.25...2 x 0.34 mm²,AWG 22 flexible without cable end for discrete output
    Complementary
    marking
    CE
    internal resistance
    3.7 kOhm for counting circuit
    counting input voltage
    24 V DC
    5 V DC
    counting input current
    <= 3 mA
    counting frequency
    <= 1 MHz
    counter inputs resolution
    24 bits
    time base accuracy
    0,002
    cable distance between devices
    <= 500 mm counting inputs
    discrete output voltage
    18.4...26.8 V DC
    discrete output current
    <= 2 mA (per channel)
    2 A (per card)
    0.5 A (per channel)
    voltage drop
    <= 3 V at 0.5 A for discrete output
    minimum load
    2 mA per discrete output
    number of terminal blocks
    1 for discrete output
    2 for counting inputs
    current consumption
    0.1 A 3.3 V DC rack
    0.1 A 5 V DC rack
    0.8 A 24 V DC power supply
    product weight
    0.26 kg
    Environment
    product certifications
    CSA
    C-Tick
    TÜV
    UL
    IP degree of protection
    IP20 with covering plate on unused in rack I/O card slots
    ambient air temperature for operation
    0...60 °C conforming to EN/IEC 61131-2
    ambient air temperature for storage
    -40...85 °C conforming to EN/IEC 61131-2
    relative humidity
    95 % (supply not connected)
    operating altitude
    < 2000 m
    pollution degree
    2
    electrical shock protection class
    Class II conforming to IEC 61131-2
    electromagnetic compatibility
    EN/IEC 61131-2
    vibration resistance
    1 gn (f = 10...150 Hz) conforming to EN 61131-2 (10 cycles per axis)
    shock resistance
    15 gn for 11 ms (2 cycles per axis), conforming to EN 61131-2
    resistance to electrostatic discharge
    4 kV contact conforming to EN/IEC 61000-4-2
    8 kV on air conforming to EN/IEC 61000-4-2
    resistance to electromagnetic fields
    10 V/m (26...1000 MHz), amplitude modulation 80 % conforming to EN/IEC 61000-4-3
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • French
    • Italian
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    Date 2/3/17
    Size 3.8 MB
    Date 2/3/17
    Size 4.2 MB
    User guide
    Date
    Size
    Add to My Documents
    Date 10/18/12
    Size 4.2 MB
    Date 9/30/11
    Size 4.2 MB
    Date 10/18/12
    Size 5.1 MB
    Date 10/18/12
    Size 4.2 MB
    Date 10/18/12
    Size 5 MB
    Date 1/7/15
    Size 2.6 MB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions
    Front View


    Max. module depth including screw terminals for the power supply: 239 mm/ 9.21 in.


  • Mounting and Clearance

    Mounting
    Air Circulation


    Minimum clearances



  • Connections and Schema

    Actuator Connections to the Outputs