Characteristics
Main range of product Preventa Safety automationproduct or component type Preventa safety PLC compactsafety module name XPSMF31safety module application For numerous machine safety functions and for the protection of personnelsafety use category Category 4 conforming to EN 954-1/ISO 13849-1SIL 3 conforming to IEC 61508structure type 10BASE-T/100BASE-TX Modbus TCP/IP10BASE-T/100BASE-TX safe EthernetComplementary function of module Monitoring safety actuators for discrete outputMonitoring safety detection for discrete inputMonitoring safety dialogue for discrete inputMonitoring safety dialogue for discrete output[Us] rated supply voltage 24 V DC (- 15...20 %)no load current 0.4 Aprotection type Internal fuseclock With, supplied by backup capacitor for 1 week following loss of supplyresponse time Depending on size of applicationmemory description User logic 250 kB for applicationUser logic 250 kB for datadiscrete input number 20, not isolatedvoltage state 0 guaranteed <= 5 V for discrete inputvoltage state 1 guaranteed >= 15 V for discrete inputcurrent state 0 guaranteed 1...1.5 mA, discrete inputcurrent state 1 guaranteed >= 2 mA, discrete inputdiscrete input voltage 20 Vdiscrete input current 100 mAinput protection type Protected against short-circuit to earthProtected against short-circuitinput overvoltage protection 500 V for discrete input IEC 61000-4-5switching voltage 7.5 Vdiscrete output number 8discrete output voltage 24 V DCoutput voltage tolerance +/- 2 %discrete output current <= 7 mA (all channels)1 A at 60 °C (channels 4 and 8)2 A at 50 °C (channels 4 and 8)0.5 A at 60 °C (channels 1 to 3 and 5 to 7)minimum load 2 mA per discrete outputleakage current <= 1 mA, at 2 V at state 0 for discrete outputoverload protection Shutdown of outputs concerned with cyclic reconnectioncommunication port protocol Safe Ethernet with 4 RJ45 port(s), transmission rate: 100 Mbps, medium: dual twisted pair cableexchange mode Half duplex, full duplex, autonegotiation Modbus TCP/IPHalf duplex, full duplex, autonegotiation safe Ethernetmethod of access Slave Modbus TCP/IPconcept Transparent Ready Modbus TCP/IPweb server Class A10 Modbus TCP/IPweb services Modbus identification request Modbus TCP/IPModbus TCP/IP messaging (reading/writing of data words) Modbus TCP/IPModbus TCP/IP server Modbus TCP/IPStandard 502 Modbus TCP/IPoperating distance <= 100 m (between station) discrete input<= 100 m (between station) discrete outputnumber of terminal blocks 1 for power supply2 for discrete output5 for discrete inputconnections - terminals Captive screw clamp terminals, clamping capacity: 2 x 0.5 mm²,AWG 20 flexible with cable end for discrete input/output circuitCaptive screw clamp terminals, clamping capacity: 1 x 0.14...1 x 1.5 mm²,AWG 28...AWG 16 flexible without cable end for discrete input/output circuitCaptive screw clamp terminals, clamping capacity: 1 x 0.14...1 x 1.5 mm²,AWG 28...AWG 16 solid without cable end for discrete input/output circuitCaptive screw clamp terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm²,AWG 24...AWG 12 flexible without cable end for power supplyCaptive screw clamp terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm²,AWG 24...AWG 12 solid without cable end for power supplyCaptive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 0.5 mm²,AWG 22...AWG 20 flexible with cable end for discrete input/output circuitCaptive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 1.5 mm²,AWG 22...AWG 16 flexible without cable end for discrete input/output circuitCaptive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 2.5 mm²,AWG 22...AWG 16 flexible with cable end for power supplyCaptive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 2.5 mm²,AWG 22...AWG 16 flexible without cable end for power supplyCaptive screw clamp terminals, clamping capacity: 2 x 0.14...2 x 0.5 mm²,AWG 28...AWG 20 solid without cable end for discrete input/output circuitCaptive screw clamp terminals, clamping capacity: 2 x 0.14...2 x 0.75 mm²,AWG 28...AWG 18 flexible without cable end for discrete input/output circuitCaptive screw clamp terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm²,AWG 24...AWG 12 flexible without cable end for power supplyCaptive screw clamp terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm²,AWG 24...AWG 12 solid without cable end for power supplyCaptive screw clamp terminals, clamping capacity: 2 x 0.25...2 x 0.34 mm²,AWG 22 flexible without cable end for discrete input/output circuitCaptive screw clamp terminals, clamping capacity: 2 x 0.25...2 x 1 mm²,AWG 22...AWG 18 flexible without cable end for power supplyCaptive screw clamp terminals, clamping capacity: 2 x 0.5...2 x 1.5 mm²,AWG 22...AWG 16 flexible with cable end for power supplytightening torque 0.22...0.25 N.mwire stripping length 9 mmcurrent consumption 8 A at 24 V DC on power supplymounting support 35 mm symmetrical DIN raildepth 66.5 mmheight 113 mmwidth 253 mmproduct weight 1 kgEnvironment standards DIN V 0801DIN V 19250EN 50156 pendingIEC 61131immunity to microbreaks 10 msIP degree of protection IP20 (enclosure)ambient air temperature for operation 0...60 °C conforming to EN 61131-2ambient air temperature for storage -40...85 °C conforming to EN 61131-2relative humidity 95 % (supply not connected)operating altitude < 2000 mpollution degree 2electrical shock protection class Class II conforming to EN/IEC 61131-2electromagnetic compatibility EN/IEC 61131-2vibration resistance 1 gn (f = 10...150 Hz) conforming to EN 61131-2shock resistance 15 gn for 11 ms conforming to EN 61131-2resistance to electrostatic discharge 4 kV contact conforming to EN/IEC 61000-4-28 kV on air conforming to EN/IEC 61000-4-2resistance to electromagnetic fields 10 V/m (26...1000 MHz), conforming to EN/IEC 61000-4-3Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- Portuguese
- French
- Italian
- German
CatalogueSizeAdd to My DocumentsAutomates compacts de sécurité Preventa XPSMF40, XPSMF31/30/35 (Version 1.0)Preventa Safety compacts PLCs Type XPSMF40, XPSMF31/30/35 (Version 1.0)User guideSizeAdd to My DocumentsXPSMFWIN Manual de software (Version 02)XPSMFWIN Manuale del software (Version 02)XPSMF•• Automates de sécurité - Modbus TCP/IP, Guide de démarrage rapide (Version 01)Date 10/18/12Size 551 KBCertificateSizeAdd to My DocumentsUL_E219270_NRAQ_NRAQ7_JUN2018 (Version 1.0) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Presentation
Housing ElementsFront ViewNo.
Description
1
power supply input
2
digital outputs
3
digital inputs
4
indicators
Top ViewBottom View -
Dimensions Drawings
DimensionsFront ViewSide View -
Mounting and Clearance
MountingMinimum ClearancesAir CirculationNo.
Description
1
The height of the cable ducts is less than 40 mm / 1.57 in.
2
The height of the cable ducts is greater than 40 mm / 1.57 in.
L = H - 40 mm / 1.57 in.
L = length of the spacer
H = height of the cable duct
Minimum clearance when H > 40 mm/1.57 in. and no spacer
Mounting Precautions Relating to ConnectorsAccess to Modbus Serial Link (RTU)SUB-D 9-pin connector
(1)minimum valueAdaptor XPS MFADAPT
(1)minimum valueAccess to PROFIBUS DPAccess to Ethernet Network(1)minimum value -
Connections and Schema
Wiring DiagramsEmergency Stop Connections (Line Control)Actuator Connections to the Outputs