Global (English)

Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

Schneider Electric XPSMF3022 Image

View all Preventa XPS MF

Preventa XPS MF - XPSMF3022

Compact safety controllers

Schneider Electric XPSMF3022 Image
View all Preventa XPS MF
Preventa XPS MF - XPSMF3022
Compact safety controllers

Preventa safety PLC compact - 20 I not isolated

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety PLC compact
    safety module name
    XPSMF30
    safety module application
    For numerous machine safety functions and for the protection of personnel
    safety use category
    Category 4 conforming to EN 954-1/ISO 13849-1
    SIL 3 conforming to IEC 61508
    structure type
    10BASE-T/100BASE-TX Modbus TCP/IP
    10BASE-T/100BASE-TX safe Ethernet
    Complementary
    function of module
    Monitoring safety actuators for discrete output
    Monitoring safety detection for discrete input
    Monitoring safety dialogue for discrete input
    Monitoring safety dialogue for discrete output
    [Us] rated supply voltage
    24 V DC (- 15...20 %)
    no load current
    0.5 A
    protection type
    Internal fuse
    clock
    With, supplied by backup capacitor for 1 week following loss of supply
    response time
    Depending on size of application
    memory description
    User logic 250 kB for application
    User logic 250 kB for data
    discrete input number
    20, not isolated
    voltage state 0 guaranteed
    <= 5 V for discrete input
    voltage state 1 guaranteed
    >= 15 V for discrete input
    current state 0 guaranteed
    1.25...1.5 mA, discrete input
    current state 1 guaranteed
    >= 2 mA, discrete input
    discrete input voltage
    20 V
    discrete input current
    100 mA
    input protection type
    Protected against short-circuit to earth
    Protected against short-circuit
    input overvoltage protection
    500 V for discrete input IEC 61000-4-5
    switching voltage
    7.5 V
    discrete output number
    8
    discrete output voltage
    24 V DC
    output voltage tolerance
    +/- 2 %
    discrete output current
    <= 7 mA (all channels)
    1 A at 60 °C (channels 4 and 8)
    2 A at 50 °C (channels 4 and 8)
    0.5 A at 60 °C (channels 1 to 3 and 5 to 7)
    minimum load
    2 mA per discrete output
    leakage current
    <= 1 mA, at 2 V at state 0 for discrete output
    overload protection
    Shutdown of outputs concerned with cyclic reconnection
    communication port protocol
    Modbus TCP/IP with 4 RJ45 port(s), transmission rate: 100 Mbps, 10 Mbps, medium: dual twisted pair cable, category 5D or better
    Safe Ethernet with 4 RJ45 port(s), transmission rate: 100 Mbps, 10 Mbps, medium: dual twisted pair cable, category 5D or better
    exchange mode
    Half duplex, full duplex, autonegotiation Modbus TCP/IP
    Half duplex, full duplex, autonegotiation safe Ethernet
    method of access
    Slave Modbus TCP/IP
    concept
    Transparent Ready Modbus TCP/IP
    web server
    Class A10 Modbus TCP/IP
    web services
    Modbus identification request Modbus TCP/IP
    Modbus TCP/IP messaging (reading/writing of data words) Modbus TCP/IP
    Modbus TCP/IP server Modbus TCP/IP
    Standard 502 Modbus TCP/IP
    operating distance
    <= 100 m (between station) discrete input
    <= 100 m (between station) discrete output
    number of terminal blocks
    1 for power supply
    2 for discrete output
    5 for discrete input
    connections - terminals
    Captive screw clamp terminals, clamping capacity: 2 x 0.5 mm²,AWG 20 flexible with cable end for discrete input/output circuit
    Captive screw clamp terminals, clamping capacity: 1 x 0.14...1 x 1.5 mm²,AWG 28...AWG 16 flexible without cable end for discrete input/output circuit
    Captive screw clamp terminals, clamping capacity: 1 x 0.14...1 x 1.5 mm²,AWG 28...AWG 16 solid without cable end for discrete input/output circuit
    Captive screw clamp terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm²,AWG 24...AWG 12 flexible without cable end for power supply
    Captive screw clamp terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm²,AWG 24...AWG 12 solid without cable end for power supply
    Captive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 0.5 mm²,AWG 22...AWG 20 flexible with cable end for discrete input/output circuit
    Captive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 1.5 mm²,AWG 22...AWG 16 flexible without cable end for discrete input/output circuit
    Captive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 2.5 mm²,AWG 22...AWG 16 flexible with cable end for power supply
    Captive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 2.5 mm²,AWG 22...AWG 16 flexible without cable end for power supply
    Captive screw clamp terminals, clamping capacity: 2 x 0.14...2 x 0.5 mm²,AWG 28...AWG 20 solid without cable end for discrete input/output circuit
    Captive screw clamp terminals, clamping capacity: 2 x 0.14...2 x 0.75 mm²,AWG 28...AWG 18 flexible without cable end for discrete input/output circuit
    Captive screw clamp terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm²,AWG 24...AWG 12 flexible without cable end for power supply
    Captive screw clamp terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm²,AWG 24...AWG 12 solid without cable end for power supply
    Captive screw clamp terminals, clamping capacity: 2 x 0.25...2 x 0.34 mm²,AWG 22 flexible without cable end for discrete input/output circuit
    Captive screw clamp terminals, clamping capacity: 2 x 0.25...2 x 1 mm²,AWG 22...AWG 18 flexible without cable end for power supply
    Captive screw clamp terminals, clamping capacity: 2 x 0.5...2 x 1.5 mm²,AWG 22...AWG 16 flexible with cable end for power supply
    tightening torque
    0.22...0.25 N.m
    wire stripping length
    9 mm
    current consumption
    8 A at 24 V DC on power supply
    mounting support
    35 mm symmetrical DIN rail
    depth
    66.5 mm
    height
    113 mm
    width
    253 mm
    product weight
    1.2 kg
    Environment
    standards
    DIN V 0801
    DIN V 19250
    EN 50156 pending
    IEC 61131
    immunity to microbreaks
    10 ms
    IP degree of protection
    IP20 (enclosure)
    ambient air temperature for operation
    0...60 °C conforming to EN 61131-2
    ambient air temperature for storage
    -40...85 °C conforming to EN 61131-2
    relative humidity
    95 % (supply not connected)
    operating altitude
    < 2000 m
    pollution degree
    2
    electrical shock protection class
    Class II conforming to EN/IEC 61131-2
    electromagnetic compatibility
    EN/IEC 61131-2
    vibration resistance
    1 gn (f = 10...150 Hz) conforming to EN 61131-2
    shock resistance
    15 gn for 11 ms conforming to EN 61131-2
    resistance to electrostatic discharge
    4 kV contact conforming to EN/IEC 61000-4-2
    8 kV on air conforming to EN/IEC 61000-4-2
    resistance to electromagnetic fields
    10 V/m (26...1000 MHz), conforming to EN/IEC 61000-4-3
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • French
    • Italian
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    User guide
    Date
    Size
    Add to My Documents
    Date 10/18/12
    Size 4.2 MB
    Date 9/30/11
    Size 4.2 MB
    Date 10/18/12
    Size 5.1 MB
    Date 10/18/12
    Size 4.2 MB
    Date 10/18/12
    Size 5 MB
    CAD
    Date
    Size
    Add to My Documents
    CAD files for XPSMF Preventa PES.
    Certificate
    Date
    Size
    Add to My Documents
    Date 9/6/18
    Size 104.4 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Presentation

    Housing Elements
    Front View


    No.

    Description

    1

    digital outputs

    2

    digital inputs

    3

    indicators

    4

    Ethernet connections

    5

    field bus connections

    6

    power supply input

    Top View


    Bottom View



  • Dimensions Drawings

    Dimensions
    Front View


    Side View



  • Mounting and Clearance

    Mounting
    Minimum Clearances


    Air Circulation


    No.

    Description

    1

    The height of the cable ducts is less than 40 mm / 1.57 in.

    2

    The height of the cable ducts is greater than 40 mm / 1.57 in.

    L = H - 40 mm / 1.57 in.

    L = length of the spacer

    H = height of the cable duct

    Minimum clearance when H > 40 mm/1.57 in. and no spacer



    Mounting Precautions Relating to Connectors
    Access to Modbus Serial Link (RTU)

    SUB-D 9-pin connector


    (1)
    minimum value

    Adaptor XPS MFADAPT


    (1)
    minimum value

    Access to PROFIBUS DP


    Access to Ethernet Network


    (1)
    minimum value


  • Connections and Schema

    Wiring Diagrams
    Emergency Stop Connections (Line Control)


    Actuator Connections to the Outputs