View all
Preventa XPS MP, XPS MC, XPS MCM
Preventa XPS MP, XPS MC, XPS MCM - XPSMCMEN0200TT
Modular safety controllers

View all
Preventa XPS MP, XPS MC, XPS MCM
Preventa XPS MP, XPS MC, XPS MCM
-
XPSMCMEN0200TT
Modular safety controllers

Speed monitoring 2 TTL encoder expansion module with screw term
Show more characteristics >-
Characteristics
Main range of product Preventa Safety automationproduct or component type Safe speed monitoring moduledevice short name XPSMCMelectrical connection Screw terminal[Us] rated supply voltage 24 V (- 20...20 %) DCdiscrete input voltage 24 V DCfunction of module Speed monitoringComplementary power consumption in W <= 3 Wpower dissipation in W 3 Wintegrated connection type Backplane expansion bussafety level SILCL 3 conforming to IEC 62061Can reach category 4 conforming to EN/ISO 13849-1Can reach PL = e conforming to EN/ISO 13849-1Type 4 conforming to EN/IEC 61496-1quality labels CEnumber of terminal blocks 4local signalling 1 LED green with PWR marking for power ON1 LED green with RUN marking for RUN (status)1 LED red with E IN marking for internal error1 LED red with E EX marking for external error2 LEDs orange with ADDR marking for node address2 LEDs yellow with PROX marking for proximity sensors connection status2 LEDs yellow with SH marking for speed monitoring status2 LEDs yellow with ENC marking for encoder connection statusconnections - terminals 2-wire captive screw clamp terminals, removable terminal block1-wire captive screw clamp terminals, removable terminal blockinput frequency <= 5 kHz for sensor<= 500 kHz for encoder TTLsensor type Inductive proximity sensorelectrical connection 1 connector RJ45 conforming to EIA/TIA-568-Acable cross section (0.2...2.5 mm² flexible cable without cable end(0.2...2.5 mm² solid cable without cable end(0.25...2.5 mm² flexible cable with cable end, with bezel(0.25...2.5 mm² flexible cable with cable end, without bezel(0.2...1.5 mm² flexible cable without cable end(0.25...1 mm² flexible cable with cable end, without bezel(0.5...1.5 mm² flexible cable with cable end, with double bezel(0.2...1 mm² solid cable without cable endmounting support Omega 35 mm DIN rail conforming to EN 50022depth 22.5 mmheight 99 mmwidth 114.5 mmproduct weight 0.3 kgEnvironment standards EN/IEC 61496-1EN/IEC 61508EN/IEC 61800-5-1EN/ISO 13849-1IEC 62061product certifications cULusTÜVRCMIP degree of protection IP20 for enclosureambient air temperature for operation -10...55 °Cambient air temperature for storage -20...85 °Crelative humidity 10...95 %pollution degree 2[Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 61800-5insulation 250 V AC between power supply and housing conforming to EN/IEC 61800-5-1overvoltage category IIelectromagnetic compatibility Electrostatic discharge immunity test - test level 6 kV, on contact conforming to EN/IEC 61000-4-2Electrostatic discharge immunity test - test level 20 kV, on air conforming to EN/IEC 61000-4-2Susceptibility to electromagnetic fields - test level 10 V/m, 80...1000 MHz conforming to EN/IEC 61000-4-3Susceptibility to electromagnetic fields - test level 30 V/m, 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3vibration resistance +/-0.35 mm (f = 10...55 Hz) conforming to EN/IEC 61496-1shock resistance 10 gn (duration = 16 ms) shocks : 1000 shocks on each axis EN/IEC 61496-1service life 20 yrOffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile AvailableProduct end of life instructions Available -
Documents and Downloads
Language- English
- Spanish
- Portuguese
- French
- Italian
- Chinese
- German
- Turkish
CatalogueSizeAdd to My DocumentsModular safety controllers Preventa XPSMCM (Version 3.1)Contrôleurs de sécurité modulaires Preventa XPSMCM (Version 2.0)CADSizeAdd to My DocumentsCAD files for XPSMCMEN0200TT: XPSMCM Expansion module for safety speed monitoring upto 2 TTL inputs with screw terminal. (Version 1.0)Date 2/7/19Size 107.6 KBCertificateSizeAdd to My DocumentsInstruction sheetSizeAdd to My DocumentsXPSMCMEN. Expansion Modules, Instruction Sheet (Version 01)XPSMCMEN. Erweiterungsmodule, Kurzanleitung (Version 01)XPSMCMEN. Genişletme Modülleri, Yönerge Sayfası (Version 01)XPSMCMEN. Moduli di espansione, Scheda di istruzioni (Version 01)XPSMCMEN. Módulos de expansão, Planilha de instruções (Version 01)XPSMCMEN. Modules d’extension, Fiche d’instructions (Version 01)XPSMCMEN. Módulos de ampliación, Hoja de instrucciones (Version 01)Declaration of conformitySizeAdd to My DocumentsXPSMCM Preventa Modular Safety Controller DoC (Version 1.2) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
DimensionsScrew Terminal -
Mounting and Clearance
Mounting Safety Controller CPU with Module(s)Mount BackPlane Connector on Rail1 :Connect as much Backplane Connector as module to be install.2 :Fix the connectors to the rail (Top first).Mount Safety Controller CPU with Other Module(s)1 :Mount controller CPU and modules on rail.2 :Make sure that the controller CPU or the module(s) are plugged on the BackPlane connector. -
Connections and Schema
WiringTerminal DesignationTerminal
Signal
Description
1
24 VDC
24 VDC power supply
2
NODE_ADDR0
Node selection
3
NODE_ADDR1
4
0 VDC
0 Vdc power supply
5
PROXY1_24V
PROXIMITY 1 connections
6
PROXY1_REF
7
PROXY1_NO
8
PROXY1_NC
9
PROXY2_24V
PROXIMITY 2 connections
10
PROXY2_REF
11
PROXY2_NO
12
PROXY2_NC
13
not connected
not connected
14
15
16