Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Preventa XPS MP, XPS MC, XPS MCM
Schneider Electric XPSMC32ZPPACK Image

XPSMC32ZPPACK

Schneider Electric XPSMC32ZPPACK Image
XPSMC32ZPPACK

safety controller XPS-MC - 24 V DC - 32 input - 48 LEDs signalling

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Kit configurable safety controller
    safety module name
    XPSMC
    safety use category
    Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1
    PLE maximum conforming to EN/ISO 13849-1
    SIL 3 maximum conforming to IEC 61508
    type of start
    Configurable
    standards
    EN 574/ISO 13851
    EN/IEC 60204-1
    IEC 61508
    EN 954-1/EN/ISO 13849-1
    EN/IEC 60947-5-1
    EN 1760-1/ISO 13856-1
    EN/IEC 61496-1
    product certifications
    TÜV
    UL
    CSA
    [Us] rated supply voltage
    24 V DC - 20...20 %
    number of inputs
    32
    communication port protocol
    Modbus with 1 RJ45 port(s), serial link, transmission rate: 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
    Profibus with 1 SUB-D 9-pin female port(s), serial link, transmission rate: 12 Mbps
    safety level
    Can reach PL e/category 4 conforming to EN 954-1/EN/ISO 13849-1
    Can reach SIL 3 conforming to IEC 61508
    Complementary
    kit composition
    Connection cable
    Set of cage clamp terminals
    Printed packaging label 80 x 50 mm
    VDE slot screwdriver 2.5 x 75 mm
    Packaging small model for software configuration
    Set of screw terminals
    Configuration software
    USB/RS485 converter
    Ethernet cable 2m
    Profibus connectors
    Safety controller
    function of module
    Dynamic monitoring of hydraulic valves on linear presses
    Eccentric press
    Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring
    Enabling switch monitoring, 2 or 3 contacts
    Foot switch monitoring
    Guard monitoring for injection presses and blowing machines
    Guard monitoring with 1 or 2 limit switches
    Hydraulic press
    Magnetic switch monitoring
    Monitoring safety stop at top dead centre on eccentric press
    Muting function of light curtains
    Position selector
    Safety mat monitoring
    Safety time delays
    Shaft/chain breaking monitor
    Zero speed detection
    Light curtain monitoring category 4 conforming to EN/IEC 61496
    Two-hand control category 3 conforming to EN 574/ISO 13851
    synchronisation time between inputs
    Depending on configuration selected
    power consumption in W
    12 W
    input protection type
    External fuse 16 A
    [Uc] control circuit voltage
    28.8 V
    maximum line resistance
    100 Ohm <2000 m
    output type
    2 relays, 2 NO contacts (4 NO total) circuit(s)
    Solid state, 6 circuit(s), volt-free
    breaking capacity
    180 VA holding AC-15 C300 relay output
    1800 VA inrush AC-15 C300 relay output
    breaking capacity
    2 A at 24 V for static output circuit
    1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
    output thermal current
    4 A for both outputs simultaneously
    6 A for 1 output and 2 A for the other for relay output
    [Ith] conventional free air thermal current
    16 A for relay output
    6.5 A for static output circuit
    associated fuse rating
    16 A gL for power supply
    4 A gL for relay output
    6 A fast blow for relay output
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    response time
    Configurable : 20 ms or 30 ms with software XPSMCWIN
    [Ui] rated insulation voltage
    300 V (pollution degree 2) conforming to IEC 60647-5-1, DIN VDE 0110 part 1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to IEC 60647-5-1, DIN VDE 0110 part 1
    method of access
    Slave
    exchange size
    14 words
    number of addresses
    1…125 for Profibus
    1…247 for Modbus
    parity
    Even for Modbus
    No for Modbus
    Odd for Modbus
    data format
    1 start bit/8 data bits
    1 stop bit even or odd
    2 stop bits without parity
    RTU (Remote Terminal Unit) mode
    supported modbus function
    01: 8-bit output data/32-bit input data
    02: 32-bit input data/8-bit output data
    03: information and errors
    local signalling
    48 LEDs
    mounting support
    Mounting plate
    depth
    153 mm
    height
    151.5 mm
    width
    74 mm
    net weight
    0.84 kg
    Environment
    IP degree of protection
    IP20 conforming to EN/IEC 60529
    ambient air temperature for operation
    -10…55 °C
    ambient air temperature for storage
    -25…85 °C
    Contractual warranty
    Warranty
    18 months
  • Documents

    Language
    • English
    • French
    Catalogue
    Date
    Size
    Add to My Documents
    Preventa safety configurable controllers XPSMC (Version 1.0)
    Contrôleurs configurables de sécurité Preventa XPSMC (Version 1.0)
    End of Life Information
    Date
    Size
    Add to My Documents
    XPSMC... Preventa Safety Controller, Product End-of-Life Instructions (Version 2.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    XPSMC... Preventa Safety Controller, Product Environmental Profile (Version 2.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    1
    When using XPSMCTS• connectors this dimension is 153 mm (6.02 in)
    When using XPSMCTC• connectors this dimension is 151,5 mm (5.96 in)


  • Mounting and Clearance

    Installation


    Metal adaptor for fixing on metal: DIN rail 35 mm/1.38 in.


  • Connections and Schema

    Wiring Diagrams
    Refer to the Instruction Sheet

    To download the instruction sheet, follow below procedure:


    1
    Click on Download & Documents.
    2
    Click on Instruction sheet.


  • Technical Description

    Safety Functions


    • Emergency stop monitoring with time delay:

      • 1 channel wiring, with automatic start.

      • 2 channel wiring, with start button.


    • Emergency stop monitoring without time delay:

      • 1 channel wiring, with automatic start.

      • 2 channel wiring, with start button.


    • Two-hand control.


    • Guard monitoring:

      • with 1 limit switch.

      • with 2 limit switches.

      • with 2 limit switches, with guard locking.

    • Guard monitoring for injection presses and blowing machines.


    • Magnetic switch monitoring.


    • Sensing mat monitoring.


    • Light curtains monitoring:

      • Relay output type.

      • Solid-state output type.

    • “Muting” function for light curtains.


    • Zero speed detection.


    • Dynamic monitoring of hydraulic valves on linear presses.


    • Safety time delays.


    • Monitoring safety stop at top dead centre on eccentric press.

    • Hydraulic press.

    • Eccentric press.


    • Enabling switching monitoring:

      • 2 contact type.

      • 3 contact type.

    Other functions:

    • Foot switch monitoring

    • Chain shaft breakage monitoring

    • Position selector


Compare products: /