Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Configurable safety controller
    safety module name
    XPSMC
    safety use category
    Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1
    PLE maximum conforming to EN/ISO 13849-1
    SIL 3 maximum conforming to IEC 61508
    type of start
    Configurable
    standards
    EN 1760-1/ISO 13856-1
    EN 574/ISO 13851
    EN 954-1/EN/ISO 13849-1
    EN/IEC 60204-1
    EN/IEC 60947-5-1
    EN/IEC 61496-1
    IEC 61508
    product certifications
    CSA
    TÜV
    UL
    [Us] rated supply voltage
    24 V DC - 20...20 %
    number of inputs
    16
    communication port protocol
    Modbus with 1 RJ45 port(s), serial link, transmission rate: 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
    Profibus with 1 SUB-D 9-pin female port(s), serial link, transmission rate: 12 Mbps
    safety level
    Can reach PL e/category 4 conforming to EN 954-1/EN/ISO 13849-1
    Can reach SIL 3 conforming to IEC 61508
    Complementary
    function of module
    Dynamic monitoring of hydraulic valves on linear presses
    Eccentric press
    Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring
    Enabling switch monitoring, 2 or 3 contacts
    Foot switch monitoring
    Guard monitoring for injection presses and blowing machines
    Guard monitoring with 1 or 2 limit switches
    Hydraulic press
    Magnetic switch monitoring
    Monitoring safety stop at top dead centre on eccentric press
    Muting function of light curtains
    Position selector
    Safety mat monitoring
    Safety time delays
    Shaft/chain breaking monitor
    Zero speed detection
    Light curtain monitoring (category 4) conforming to EN/IEC 61496
    Two-hand control (category 3) conforming to EN 574/ISO 13851
    synchronisation time between inputs
    Depending on configuration selected
    power consumption in W
    12 W
    input protection type
    External fuse 16 A
    [Uc] control circuit voltage
    28.8 V
    line resistance
    100 Ohm 2000 m
    output type
    2 relays, 2 NO contacts (4 NO total) circuit(s)
    Solid state, 6 circuit(s), volt-free
    breaking capacity
    C300 : holding 180 VA AC-15 for relay output
    C300 : inrush 1800 VA AC-15 for relay output
    breaking capacity
    1.5 A / 24 V - L/R = 50 ms, DC-13 for relay output
    2 A / 24 V for static output circuit
    output thermal current
    4 A for both outputs simultaneously
    6 A for 1 output and 2 A for the other for relay output
    [Ith] conventional free air thermal current
    <= 16 A for relay output
    <= 6.5 A for static output circuit
    associated fuse rating
    16 A gL for power supply
    4 A gL for relay output
    6 A fast blow for relay output
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    response time
    Configurable : 20 ms or 30 ms with software XPSMCWIN
    [Ui] rated insulation voltage
    300 V, degree of pollution 2 conforming to IEC 60647-5-1, DIN VDE 0110 part 1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to IEC 60647-5-1, DIN VDE 0110 part 1
    method of access
    Slave
    exchange size
    14 words
    number of addresses
    1...247 for Modbus
    1...125 for Profibus
    parity
    Even for Modbus
    No for Modbus
    Odd for Modbus
    data format
    1 start bit/8 data bits
    1 stop bit even or odd
    2 stop bits without parity
    RTU (Remote Terminal Unit) mode
    supported modbus function
    01: 8-bit output data/32-bit input data
    02: 32-bit input data/8-bit output data
    03: information and errors
    local signalling
    32 LEDs
    mounting support
    Mounting plate
    depth
    153 mm
    height
    151.5 mm
    width
    74 mm
    product weight
    0.82 kg
    Environment
    IP degree of protection
    IP20 conforming to EN/IEC 60529
    ambient air temperature for operation
    -10...55 °C
    ambient air temperature for storage
    -25...85 °C
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • French
    • Italian
    • Chinese
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    Preventa safety configurable controllers XPSMC (Version 1.0)
    Contrôleurs configurables de sécurité Preventa XPSMC (Version 1.0)
    User guide
    Date
    Size
    Add to My Documents
    XPSMC... Modifications apportées au manuel utilisateur (Version 01)
    XPSMC... Modifications apportées au manuel utilisateur (Version 01)
    XPSMCWIN Software de Configuração para XPSMC (Version 05)
    XPSMCWIN Configuration Software for XPSMC (Version 05)
    XPSMC... Controladores de segurança, Manual do Hardware (Version 07)
    XPSMC... monitor de seguridad, Manual del hardware (Version 07)
    XPSMCWIN Software di configurazione per XPSMC (Version 05)
    XPSMC... Modifications apportées au manuel utilisateur (Version 01)
    XPSMC... configuratori di sicurezza, Manuale hardware (Version 07)
    XPSMC... Sicherheitscontrollers, Handbuch zur Hardware (Version 07)
    XPSMCWIN Software de configuración para XPSMC (Version 05)
    XPSMC... Modifications apportées au manuel utilisateur (Version 01)
    XPSMC... Modifications apportées au manuel utilisateur (Version 01)
    XPSMCWIN Konfigurationssoftware für XPSMC (Version 05)
    XPSMCWIN Logiciel de configuration du contrôleur XPSMC (Version 05)
    XPSMC... Contrôleur de sécurité, Manuel du matériel (Version 07)
    CAD
    Date
    Size
    Add to My Documents
    CAD for XPSMC16ZP: safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    CCC_2007010303245140_Certificate_XPSMC_valid_20240423 (Version 1.1)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Type XPS-MC, EC Declaration of conformity (Version 1.0)
    End of Life Information
    Date
    Size
    Add to My Documents
    XPSMC... Preventa Safety Controller, Product End-of-Life Instructions (Version 2.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    XPSMC... Preventa Safety Controller, Product Environmental Profile (Version 2.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    1
    When using XPSMCTS• connectors this dimension is 153 mm (6.02 in)
    When using XPSMCTC• connectors this dimension is 151,5 mm (5.96 in)


  • Mounting and Clearance

    Installation


    Metal adaptor for fixing on metal: DIN rail 35 mm/1.38 in.


  • Connections and Schema

    Wiring Diagrams
    Refer to the Instruction Sheet

    To download the instruction sheet, follow below procedure:


    1
    Click on Download & Documents.
    2
    Click on Instruction sheet.


  • Technical Description

    Safety Functions


    • Emergency stop monitoring with time delay:

      • 1 channel wiring, with automatic start.

      • 2 channel wiring, with start button.


    • Emergency stop monitoring without time delay:

      • 1 channel wiring, with automatic start.

      • 2 channel wiring, with start button.


    • Two-hand control.


    • Guard monitoring:

      • with 1 limit switch.

      • with 2 limit switches.

      • with 2 limit switches, with guard locking.

    • Guard monitoring for injection presses and blowing machines.


    • Magnetic switch monitoring.


    • Sensing mat monitoring.


    • Light curtains monitoring:

      • Relay output type.

      • Solid-state output type.

    • “Muting” function for light curtains.


    • Zero speed detection.


    • Dynamic monitoring of hydraulic valves on linear presses.


    • Safety time delays.


    • Monitoring safety stop at top dead centre on eccentric press.

    • Hydraulic press.

    • Eccentric press.


    • Enabling switching monitoring:

      • 2 contact type.

      • 3 contact type.

    Other functions:

    • Foot switch monitoring

    • Chain shaft breakage monitoring

    • Position selector