module XPS-CM - single-beam photo-electric sensors - 24 V DC

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Preventa Safety detection
    product or component type
    Safety module
    safety module name
    XPSCM
    safety module application
    For monitoring of single beam photo-electric sensor
    function of module
    Built-in muting
    safety level
    Can reach category 2 conforming to EN/ISO 13849-1 with the appropriate control system and correctly wired
    Can reach SILCL 1 conforming to EN/IEC 62061 with the appropriate control system and correctly wired
    Can reach PL = c conforming to EN/ISO 13849-1 with the appropriate control system and correctly wired
    safety reliability data
    MTTFd = 16.6 years conforming to EN/ISO 13849-1
    DC = 95.5 % conforming to EN/ISO 13849-1
    PFH = 3.12E-7 1/h conforming to EN/IEC 61508
    PFHd = 3.12E-7 1/h conforming to EN/IEC 62061
    number of inputs
    2 (terminal(s) MA, MB) for muting function
    4 (terminal(s) Z1, Z2, Z3, Z4) for sensor
    input voltage
    24 V DC (terminal(s) U+, U-) for muting function
    24 V DC for sensor
    input compatibility
    XC limit switch for muting function
    XU2M18PP340... for muting function
    XU2S18PP340... (infrared) for sensor
    XU9M18PP340... for muting function
    connections - terminals
    Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, without bezel
    Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.2...2 x 1 mm² solid cable without cable end
    Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.25...2 x 1 mm² flexible cable with cable end, without bezel
    Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.5...2 x 1.5 mm² flexible cable with cable end, with double bezel
    Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm² solid or flexible cable without cable end
    Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, with bezel
    Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.2...2 x 1.5 mm² flexible cable without cable end
    output type
    Relay 2 NO (13-14, 23-24), volt-free
    number of additional circuits
    0
    [Us] rated supply voltage
    24 V DC (- 20...20 %)
    Complementary
    sensor power supply
    24 V DC (terminal(s) U+, U-)
    supply current for sensors
    < 200 mA
    input current
    < 200 mA for muting function
    synchronisation time between inputs
    3 s (+/- 20 %) for the activation of the MA/MB muting signal
    muting maximum duration
    60 s (- 10...30 %)
    line resistance
    <= 10 Ohm for sensor power supply
    breaking capacity
    C300 : holding 180 VA AC-15 for relay output
    C300 : inrush 1800 VA AC-15 for relay output
    breaking capacity
    1.5 A / 24 V - L/R = 50 ms, DC-13 for relay output
    20 mA / 24 V for solid state output
    associated fuse rating
    4 A gG for relay output conforming to DIN VDE 0660 part 200
    4 A gG for relay output conforming to EN/IEC 60947-5-1
    6 A fast blow for relay output conforming to DIN VDE 0660 part 200
    6 A fast blow for relay output conforming to EN/IEC 60947-5-1
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    response time on input open
    <= 25 ms
    local signalling
    1 LED, function electronic internal fuse status
    1 LED, function restarting
    1 LED, function safety outputs closed
    1 LED, function safety outputs open
    1 incandescent lamp, function muting power consumption: 4...6.5 W
    output thermal current
    11 A maximum
    5.6 A per relay
    power consumption in W
    <= 15 W
    protection type
    Electronic internal fuse
    [Ui] rated insulation voltage
    300 V, degree of pollution 2 conforming to EN/IEC 60947-5-1
    300 V, degree of pollution 2 conforming to DIN VDE 0110 parts 1 and 2
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III, conforming to EN/IEC 60947-5-1
    4 kV overvoltage category III, conforming to DIN VDE 0110 parts 1 and 2
    Environment
    ambient air temperature for operation
    -10...55 °C
    ambient air temperature for storage
    -25...85 °C
    IP degree of protection
    IP20(terminals) conforming to IEC 60529
    IP40(enclosure) conforming to IEC 60529
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • French
    • Italian
    • German
    • Chinese
    Catalogue
    Date
    Size
    Add to My Documents
    Safety light curtains Preventa XUSL (Version 3.0)
    Preventa safety modules XPSCM For monitoring single-beam photo-electric sensors with a test input associated with a built-in “muting” function (Version 1.0)
    Barrières immatérielles de sécurité Preventa XUSL (Version 3.0)
    Modules de sécurité Preventa XPSCM Pour surveillance de détecteurs photoélectriques monofaisceau à entrée test associés avec fonction muting intégrée (Version 1.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for XPSCM1144P: module XPS-CM - single-beam photo-electric sensors - 24 V DC (Version 2.0)
    CAD for XPSCM1144P: module XPS-CM - single-beam photo-electric sensors - 24 V DC (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    XPSCM Type Examination (Version 1.0)
    Date 10/19/15
    Size 121.5 KB
    CCC_2007010303245539_Certificate_XPSAC_valid_20200227 (Version 1.1)
    Instruction sheet
    Date
    Size
    Add to My Documents
    XPSCM1144. Safety modules for the monitoring photo-electric sensors (Version 00)
    XPSCM... Safety modules for the monitoring photo-electric sensors (Version 01)
    End of Life Information
    Date
    Size
    Add to My Documents
    XPS... Preventa Safety Module, Product End-of-Life Instructions (Version 2.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    XPS... Preventa Safety Module, Product Environmental Profile (Version 2.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions