Characteristics
Main range of product Preventa Safety automationproduct or component type Preventa safety modulesafety module name XPSBAEsafety module application For electrical monitoring of two-hand control stationsfunction of module Monitoring two-hand control station type IIIAsafety level Can reach SILCL 1 conforming to EN/IEC 62061Can reach PL c/category 1 conforming to EN/ISO 13849-1safety reliability data MTTFd = 55 years conforming to EN/ISO 13849-1PFHd = 2.1E-6 1/h conforming to EN/IEC 62061connections - terminals Cage clamp terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm² stranded cable without cable endCage clamp terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm² solid cable without cable endCage clamp terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, with bezelCage clamp terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, without bezelCage clamp terminals, removable terminal block, clamping capacity: 2 x 0.5...2 x 1 mm² flexible cable with cable end, with double bezeloutput type Relay 1 NO, volt-freenumber of additional circuits 1 NC[Us] rated supply voltage 24 V AC/DC (- 15...10 %)Complementary synchronisation time between inputs 0.5 ssupply frequency 50/60 Hzpower consumption in W 0.8 Wpower consumption in VA 2.4 VAinput protection type Internal, electronicnumber of inputs 1 NC + NOinput current 2.5 mA NC25 mA NOinput compatibility Two-hand control conforming to EN 574[Uc] control circuit voltage 24 V DCbreaking capacity : inrush 1800 VAC300 : holding 180 VA AC-15 for relay outputbreaking capacity 2 A / 24 V - L/R = 20 ms, DC-13 for relay output[Ith] conventional free air thermal current 5 Aassociated fuse rating 6 A fast blow4 A gG for relay output conforming to EN/IEC 60947-5-1minimum output current 10 mA for relay outputminimum output voltage 17 V for relay outputresponse time on input open <= 20 ms[Ui] rated insulation voltage 300 V, degree of pollution 2 conforming to IEC 60947-5-1[Uimp] rated impulse withstand voltage 4 kV overvoltage category III, conforming to IEC 60947-5-14 kV overvoltage category III, conforming to DIN VDE 0110 part 1local signalling 2 LEDsmounting support 35 mm symmetrical DIN railproduct weight 0.1 kgEnvironment standards EN/IEC 60204-1EN/IEC 60947-5-1EN/ISO 13849-1EN 62061EN 574 type III AEN 60947-01product certifications CSATÜVULIP degree of protection IP20(terminals) conforming to EN/IEC 60529IP40(enclosure) conforming to EN/IEC 60529ambient air temperature for operation -25...55 °Cambient air temperature for storage -25...75 °COffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- French
- Polish
- Italian
- Finnish
- Chinese
- German
- Swedish
- Dutch
CatalogueSizeAdd to My DocumentsPreventa safety modules For electrical monitoring of two-hand control stations XPSBAE/BCE/BF (Version 1.0)Date 2/3/17Size 1.2 MBModules de sécurité Preventa types XPSBAE, XPSBCE, XPSBF Pour contrôle de pupitres de commande bimanuelle (Version 1.0)Date 4/18/17Size 871.2 KBCertificateSizeAdd to My DocumentsCCC Certificate XPS type ABV ATR AXE BAE BCE ECME ECPE (Version 1.2)Instruction sheetSizeAdd to My DocumentsXPS BAE Safety relays for two-hand control according to EN 574 Typ IIIA (Version 00)Date 12/14/17Size 572.3 KBDeclaration of conformitySizeAdd to My DocumentsEnd of Life InformationSizeAdd to My DocumentsXPS... Preventa Safety Module, Product End-of-Life Instructions (Version 2.0)Product Environmental ProfileSizeAdd to My DocumentsXPS... Preventa Safety Module, Product Environmental Profile (Version 2.0)REACh DeclarationSizeAdd to My DocumentsEU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Dimensions