Characteristics
Main range of product Preventa Safety automationproduct or component type Preventa safety modulesafety module name XPSAXEsafety module application For emergency stop and switch monitoringsafety level Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061safety reliability data DC > 99 % conforming to EN/ISO 13849-1PFHd = 3E-8 1/h conforming to EN/IEC 62061MTTFd = 457 years conforming to EN/ISO 13849-1connections - terminals Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm² solid cable without cable endCaptive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm² flexible cable without cable endCaptive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, without bezelCaptive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 1.5 mm² flexible cable with cable end, with bezelCaptive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.2...2 x 1 mm² solid cable without cable endCaptive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.2...2 x 1 mm² flexible cable without cable endCaptive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.25...2 x 1 mm² flexible cable with cable end, without bezelCaptive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.5...2 x 1.5 mm² flexible cable with cable end, with double bezeloutput type Relay instantaneous opening 3 NO, volt-freenumber of additional circuits 1 NC[Us] rated supply voltage 24 V AC24 V DC (- 15...10 %)Complementary synchronisation time between inputs < 0.5 ssupply frequency 50/60 Hzpower consumption in VA <= 4 VA DC[Uc] control circuit voltage 24 V DCbreaking capacity B300 : 3600 VA, AC-15 (inrush) for relay outputB300 : 360 VA, AC-15 (holding) for relay outputbreaking capacity 1.5 A at 24 V (DC-13) time constant: 50 ms for relay outputoutput thermal current 6 A for instantaneous and time delay outputsassociated fuse rating 6 A fuse type gG for instantaneous outputsminimum output current 10 mA for relay outputminimum output voltage 17 V for relay outputresponse time on input open <= 80 ms[Ui] rated insulation voltage 300 V (degree of pollution: 2) conforming to DIN VDE 0110 part 1300 V (degree of pollution: 2) conforming to IEC 60947-5-1[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60947-5-14 kV overvoltage category III conforming to DIN VDE 0110 part 1local signalling 2 LEDsmounting support 35 mm symmetrical DIN railproduct weight 0.229 kgEnvironment standards EN 1088/ISO 14119EN/IEC 60204-1EN/IEC 60947-5-1EN/ISO 13850product certifications BGCSAULIP degree of protection IP40 conforming to EN/IEC 60529IP20 conforming to EN/IEC 60529ambient air temperature for operation -25...55 °Cambient air temperature for storage -25...75 °CContractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- French
CatalogueSizeAdd to My DocumentsPreventa safety modules For Emergency stop and switch monitoring - Category 0 (Version 1.0)Date 2/3/17Size 1.5 MBModules de sécurité Preventa pour surveillance d’Arrêt d’urgence et d’interrupteurs, Catégorie 0: XPSAFL/ AR/ AK/ AXE/ AC/ AF (Version 1.0)Date 2/3/17Size 1.3 MBCertificateSizeAdd to My DocumentsCCC Certificate XPS type ABV ATR AXE BAE BCE ECME ECPE (Version 1.2)XPSAXE Functional Safety Type Examination (Version 1.0)Declaration of conformitySizeAdd to My DocumentsPreventa XPSAXE EU Declaration of Conformity (Version 1.0)End of Life InformationSizeAdd to My DocumentsXPS ABV..., XPS AC..., XPS AF..., XPS AX..., XPS BCE..., XPS BF..., XPS DMB..., XPS ECME..., XPS-VC... Safety Modules, Product End-of-Life Instructions (Version 1.0)Date 12/14/17Size 156.3 KBXPS... Preventa Safety Module, Product End-of-Life Instructions (Version 2.0)Product Environmental ProfileSizeAdd to My DocumentsXPS... Preventa Safety Module, Product Environmental Profile (Version 2.0) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Dimensions