-
Characteristics
Main range of product Preventa Safety automationproduct or component type Preventa safety modulesafety module name XPSAVsafety module application For emergency stop and switch monitoringfunction of module Monitoring of a movable guard associated with 2 switches automatic startEmergency stop monitoring 1-channel wiringEmergency stop monitoring 2-channel wiringEmergency stop button with 1 NC contact, automatic start or unmonitored startEmergency stop button with 2 NC contacts, monitored startsafety level Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061safety reliability data DC > 99 % conforming to EN/ISO 13849-1MTTFd = 75.8 years conforming to EN/ISO 13849-1PFHd = 7.95E-9 1/h conforming to EN/IEC 62061type of start Configurableconnections - terminals Captive screw clamp terminals, clamping capacity: 2 x 0.5...2 x 1.5 mm² flexible cable with cable end, with double bezelCaptive screw clamp terminals, clamping capacity: 1 x 0.14...1 x 2.5 mm² flexible cable with cable end, with double bezelCaptive screw clamp terminals, clamping capacity: 1 x 0.14...1 x 2.5 mm² solid cable with cable end, with double bezelCaptive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 1.5 mm² flexible cable with cable end, with double bezelCaptive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, with double bezelCaptive screw clamp terminals, clamping capacity: 2 x 0.14...2 x 0.75 mm² flexible cable with cable end, with double bezelCaptive screw clamp terminals, clamping capacity: 2 x 0.14...2 x 0.75 mm² solid cable with cable end, with double bezelCaptive screw clamp terminals, clamping capacity: 2 x 0.25...2 x 1 mm² flexible cable with cable end, with double bezeloutput type Relay instantaneous opening 3 NO, volt-freeRelay time delay opening 3 NO, volt-freenumber of additional circuits 3 solid state outputs[Us] rated supply voltage 24 V DC (- 20...20 %)Complementary synchronisation time between inputs Unlimited for emergency stop1.5 s for guardpower consumption in W <= 5 W DCinput protection type Internal, electronictime delay range 0...300 s[Uc] control circuit voltage 24 V DCline resistance 100 Ohm 2000 mbreaking capacity C300 : 180 VA, AC-15 (holding) for relay outputC300 : 1800 VA, AC-15 (inrush) for relay outputbreaking capacity 20 mA at 24 V1.25 A at 24 V (DC-13) time constant: 50 ms for relay outputoutput thermal current 2 A for 1 output and 4 A for the other 2 outputs for instantaneous and time delay outputs3.3 A for all 3 outputs for instantaneous and time delay outputs6 A for 1 output and 2 A for the other 2 outputs for instantaneous and time delay outputs[Ith] conventional free air thermal current 20 Aassociated fuse rating 4 A fuse type gG or gL for instantaneous and time delay outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 2006 A fuse type fast blow conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200minimum output current 10 mA for relay outputminimum output voltage 17 V for relay outputresponse time on input open <= 30 ms[Ui] rated insulation voltage 300 V (degree of pollution: 2) conforming to DIN VDE 0110 part 1300 V (degree of pollution: 2) conforming to IEC 60947-5-1[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60947-5-14 kV overvoltage category III conforming to DIN VDE 0110 part 1local signalling 11 LEDsmounting support 35 mm symmetrical DIN railproduct weight 0.32 kgEnvironment standards EN 1088/ISO 14119EN/IEC 60204-1EN/IEC 60947-5-1EN/ISO 13850product certifications CSATÜVULIP degree of protection IP20 (terminals) conforming to EN/IEC 60529IP40 (enclosure) conforming to EN/IEC 60529ambient air temperature for operation -10...55 °Cambient air temperature for storage -25...85 °CContractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- Portuguese
- Danish
- French
- Finnish
- Italian
- German
- Swedish
- Norwegian
- Dutch
CatalogueSizeAdd to My DocumentsPreventa safety modules For Emergency stop and switch monitoring - Category 1 XPSABV/ATR/AV/ATE (Version 1.0)Date 2/3/17Size 1.7 MBModules de sécurité Preventa XPSABV/ATR/AV/ATE pour surveillance d’Arrêt d’urgence et d'interrupteurs, Catégorie 1 (Version 1.0)Date 2/20/17Size 1.2 MBCertificateSizeAdd to My DocumentsCCC Certificate XPS type AC AF AFL AK (Version 1.0)XPSAC AF AFL AK AR ATE AV Type Examination (Version 2.0)Instruction sheetSizeAdd to My DocumentsXPSAV... Safety module for emergency stop and switch monitoring (Version 02)XPSAV... Safety module for emergency stop and switch monitoring (Version 02)XPSAV... Safety module for emergency stop and switch monitoring (Version 00)XPSAV... Safety module for emergency stop and switch monitoring (Version 02)Declaration of conformitySizeAdd to My DocumentsPreventa DoC XPSAF XPSAFL XPSAK XPSAR XPSATE XPSAV (Version 1.0)End of Life InformationSizeAdd to My DocumentsXPS ABV..., XPS AC..., XPS AF..., XPS AX..., XPS BCE..., XPS BF..., XPS DMB..., XPS ECME..., XPS-VC... Safety Modules, Product End-of-Life Instructions (Version 1.0)Date 12/14/17Size 156.3 KBXPS... Preventa Safety Module, Product End-of-Life Instructions (Version 2.0)Product Environmental ProfileSizeAdd to My DocumentsXPS... Preventa Safety Module, Product Environmental Profile (Version 2.0) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Dimensions