  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety module
    safety module name
    XPSABV
    safety module application
    For emergency stop and switch monitoring
    safety level
    Can reach PL d/category 3 conforming to EN/ISO 13849-1 time delay safety outputs
    Can reach PL e/category 4 conforming to EN/ISO 13849-1 instantaneous safety outputs
    Can reach SILCL 3 conforming to EN/IEC 62061 instantaneous safety outputs
    Can reach SILCL 2 conforming to EN/IEC 62061 time delay safety outputs
    safety reliability data
    MTTFd = 53 years conforming to EN/ISO 13849-1 instantaneous safety outputs
    MTTFd = 53 years conforming to EN/ISO 13849-1 time delay safety outputs
    DC > 99 % conforming to EN/ISO 13849-1 instantaneous safety outputs
    DC = 60...90 % conforming to EN/ISO 13849-1 time delay safety outputs
    PFHd = 3E-8 1/h conforming to EN/IEC 62061 instantaneous safety outputs
    PFHd = 2E-7 1/h conforming to EN/IEC 62061 time delay safety outputs
    connections - terminals
    Spring terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm² solid cable without cable end
    Spring terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm² flexible cable without cable end
    Spring terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, without bezel
    Spring terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, with bezel
    Spring terminals, removable terminal block, clamping capacity: 2 x 0.5...2 x 1 mm² flexible cable with cable end, with double bezel
    Spring terminals, removable terminal block
    output type
    Relay instantaneous opening 2 NO, volt-free
    Relay time delay opening 1 NO, volt-free
    number of additional circuits
    0
    [Us] rated supply voltage
    24 V DC (- 15...10 %)
    Complementary
    synchronisation time between inputs
    < 0.5 s
    power consumption in W
    <= 3 W
    input protection type
    Internal, electronic
    time delay range
    1.5...30 s
    0.15...3 s
    [Uc] control circuit voltage
    24 V DC
    breaking capacity
    B300 : 3600 VA, AC-15 (inrush)
    B300 : 360 VA, AC-15 (holding)
    breaking capacity
    1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
    output thermal current
    6 A for instantaneous and time delay outputs
    [Ith] conventional free air thermal current
    12 A
    associated fuse rating
    6 A fuse type gG for instantaneous and time delay outputs
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    response time on input open
    <= 200 ms
    [Ui] rated insulation voltage
    300 V (degree of pollution: 2) conforming to DIN VDE 0110 part 1
    300 V (degree of pollution: 2) conforming to IEC 60947-5-1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to IEC 60947-5-1
    4 kV overvoltage category III conforming to DIN VDE 0110 part 1
    local signalling
    3 LEDs
    mounting support
    35 mm symmetrical DIN rail
    product weight
    0.275 kg
    Environment
    standards
    EN 1088/ISO 14119
    EN/IEC 60947-5-1
    EN/ISO 13850
    EN/IEC 60204-1
    product certifications
    BG
    CSA
    UL
    IP degree of protection
    IP40 conforming to EN/IEC 60529
    IP20 conforming to EN/IEC 60529
    ambient air temperature for operation
    -25...55 °C
    ambient air temperature for storage
    -25...75 °C
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    • Chinese
    Catalogue
    Date
    Size
    Add to My Documents
    Safety modules Preventa XPSABV For Emergency stop and switch monitoring - Category 1 (Version 2.0)
    Modules de sécurité Preventa XPSABV Pour surveillance d’Arrêt d’urgence et d’interrupteurs (Version 2.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD for XPSABV1133C: module XPSABV - stop and switch monitoring - 24 V AC/DC (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    CCC_2013010303592422_Certificate_XPSAXE_valid_20221220 (Version 1.3)
    XPSABV Type Examination (Version 1.0)
    Date 12/6/17
    Size 613.6 KB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Preventa DoC XPSABV (Version 1.0)
    Date 6/12/18
    Size 530.8 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    XPS... Preventa Safety Module, Product End-of-Life Instructions (Version 2.0)
    XPS ABV..., XPS AC..., XPS AF..., XPS AX..., XPS BCE..., XPS BF..., XPS DMB..., XPS ECME..., XPS-VC... Safety Modules, Product End-of-Life Instructions (Version 1.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    XPS... Preventa Safety Module, Product Environmental Profile (Version 2.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



Compare products: /