Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Harmony XAC
Schneider Electric XENC1121 Image

XENC1121

Schneider Electric XENC1121 Image
XENC1121

PENDANT STATION CONTACT 240VAC 3A XAC

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Harmony XAC
    product or component type
    Contact block
    component name
    XENC
    electrical circuit type
    Control circuit
    contact block application
    Single speed
    contact block type
    Single
    type of operator
    Spring return
    product compatibility
    XACB
    XACM
    mechanical interlocking
    Without mechanical interlock
    contacts type and composition
    1 NC
    mounting of block
    Front mounting
    contact operation
    Slow-break
    Complementary
    connections - terminals
    Screw clamp terminals, connection capacity: 1 x 2.5 mm² with or without cable end
    Screw clamp terminals, connection capacity: 2 x 1.5 mm² with or without cable end
    mechanical durability
    1000000 cycles
    contact code designation
    A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
    Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
    [Ithe] conventional enclosed thermal current
    10 A
    [Ui] rated insulation voltage
    500 V (degree of pollution: 3) conforming to IEC 60947-1
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-1
    resistance across terminals
    <= 25 MOhm
    short-circuit protection
    10 A fuse protection by cartridge fuse type gG
    rated operational power in W
    42 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
    45 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
    60 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
    rated operational power in VA
    140 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load)
    385 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load)
    455 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)
    525 VA AC-15 for 1000000 cycles, operating rate = 60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load)
    terminals description ISO n°1
    (11-12)NC
    terminal identifier
    (11-12)NC
    (13-14)NO
    product weight
    0.02 kg
    Environment
    standards
    EN 60947-5-1
    IEC 60947-5-1
    CSA C22.2 No 14
    ambient air temperature for operation
    -25...70 °C
    ambient air temperature for storage
    -40...70 °C
    vibration resistance
    15 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
    shock resistance
    100 gn conforming to IEC 60068-2-27
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    Catalogue
    Date
    Size
    Add to My Documents
    Harmony XAC pendant control stations catalog (Version 1.0)
    Harmony XAC pendant control stations catalog (Version 1.0)
    Pendant Stations (Version 1.1)
    Date 7/31/13
    Size 2.2 MB
    Certificate
    Date
    Size
    Add to My Documents
    XACB (Control circuit) Pendant control station (Version 1.0)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    XACB, XACF, XACM Pendant control station (Version 1.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /