Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Harmony XAC
Schneider Electric XACB6911 Image

XACB6911

Schneider Electric XACB6911 Image
XACB6911

pendant control station XAC-B - 6 pushbuttons 1 Emergency stop

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

XACB6911 is replaced by:
Product
Qty
XACB6913
Qty
1
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4
  • Reason for Substitution: End of life
  • Substitution date: 24 January 2014
1
  • Main
    range of product
    Harmony XAC
    product or component type
    Pendant control station
    device short name
    XACB
    Complementary
    control station type
    Double insulated
    enclosure material
    Glass reinforced polyester
    electrical circuit type
    Power circuit
    enclosure type
    Complete ready for use
    control station application
    Control of single speed hoist motor
    control station composition
    6 push-buttons + 1 emergency stop
    control button type
    Stop push-button Ø 40 mm 3 NC latching
    First push-button 2-pole raise, slow
    Second push-button 2-pole lower, slow
    Fourth push-button 2-pole left, slow
    Third push-button 2-pole right, slow
    Fifth push-button 2-pole forward slow
    Sixth push-button 2-pole reverse, slow
    product compatibility
    XESD1191 for reversing operation
    XACS3991 for emergency stop
    mechanical interlocking
    With mechanical interlocking between pairs
    control station colour
    Yellow
    connections - terminals
    Screw clamp terminals, 1 x 2.5 mm² with or without cable end
    Screw clamp terminals, 2 x 1.5 mm² with or without cable end
    standards
    CSA C22.2 No 14
    EN/IEC 60947-5-1
    EN/IEC 60204-32
    product certifications
    CSA type 4
    protective treatment
    TH
    ambient air temperature for operation
    -25…70 °C
    ambient air temperature for storage
    -40…70 °C
    vibration resistance
    15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
    shock resistance
    100 gn conforming to IEC 60068-2-27
    overvoltage category
    Class II conforming to IEC 61140
    IP degree of protection
    IP65 conforming to IEC 60529
    mechanical durability
    1000000 cycles
    cable entry
    Rubber sleeve with stepped entry 10…22 mm
    [Ithe] conventional enclosed thermal current
    12 A
    [Ui] rated insulation voltage
    Emergency stop contact: 400 V (pollution degree 3) conforming to IEC 60947-1
    600 V conforming to CSA
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-1
    contact operation
    Snap action
    operating force
    17 N push-button
    40 N emergency stop
    short-circuit protection
    10 A fuse protection by cartridge fuse type aM
    rated power in hp
    2 hp at 240 V, CSA certified
    3 hp at 600 V, CSA certified
    5 hp at 400 V, CSA certified
    rated operational power in W
    2200 W AC-3 at 240 V conforming to IEC 60947-3 appendix A
    2200 W AC-3 at 400 V conforming to IEC 60947-3 appendix A
    2200 W AC-4 at 240 V conforming to IEC 60947-3 appendix A
    2200 W AC-4 at 400 V conforming to IEC 60947-3 appendix A
    electrical durability
    300000 cycles AC-3, 2200 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    300000 cycles AC-3, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    300000 cycles AC-4, 2200 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    300000 cycles AC-4, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    500000 cycles AC-3, 1500 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    500000 cycles AC-4, 1500 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    800000 cycles AC-3, 1500 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    800000 cycles AC-4, 1500 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
    terminals description ISO n°1
    (23-24)NO
    (43-44)NO
    (13-14)NO
    (33-34)NO
    terminals description ISO n°2
    (11-12)NC
    (31-32)NC
    (21-22)NC
    terminal identifier
    (11-12)NC
    (13-14)NO
    net weight
    1.5 kg
    Contractual warranty
    Warranty
    18 months
  • Documents

    Language
    • English
    • Kazakh
    • Russian
    • French
    Certificate
    Date
    Size
    Add to My Documents
    XAC, XAL, XAPS, XAW Control Stations (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    XACB... / XACM... Pendant control station, mounting with components (Version 08)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /