Range: Harmony XAC

Complete pendant control stations

XACB3191

Schneider Electric XACB3191 Image
Range: Harmony XAC

Complete pendant control stations

XACB3191

pendant control station XAC-B - 2 pushbuttons 1 Emergency stop

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Harmony XAC
    product or component type
    Pendant control station
    device short name
    XACB
    Complementary
    control station type
    Double insulated
    enclosure material
    Glass reinforced polyester
    electrical circuit type
    Power circuit
    enclosure type
    Complete ready for use
    control station application
    Control of single speed hoist motor
    control station composition
    2 push-buttons + 1 emergency stop
    control button type
    Stop push-button Ø 40 mm 3 NC latching
    First push-button 2-pole raise, slow
    Second push-button 2-pole lower, slow
    product compatibility
    XESD1191 for reversing operation
    XACS499 for emergency stop
    mechanical interlocking
    With mechanical interlocking
    control station colour
    Yellow
    connections - terminals
    Screw clamp terminals 1 x 2.5 mm² with or without cable end
    Screw clamp terminals 2 x 1.5 mm² with or without cable end
    standards
    EN/IEC 60204-32
    CSA C22.2 No 14
    EN/IEC 60947-5-1
    product certifications
    CSA type 4
    protective treatment
    TH
    ambient air temperature for operation
    -25...70 °C
    ambient air temperature for storage
    -40...70 °C
    vibration resistance
    15 gn 10...500 Hz IEC 60068-2-6
    shock resistance
    100 gn IEC 60068-2-27
    overvoltage category
    Class II IEC 61140
    IP degree of protection
    IP65 IEC 60529
    mechanical durability
    1000000 cycles
    cable entry
    Rubber sleeve with stepped entry 10...22 mm
    [Ithe] conventional enclosed thermal current
    12 A
    [Ui] rated insulation voltage
    400 V 3 IEC 60947-1 emergency stop contact
    600 V CSA
    [Uimp] rated impulse withstand voltage
    6 kV IEC 60947-1
    contact operation
    Snap action
    operating force
    17 N push-button
    40 N emergency stop
    short-circuit protection
    <= 10 A fuse protection cartridge aM
    rated power in hp
    2 hp CSA 240 V
    3 hp CSA 600 V
    5 hp CSA 400 V
    rated operational power in W
    2200 W AC-3 240 V IEC 60947-3 appendix A
    2200 W AC-3 400 V IEC 60947-3 appendix A
    2200 W AC-4 240 V IEC 60947-3 appendix A
    2200 W AC-4 400 V IEC 60947-3 appendix A
    electrical durability
    300000 cycles AC-3 2200 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
    300000 cycles AC-3 2200 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
    300000 cycles AC-4 2200 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
    300000 cycles AC-4 2200 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
    500000 cycles AC-3 1500 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
    500000 cycles AC-4 1500 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
    800000 cycles AC-3 1500 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
    800000 cycles AC-4 1500 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
    terminals description ISO n°1
    (43-44)NO
    (13-14)NO
    (33-34)NO
    (23-24)NO
    terminals description ISO n°2
    (31-32)NC
    (21-22)NC
    (11-12)NC
    terminal identifier
    (13-14)NO
    (11-12)NC
    product weight
    0.94 kg
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Kazakh
    • Russian
    • French
    Certificate
    Date
    Size
    Add to My Documents
    Date 9/24/17
    Size 1.8 MB
    Date 9/18/17
    Size 897 KB
    Date 9/18/17
    Size 1.8 MB
    Instruction sheet
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.