Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    device short name
    AIC
    network number of phases
    3 phases
    [Us] rated supply voltage
    380...480 V (+/- 10 %)
    network frequency
    50/60 Hz
    rated power in W
    145 kW
    range compatibility
    Altivar 61
    Altivar 71
    product specific application
    Component of the Active Front End
    Energy regeneration
    Low harmonics
    product compatibility
    ATV61HC13N4D 380...440 V AC with one variable speed drive
    ATV71HC11N4D 380...440 V AC with one variable speed drive
    ATV61HC13N4D 480 V AC with one variable speed drive
    ATV71HC11N4D 480 V AC with one variable speed drive
    ATV61H075N4...C40N4D DC with several variable speed drive on a common DC bus
    ATV71H075N4...C31N4D DC with several variable speed drive on a common DC bus
    assembly style
    Built-in unit
    type of cooling
    Forced convection
    Complementary
    line current
    160 A at 480 V
    212 A at 400 V
    input power
    146 kW at 400 V
    166 kW at 480 V
    continuous output current
    220 A at 400 V
    203 A at 480 V
    output voltage
    650 V DC - supply:380...400 V AC
    720 V DC - supply:440 V AC
    770 V DC - supply:480 V AC
    thermal losses
    2660 W
    max current
    1.20 x nominal current for 60 s
    1.35 x nominal current for 2 s
    voltage drop at rated load
    30 % at 380...400 V, <= 60 s
    40 % at 440 V, <= 60 s
    40 % at 480 V, <= 60 s
    communication port protocol
    Modbus
    CANopen
    connector type
    1 RJ45 for Modbus
    Male SUB-D 9 on RJ45 for CANopen
    option card
    Communication bridge
    operating position
    Vertical +/- 10 degree
    height
    782 mm
    width
    350 mm
    depth
    377 mm
    product weight
    74 kg
    Environment
    environmental characteristic
    3K3 conforming to EN/IEC 60721-3-3
    3C2 conforming to EN 60721-3-3
    3S2 conforming to EN 60721-3-3
    relative humidity
    0...95 %
    ambient air temperature for operation
    45...60 °C with current derating of 2 % per °C
    -10...45 °C
    ambient air temperature for storage
    -25...70 °C
    operating altitude
    <= 1000 m without derating
    1000...3000 m with current derating 1 % per 100 m
    pollution degree
    2 conforming to EN 61800-5-1
    vibration resistance
    0.6 gn (f = 10...200 Hz) conforming to EN/IEC 60068-2-6
    1.5 mm (f = 3...10 Hz) conforming to EN/IEC 60068-2-6
    shock resistance
    7 gn for 11 ms conforming to EN/IEC 60721-3-3
    air flow surface
    700 cm²
    volume of cooling air
    600 m3/h for power circuit
    145 m3/h for control circuit
    IP degree of protection
    IP00
    standards
    EN/IEC 61800-5-1
    product certifications
    CE
    UL (pending)
    CSA (pending)
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  1601  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Need no specific recycling operations
    Contractual warranty
    Warranty period
    18 months
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /