Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Actassi
Schneider Electric VDICD416118 Image

VDICD416118

Schneider Electric VDICD416118 Image
VDICD416118

Actassi Cable LAN U/UTP 4P Cat6 Euroclass D 250MHz LSZH 305m

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    Actassi
    product or component type
    Network cable
    cable packaging
    Box of 305 m
    colour tint
    White
    cable shielding type
    U/UTP
    Complementary
    localisation on device
    Jacket : LSZH (low smoke zero halogen)
    Conductor : solid bare copper
    Wire insulation : PE (polyethylene)
    type of cable
    4 twisted-pairs cable
    communication network category
    6
    communication port protocol
    PoE 15W (Power over Ethernet)
    PoE+ 30W (Power over Ethernet Plus)
    VoIP (Voice IP)
    communication network type
    10/100/1000BASE-T
    return loss
    Guaranteed: >= 20 dB Typical: 22 dB @1 MHz
    Guaranteed: >= 23 dB Typical: 25 dB @4 MHz
    Guaranteed: >= 25 dB Typical: 27 dB @10 MHz
    Guaranteed: >= 25 dB Typical: 27 dB @16 MHz
    Guaranteed: >= 25 dB Typical: 27 dB @20 MHz
    Guaranteed: >= 23.6 dB Typical: 26 dB @31.2 MHz
    Guaranteed: >= 21.5 dB Typical: 24 dB @62.5 MHz
    Guaranteed: >= 20.1 dB Typical: 23 dB @100 MHz
    Guaranteed: >= 19.5 dB Typical: 22 dB @125 MHz
    Guaranteed: >= 18.8 dB Typical: 21 dB @155.5 MHz
    Guaranteed: >= 18.4 dB Typical: 21 dB @175 MHz
    Guaranteed: >= 18 dB Typical: 20 dB @200 MHz
    Guaranteed: >= 17.3 dB Typical: 19 dB @250 MHz
    attenuation
    2.1 dB at 1 MHz 1.9 dB
    3.8 dB at 4 MHz 3.8 dB
    6 dB at 10 MHz 6 dB
    7.6 dB at 16 MHz 7.6 dB
    8.5 dB at 20 MHz 8.5 dB
    10.7 dB at 31.2 MHz 10.7 dB
    15.5 dB at 62.5 MHz 15.1 dB
    19.9 dB at 100 MHz 19.1 dB
    22.5 dB at 125 MHz 21.3 dB
    25.4 dB at 155.5 MHz 23.8 dB
    27.1 dB at 175 MHz 25.3 dB
    29.2 dB at 200 MHz 27 dB
    33 dB at 250 MHz 32 dB
    power sum near-end crosstalk [PS NEXT]
    Guaranteed: 72 dB Typical: 75 dB at 1 MHz
    Guaranteed: 63 dB Typical: 66 dB at 4 MHz
    Guaranteed: 57 dB Typical: 60 dB at 10 MHz
    Guaranteed: 54 dB Typical: 57 dB at 16 MHz
    Guaranteed: 53 dB Typical: 56 dB at 20 MHz
    Guaranteed: 50 dB Typical: 53 dB at 31.2 MHz
    Guaranteed: 45 dB Typical: 48 dB at 62.5 MHz
    Guaranteed: 42 dB Typical: 45 dB at 100 MHz
    Guaranteed: 41 dB Typical: 44 dB at 125 MHz
    Guaranteed: 40 dB Typical: 42 dB at 155.5 MHz
    Guaranteed: 39 dB Typical: 41 dB at 175 MHz
    Guaranteed: 38 dB Typical: 41 dB at 200 MHz
    Guaranteed: 36 dB Typical: 39 dB at 250 MHz
    power sum alien near-end crosstalk [PS ANEXT]
    72 dB at 1 MHz
    63 dB at 4 MHz
    57 dB at 10 MHz
    54 dB at 16 MHz
    53 dB at 20 MHz
    50 dB at 31.2 MHz
    45 dB at 62.5 MHz
    42 dB at 100 MHz
    41 dB at 125 MHz
    40 dB at 155.5 MHz
    39 dB at 175 MHz
    38 dB at 200 MHz
    36 dB at 250 MHz
    attenuation to Crosstalk Ratio Far-end [ACR-F]
    Guaranteed: 72 dB Typical: 76.1 dB @1 MHz
    Guaranteed: 61.2 dB Typical: 65.2 dB @4 MHz
    Guaranteed: 53 dB Typical: 57 dB @10 MHz
    Guaranteed: 48.4 dB Typical: 52.3 dB @16 MHz
    Guaranteed: 46.5 dB Typical: 50 dB @20 MHz
    Guaranteed: 41.3 dB Typical: 45 dB @31.2 MHz
    Guaranteed: 31.5 dB Typical: 36 dB @62.5 MHz
    Guaranteed: 24.1 dB Typical: 28.9 dB @100 MHz
    Guaranteed: 20.5 dB Typical: 25.2 dB @125 MHz
    Guaranteed: 16.6 dB Typical: 21.3 dB @155.5 MHz
    Guaranteed: 13.9 dB Typical: 19.1 dB @175 MHz
    Guaranteed: 10.8 dB Typical: 16.5 dB @200 MHz
    Guaranteed: 5 dB Typical: 10 dB @250 MHz
    power sum attenuation crosstalk ratio far-end [PS ACR-F]
    70 dB 1 MHz
    59.2 dB 4 MHz
    51 dB 10 MHz
    46.4 dB 16 MHz
    44.5 dB 20 MHz
    39.3 dB 31.2 MHz
    29.5 dB 62.5 MHz
    22.1 dB 100 MHz
    18.5 dB 125 MHz
    14.6 dB 155.5 MHz
    11.9 dB 175 MHz
    8.8 dB 200 MHz
    2 dB 250 MHz
    equal level far end crosstalk [ELFEXT]
    44 dB
    38 dB
    24 dB
    56 dB at 4 MHz
    48 dB at 10 MHz
    56 dB
    42 dB at 20 MHz
    48 dB
    28 dB at 100 MHz
    22 dB at 200 MHz
    42 dB
    20 dB at 250 MHz
    28 dB
    22 dB
    20 dB
    23 dB
    32 dB
    68 dB at 1 MHz
    68 dB
    44 dB at 16 MHz
    38 dB at 31.2 MHz
    32 dB at 62.5 MHz
    26 dB at 125 MHz
    24 dB at 155.5 MHz
    23 dB at 175 MHz
    26 dB
    power sum equal level far end crosstalk [PSELFEXT]
    53 dB at 4 MHz
    45 dB at 10 MHz
    39 dB at 20 MHz
    25 dB at 100 MHz
    19 dB at 200 MHz
    17 dB at 250 MHz
    65 dB at 1 MHz
    41 dB at 16 MHz
    35 dB at 31.2 MHz
    29 dB at 62.5 MHz
    23 dB at 125 MHz
    21 dB at 155.5 MHz
    20 dB at 175 MHz
    input impedance
    100 Ohm at 1...400 MHz
    resistance unbalance
    <= 2 %
    bending radius
    Minimum bending radius after installation : 4 x overall diameter
    Minimum bending radius during installation : 8 x overall diameter
    delay skew
    20 ns 1...400 MHz
    euroclass level
    D
    nominal velocity propagation
    68 %
    AWG gauge
    AWG 24
    cable outer diameter
    5.3 mm
    cable weight
    36 kg
    targeted region
    Europe
    Environment
    ambient air temperature for installation
    0...50 °C
    ambient air temperature for storage
    -20...60 °C
    temperature resistance
    60 °C
    ambient air temperature for operation
    -20...60 °C
    directives
    2006/95/EC - low voltage directive
    2011/65/EU - RoHS directive
    305/2011/EU - construction product regulation
    standards
    EIA/TIA-568-C.2
    Acidity of combustion gases : IEC 60754-2
    Smoke generation : IEC 61034
    Performance : EN 50173-1
    Flame propagation characteristics : IEC 60332-1
    Performance : EN 50288-6-1
    Performance : IEC 61156-5 ed. 2.1
    Performance : ISO/IEC 11801 ed. 2.1
    Performance : IEEE 802.3
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  1723  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Product end of life instructions
    Need no specific recycling operations
  • Documents and Downloads

    Language
    • English
    Certificate
    Date
    Size
    Add to My Documents
    English (Version 1.0)
    Date 3/29/19
    Size 67.7 KB
    declaration of performance(DoP) (Version 1.0)
    Date 7/7/17
    Size 511.3 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 9/15/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Copper LAN Cable CAT.6 UUTP 4P LSZH - Lexcom Infraplus CL-C6 (Version 1.1)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 9/15/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /