Preventa safety module - 24 V DC - standard format - < 5 W

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon Premium Automation platform
    product or component type
    Preventa safety module
    Complementary
    [Us] rated supply voltage
    24 V DC
    supply voltage limits
    19.2...30 V
    activation threshold
    < 20 V
    short-circuit protection
    1 A gG external conforming to IEC 947-5-1 on power supply
    4 A gG external conforming to IEC 947-5-1 on safety relay outputs
    isolation voltage
    4000 V III 2
    discrete input number
    1 double or single contact selection input conforming to IEC 1131 Type 1
    1 feedback loop input conforming to IEC 1131 Type 1
    1 reset PB input conforming to IEC 1131 Type 1
    1 reset PB monitoring input conforming to IEC 1131 Type 1
    12 emergency stop or limit switch discrete inputs conforming to IEC 1131 Type 1
    discrete input logic
    Positive
    inrush current
    <= 0.5 A
    isolation between input and earth
    500 Vrms 50/60 Hz for 60 s
    power dissipation in W
    < 5 W
    safety outputs
    2 NO safety relay AGCDO gold plated volt free output
    [Ue] rated operational voltage
    17...127 V DC relay output
    19...250 V AC relay output
    rated power in VA
    120 VA 48 V AC-15 inductive
    280 VA 110 V AC-15 inductive
    550 VA 220 V AC-15 inductive
    60 VA 24 V AC-15 inductive
    rated power in W
    60 W 24 V DC-13 inductive 100 ms
    [Ithe] conventional enclosed thermal current
    <= 2.5 A
    minimum output current
    >= 30 mA
    response time on output
    < 12 ms
    isolation between output and earth
    300 V conforming to DIN VDE 0110 part 2
    1500 Vrms 50/60 Hz for 60 s
    safety acquisition
    Monitor external power supply of the module
    Read enable inputs
    Read feedback loop
    Read the safety outputs control
    Read status of the 24 inputs
    local signalling
    28 LEDs diagnostic of safety system
    electrical connection
    1 connector removable screw terminal block 6 pins for connecting the safety output
    1 connector SUB-D 44 pins for connecting the safety system input
    cable cross section
    1.5 mm² with cable end safety output circuit
    0.2...2.5 mm² without cable end safety output circuit
    current consumption
    < 150 mA 5 V DC
    <= 200 mA 24 V DC
    module format
    Standard
    product weight
    0.43 kg
    Environment
    ambient air temperature for operation
    0...40 °C without fan
    0...60 °C with fan module
    ambient air temperature for storage
    -25...70 °C
    IP degree of protection
    IP20 conforming to IEC 60529
    standards
    CSA C22.2 specific requirements (PLC)
    EN 954 machine safety parts of control systems
    EN/IEC 60204-1 machine electrical equipment
    EN/IEC 61131-2 specific requirements (PLC)
    EN/ISO 12100 machine electrical equipment
    ISO 13850 emergency stop equipment
    UL 508 specific requirements (PLC)
    ISO 13849-1 category 4 machine safety parts of control systems
    IEC 61508 SIL 3 machine safety parts of control systems
    product certifications
    BG
    CSA
    UL
    protective treatment
    Conformal coating Humiseal 1A33
    Offer Sustainability
    RoHS (date code: YYWW)
    Compliant  - since  0927  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language