View all
Logic controller - Modicon M258
Logic controller - Modicon M258 - TM258LF42DT4LS0
Logic Controllers
View all
Logic controller - Modicon M258
Logic controller - Modicon M258
-
TM258LF42DT4LS0
Logic Controllers
compact base M258 - 42 + 4 I/O - 24 V DC - CANopen - solution
Show more characteristics >-
Characteristics
Main range of product Modicon M258product or component type Logic controllerproduct specific application For solutionssoftware function Applicatives functions blocksdiscrete I/O number 42analogue input number 4discrete output number 12 for output4 for fast outputComplementary discrete input number 10 for fast input12 for input4 for regular inputdiscrete input logic Sink for fast inputSink for regular inputSource for inputdiscrete input voltage 24 Vdiscrete input voltage type DCanalogue input type Current 0...20 mACurrent 4...20 mAVoltage +/- 10 Vanalogue input resolution 12 bitsvoltage state 1 guaranteed >= 15 V for fast input>= 15 V for fast output>= 15 V for regular inputvoltage state 0 guaranteed <= 5 V for fast input<= 5 V for fast output<= 5 V for regular inputdiscrete input current 4 mA for fast input4 mA for regular inputinput impedance 6 kOhm for fast input6 kOhm for regular inputconfigurable filtering time 0 ms for fast input/regular input and fast output1.5 ms for fast input/regular input and fast output12 ms for fast input/regular input and fast output4 ms for fast input/regular input and fast outputanti bounce filtering 2 µs...4 ms (configurable) fast input/regular input and fast outputcable distance between devices 30 m for fast input30 m for fast output30 m for regular inputisolation between channels and internal logic 500 Vrms ACisolation between channels Nonediscrete output logic Sourcediscrete output voltage 24 V DCoutput voltage limits 19.2...28.8 Vdiscrete output current 4 mA for fast output[Us] rated supply voltage 24 V DC for embedded expert modules power24 V DC for I/O power segment24 V DC for main supplysupply voltage limits 20.4...28.8 V[In] rated current 0.04 A for embedded expert modules power0.31 A for main supply10 A for I/O power segmentpeak current <= 100 kA during <= 70 s main supply<= 25 kA during <= 500 s I/O power segment<= 50 kA during <= 150 s embedded expert modules power1.2 A during > 70 s main supplypower consumption in W <= 14.14 Wexecution time per instruction 22 ns : Booleanmemory description Flash 128 MBInternal RAM 64 MBrealtime clock With user calibration realtime clock, drift: <= 6 s/monthWithout any user calibration realtime clock, drift: < 30 s/month at 25 °Cdata backed up Variables of type retain and retain persistent CR2477M Renata, 1.5 years autonomyintegrated connection type 1 CANopen male SUB-D 9, CANopen master1 isolated serial link female RJ45, Ethernet Modbus TCP/IP slave (10BASE-T/100BASE-TX)2 free slots PCI1 isolated serial link female RJ45, Modbus master/slave RTU/ASCII or character mode ASCII (RS232/RS485), 300...115200 bps1 isolated serial link mini B USB, 480 Mbit/s1 isolated serial link USB type A, 480 Mbit/stransmission rate 125 kbit/s for bus length of 500 m, CANopen250 kbit/s for bus length of 250 m, CANopen50 kbit/s for bus length of 1000 m, CANopen500 kbit/s for bus length of 100 m, CANopen10 kbit/s for bus length of 5000 m, CANopen1000 kbit/s for bus length of 4 m, CANopen20 kbit/s for bus length of 2500 m, CANopen800 kbit/s for bus length of 25 m, CANopencounting input number 8 counting input(s) 200 kHzlocal signalling 1 LED per channel for I/O state1 LED for CAN0 STS1 LED for MBS COM1 LED green/red for APP01 LED green/red for APP11 LED green/red for Eth NS (Ethernet network status)1 LED green/red for Eth ST (Ethernet status)1 LED green/red for RUN/MS (module status)1 LED green/red for USB host1 LED green/yellow for Eth LA (Ethernet activity)1 LED red for BATT (battery status)marking CEmounting support Symmetrical DIN railwidth 237.5 mmheight 99 mmdepth 85 mmproduct weight 0.77 kgEnvironment standards CSA C22.2 No 142IEC 61131-2UL 508CSA C22.2 No 213product certifications CSAC-TickcULusGOST-Rambient air temperature for operation 0...55 °C without derating factor horizontal installation0...60 °C with derating factor horizontal installation0...50 °C vertical installationambient air temperature for storage -25...70 °Crelative humidity 5...95 % without condensationIP degree of protection IP20 conforming to IEC 61131-2pollution degree 2 conforming to IEC 60664operating altitude 0...2000 mstorage altitude 0...3000 mvibration resistance 1 gn 8.4...150 Hz DIN rail3.5 mm 5...8.4 Hz DIN railshock resistance 15 gn for 11 msresistance to electrostatic discharge 4 kV on contact conforming to EN/IEC 61000-4-28 kV in air conforming to EN/IEC 61000-4-2resistance to electromagnetic fields 1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-310 V/m 80...2000 MHz conforming to EN/IEC 61000-4-3resistance to fast transients 1 kV I/O conforming to EN/IEC 61000-4-41 kV shielded cable conforming to EN/IEC 61000-4-42 kV power lines conforming to EN/IEC 61000-4-4surge withstand 0.5 kV differential mode conforming to EN/IEC 61000-4-51 kV common mode conforming to EN/IEC 61000-4-5disturbance radiated/conducted CISPR 11Offer Sustainability RoHS (date code: YYWW) REACh Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- French
- Italian
- Chinese
- German
User guideSizeAdd to My DocumentsSoMachine - Compatibilité et migration, Guide utilisateur (Version 06)Modicon M258 Logic Controller, Programming Guide (Version 09)SoMachine Compatibility and Migration, User Guide (Version 06)SoMachine - Kompatibilität und Migration, Benutzerhandbuch (Version 06)Modicon M258 Logic Controller, Guía de programación (Version 09)Modicon M258 Logic Controller, Programmierhandbuch (Version 09)Modicon M258 Logic Controller, Guide de programmation (Version 09)SoMachine - Compatibilidad y migración, Guía del usuario (Version 06)SoMachine 兼容性和迁移 用户指南 (Version 06)Modicon M258 Logic Controller, 编程指南 (Version 09)Modicon M258 Logic Controller, Guida alla programmazione (Version 09)Compatibilità e migrazione di SoMachine, Guida utente (Version 06)CertificateSizeAdd to My DocumentsRCM_SupplierDeclarationOfConformity_M258_TM5_TM7 (Version 1.0)Declaration of conformitySizeAdd to My DocumentsLexium Declaration of Incorporation MAX - Series (Version 1.1)End of Life InformationSizeAdd to My DocumentsTM258L... M258 Controller, Product End-of-Life Instructions (Version 1.0)M258 Logic Controller, Product End-of-Life Instructions (Version 2.0)EU RoHS DeclarationSizeAdd to My DocumentsMarine certificateSizeAdd to My DocumentsLR Marine Certificate of Modicon TM258 TM5 LMC058 PLCs (Version 2.0)DNV-GL Certificate of TM258, LMC058, TM5 (Version 2.0)REACh DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
ControllerDimensions -
Connections and Schema
TM5 System Wiring RecommendationsWire Sizes to Use with Removable Spring Terminal BlocksExternal Power SuppliesWiring Diagram of the Controller Power Distribution Module(1)Internal electronics(2)24 Vdc I/O power segment integrated into the bus bases(3)PS1/PS2: External isolated SELV power supply 24 Vdc(4)External fuse, Type T slow-blow, 3 A 250 V(5)External fuse, Type T slow-blow, 2 A 250 V(6)External fuse, Type T slow-blow, 10 A max., 250 V