Global (English)

Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

compact base M258 - 42 I/O - 24 V DC - Relay - CANopen - solution

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Modicon M258
    product or component type
    Logic controller
    product specific application
    For solutions
    software function
    Applicatives functions blocks
    discrete I/O number
    42
    discrete output number
    12 for relay output
    4 for fast output
    Complementary
    discrete input number
    10 for fast input
    12 for input
    4 for regular input
    discrete input logic
    Sink for fast input
    Sink for regular input
    Source for input
    discrete input voltage
    24 V
    discrete input voltage type
    DC
    voltage state 1 guaranteed
    >= 15 V for fast input
    >= 15 V for fast output
    >= 15 V for regular input
    voltage state 0 guaranteed
    <= 5 V for fast input
    <= 5 V for fast output
    <= 5 V for regular input
    discrete input current
    4 mA for fast input
    4 mA for regular input
    input impedance
    6 kOhm for fast input
    6 kOhm for regular input
    configurable filtering time
    0 ms for fast input/regular input and fast output
    1.5 ms for fast input/regular input and fast output
    12 ms for fast input/regular input and fast output
    4 ms for fast input/regular input and fast output
    anti bounce filtering
    2 µs...4 ms (configurable) fast input/regular input and fast output
    cable distance between devices
    30 m for fast input
    30 m for fast output
    30 m for regular input
    isolation between channels and internal logic
    500 Vrms AC
    isolation between channels
    None
    discrete output logic
    Source
    discrete output voltage
    24 V DC
    output voltage limits
    19.2...28.8 V
    discrete output current
    4 mA for fast output
    [Us] rated supply voltage
    24 V DC for embedded expert modules power
    24 V DC for I/O power segment
    24 V DC for main supply
    supply voltage limits
    20.4...28.8 V
    [In] rated current
    0.04 A for embedded expert modules power
    0.33 A for main supply
    10 A for I/O power segment
    peak current
    <= 100 kA during <= 70 s main supply
    <= 25 kA during <= 500 s I/O power segment
    <= 50 kA during <= 150 s embedded expert modules power
    1.2 A during > 70 s main supply
    power consumption in W
    <= 17.22 W
    execution time per instruction
    22 ns : Boolean
    memory description
    Flash 128 MB
    Internal RAM 64 MB
    realtime clock
    With user calibration realtime clock, drift: <= 6 s/month
    Without any user calibration realtime clock, drift: < 30 s/month at 25 °C
    data backed up
    Variables of type retain and retain persistent CR2477M Renata, 1.5 years autonomy
    integrated connection type
    1 CANopen male SUB-D 9, CANopen master
    1 isolated serial link female RJ45, Ethernet Modbus TCP/IP slave (10BASE-T/100BASE-TX)
    2 free slots PCI
    1 isolated serial link female RJ45, Modbus master/slave RTU/ASCII or character mode ASCII (RS232/RS485), 300...115200 bps
    1 isolated serial link mini B USB, 480 Mbit/s
    1 isolated serial link USB type A, 480 Mbit/s
    transmission rate
    125 kbit/s for bus length of 500 m, CANopen
    250 kbit/s for bus length of 250 m, CANopen
    50 kbit/s for bus length of 1000 m, CANopen
    500 kbit/s for bus length of 100 m, CANopen
    10 kbit/s for bus length of 5000 m, CANopen
    1000 kbit/s for bus length of 4 m, CANopen
    20 kbit/s for bus length of 2500 m, CANopen
    800 kbit/s for bus length of 25 m, CANopen
    counting input number
    8 counting input(s) 200 kHz
    local signalling
    1 LED per channel for I/O state
    1 LED for CAN0 STS
    1 LED for MBS COM
    1 LED green/red for APP0
    1 LED green/red for APP1
    1 LED green/red for Eth NS (Ethernet network status)
    1 LED green/red for Eth ST (Ethernet status)
    1 LED green/red for RUN/MS (module status)
    1 LED green/red for USB host
    1 LED green/yellow for Eth LA (Ethernet activity)
    1 LED red for BATT (battery status)
    marking
    CE
    mounting support
    Symmetrical DIN rail
    width
    262.5 mm
    height
    99 mm
    depth
    85 mm
    product weight
    0.8 kg
    Environment
    standards
    UL 508
    IEC 61131-2
    CSA C22.2 No 142
    CSA C22.2 No 213
    product certifications
    C-Tick
    cULus
    CSA
    GOST-R
    ambient air temperature for operation
    0...55 °C without derating factor horizontal installation
    0...60 °C with derating factor horizontal installation
    0...50 °C vertical installation
    ambient air temperature for storage
    -25...70 °C
    relative humidity
    5...95 % without condensation
    IP degree of protection
    IP20 conforming to IEC 61131-2
    pollution degree
    2 conforming to IEC 60664
    operating altitude
    0...2000 m
    storage altitude
    0...3000 m
    vibration resistance
    1 gn 8.4...150 Hz DIN rail
    3.5 mm 5...8.4 Hz DIN rail
    shock resistance
    15 gn for 11 ms
    resistance to electrostatic discharge
    4 kV on contact conforming to EN/IEC 61000-4-2
    8 kV in air conforming to EN/IEC 61000-4-2
    resistance to electromagnetic fields
    1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3
    10 V/m 80...2000 MHz conforming to EN/IEC 61000-4-3
    resistance to fast transients
    1 kV I/O conforming to EN/IEC 61000-4-4
    1 kV shielded cable conforming to EN/IEC 61000-4-4
    2 kV power lines conforming to EN/IEC 61000-4-4
    surge withstand
    0.5 kV differential mode conforming to EN/IEC 61000-4-5
    1 kV common mode conforming to EN/IEC 61000-4-5
    disturbance radiated/conducted
    CISPR 11
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • French
    • Italian
    • Chinese
    • German
    User guide
    Date
    Size
    Add to My Documents
    SoMachine - Compatibilité et migration, Guide utilisateur (Version 06)
    Modicon M258 Logic Controller, Programming Guide (Version 09)
    SoMachine Compatibility and Migration, User Guide (Version 06)
    Modicon M258 Logic Controller, Guida alla programmazione (Version 09)
    SoMachine - Kompatibilität und Migration, Benutzerhandbuch (Version 06)
    Modicon M258 Logic Controller, 编程指南 (Version 09)
    Modicon M258 Logic Controller, Programmierhandbuch (Version 09)
    Modicon M258 Logic Controller, Guía de programación (Version 09)
    Modicon M258 Logic Controller, Guide de programmation (Version 09)
    Compatibilità e migrazione di SoMachine, Guida utente (Version 06)
    SoMachine - Compatibilidad y migración, Guía del usuario (Version 06)
    SoMachine 兼容性和迁移 用户指南 (Version 06)
    Certificate
    Date
    Size
    Add to My Documents
    RCM_SupplierDeclarationOfConformity_M258_TM5_TM7 (Version 1.0)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Lexium Declaration of Incorporation MAX - Series (Version 1.1)
    End of Life Information
    Date
    Size
    Add to My Documents
    TM258L... M258 Controller, Product End-of-Life Instructions (Version 1.0)
    M258 Logic Controller, Product End-of-Life Instructions (Version 2.0)
    Marine certificate
    Date
    Size
    Add to My Documents
    LR Marine Certificate of Modicon TM258 TM5 LMC058 PLCs (Version 2.0)
    DNV-GL Certificate of TM258, LMC058, TM5 (Version 2.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Controller
    Dimensions



  • Connections and Schema

    TM5 System Wiring Recommendations
    Wire Sizes to Use with Removable Spring Terminal Blocks



    External Power Supplies
    Wiring Diagram of the Controller Power Distribution Module


    (1)
    Internal electronics
    (2)
    24 Vdc I/O power segment integrated into the bus bases
    (3)
    PS1/PS2: External isolated SELV power supply 24 Vdc
    (4)
    External fuse, Type T slow-blow, 3 A 250 V
    (5)
    External fuse, Type T slow-blow, 2 A 250 V
    (6)
    External fuse, Type T slow-blow, 10 A max., 250 V