controller M241 24 IO relay Ethernet

Show more characteristics >
Add to My Products Add to My Products

  • Main
    range of product
    Modicon M241
    product or component type
    Logic controller
    [Us] rated supply voltage
    100...240 V AC
    discrete input number
    14 discrete input including 8 fast input conforming to IEC 61131-2 Type 1
    discrete output type
    Relay
    Transistor
    discrete output number
    6 relay
    4 transistor including 4 fast output
    discrete output voltage
    24 V DC for transistor output
    5...125 V DC for relay output
    5...250 V AC for relay output
    discrete output current
    2 A with Q4...Q9 terminal(s) for relay output
    0.1 A with TR0...TR3 terminal(s) for fast output (PTO mode)
    0.5 A with TR0...TR3 terminal(s) for transistor output
    Complementary
    discrete I/O number
    24
    number of I/O expansion module
    7 (local I/O architecture)
    14 (remote I/O architecture)
    supply voltage limits
    85...264 V
    network frequency
    50/60 Hz
    discrete input logic
    Sink or source
    discrete input voltage
    24 V
    discrete input voltage type
    DC
    voltage state 1 guaranteed
    >= 15 V for input
    voltage state 0 guaranteed
    <= 5 V for input
    discrete input current
    5 mA for input
    input impedance
    4.7 kOhm for input
    response time
    50 µs turn-on operation with I0...I13 terminal(s) for input
    configurable filtering time
    1 µs for fast input
    discrete output logic
    Positive logic (source)
    output voltage limits
    125 V DC relay output
    30 V DC transistor output
    277 V AC relay output
    output frequency
    <= 1 kHz for transistor output
    <= 20 kHz for fast output (PWM mode)
    <= 100 kHz for fast output (PLS mode)
    accuracy
    +/- 0.1 % at 0.02...0.1 kHz for fast output
    +/- 1 % at 0.1...1 kHz for fast output
    protection type
    Short-circuit protection for transistor output
    Short-circuit and overload protection with automatic reset for transistor output
    Reverse polarity protection for transistor output
    Without protection for relay output
    reset time
    10 ms automatic reset output
    12 s automatic reset fast output
    memory capacity
    8 MB for program
    64 MB for system memory RAM
    data backed up
    128 MB built-in flash memory for backup of user programs
    data storage equipment
    <= 16 GB SD card optional
    battery type
    BR2032 lithium non-rechargeable, battery life: 4 yr
    backup time
    2 years at 25 °C
    execution time for 1 KInstruction
    0.3 ms for event and periodic task
    0.7 ms for other instruction
    application structure
    8 event tasks
    4 cyclic master tasks
    3 cyclic master tasks + 1 freewheeling task
    8 external event tasks
    realtime clock
    With
    clock drift
    <= 60 s/month at 25 °C
    positioning functions
    PTO function 4 channel(s) (positioning frequency: 100 kHz)
    counting input number
    4 fast input (HSC mode) at 200 kHz
    14 standard input at 1 kHz
    control signal type
    A/B signal at 100 kHz for fast input (HSC mode)
    Pulse/direction signal at 200 kHz for fast input (HSC mode)
    Single phase signal at 200 kHz for fast input (HSC mode)
    integrated connection type
    USB port with connector mini B USB 2.0
    Ethernet with connector RJ45
    Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485
    Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485
    supply
    Serial link supply "serial 1" at 5 V, <= 200 mA
    transmission rate
    1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485
    1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232
    480 Mbit/s for bus length of 3 m - communication protocol: USB
    10/100 Mbit/s - communication protocol: Ethernet
    communication port protocol
    Modbus non isolated serial link with master/slave method
    port Ethernet
    1 - 10BASE-T/100BASE-TX port with copper cable support
    ethernet services
    FDR
    Downloading
    IEC VAR ACCESS
    Monitoring
    NGVL
    Programming
    Updating firmware
    SMS notifications
    DHCP server (via TM4 Ethernet switch network module)
    DHCP client (embedded Ethernet port)
    SNMP client/server
    FTP client/server
    SQL client
    Modbus TCP client I/O scanner
    Ethernet/IP originator I/O scanner (embedded Ethernet port)
    Ethernet/IP target, Modbus TCP server and Modbus TCP slave
    Send and receive email from the controller based on TCP/UDP library
    Web server (WebVisu & XWeb system)
    OPC UA server
    DNS client
    local signalling
    1 LED green for SD card access (SD)
    1 LED red for BAT
    1 LED green for SL1
    1 LED green for SL2
    1 LED per channel green for I/O state
    1 LED red for I/O error (I/O)
    1 LED red for bus fault on TM4 (TM4)
    1 LED green for Ethernet port activity
    1 LED red for module error (ERR)
    1 LED green for PWR
    1 LED green for RUN
    electrical connection
    Removable screw terminal block for inputs and outputs (pitch 5.08 mm)
    Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm)
    cable distance between devices
    Unshielded cable: <= 50 m for input
    Shielded cable: <= 10 m for fast input
    Unshielded cable: <= 50 m for output
    Shielded cable: <= 3 m for fast output
    insulation
    500 V AC between supply and internal logic
    Non-insulated between supply and ground
    marking
    CE
    sensor power supply
    24 V DC at 400 mA supplied by the controller
    surge withstand
    2 kV for power lines (AC) in common mode conforming to EN/IEC 61000-4-5
    2 kV for relay output in common mode conforming to EN/IEC 61000-4-5
    1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5
    1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5
    1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5
    1 kV for input in common mode conforming to EN/IEC 61000-4-5
    1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5
    web services
    Web server
    maximum number of connections
    8 connection(s) for Modbus server
    8 connection(s) for SoMachine protocol
    10 connection(s) for web server
    4 connection(s) for FTP server
    16 connection(s) for Ethernet/IP target
    8 connection(s) for Modbus client
    number of slave
    16 Ethernet/IP
    64 Modbus TCP
    cycle time
    10 ms 16 Ethernet/IP
    64 ms 64 Modbus TCP
    mounting support
    Top hat type TH35-15 rail conforming to IEC 60715
    Top hat type TH35-7.5 rail conforming to IEC 60715
    Plate or panel with fixing kit
    height
    90 mm
    depth
    95 mm
    width
    150 mm
    product weight
    0.53 kg
    Environment
    standards
    CSA C22.2 No 142
    ANSI/ISA 12-12-01
    UL 1604
    CSA C22.2 No 213
    EN/IEC 61131-2 : 2007
    Marine specification (LR, ABS, DNV, GL)
    UL 508
    product certifications
    CSA
    cULus
    IACS E10
    RCM
    resistance to electrostatic discharge
    4 kV on contact conforming to EN/IEC 61000-4-2
    8 kV in air conforming to EN/IEC 61000-4-2
    resistance to electromagnetic fields
    10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
    3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
    1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3
    resistance to fast transients
    2 kV for power lines conforming to EN/IEC 61000-4-4
    2 kV for relay output conforming to EN/IEC 61000-4-4
    1 kV for Ethernet line conforming to EN/IEC 61000-4-4
    1 kV for serial link conforming to EN/IEC 61000-4-4
    1 kV for input conforming to EN/IEC 61000-4-4
    1 kV for transistor output conforming to EN/IEC 61000-4-4
    resistance to conducted disturbances
    10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
    3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
    10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL)
    electromagnetic emission
    Conducted emissions, test level: 120...69 dBµV/m QP, condition of test: power lines (radio frequency: 10...150 kHz) conforming to EN/IEC 55011
    Conducted emissions, test level: 63 dBμV/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011
    Conducted emissions, test level: 79 dBμV/m QP/66 dBμV/m AV, condition of test: power lines (radio frequency: 0.15...0.5 MHz) conforming to EN/IEC 55011
    Conducted emissions, test level: 73 dBμV/m QP/60 dBμV/m AV, condition of test: power lines (radio frequency: 0.5...300 MHz) conforming to EN/IEC 55011
    Radiated emissions, test level: 40 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 30...230 MHz) conforming to EN/IEC 55011
    Conducted emissions, test level: 79...63 dBμV/m QP, condition of test: power lines (radio frequency: 150...1500 kHz) conforming to EN/IEC 55011
    Radiated emissions, test level: 47 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011
    immunity to microbreaks
    10 ms
    ambient air temperature for operation
    -10...55 °C for horizontal installation
    -10...50 °C for vertical installation
    ambient air temperature for storage
    -25...70 °C
    relative humidity
    10...95 % without condensation in operation
    10...95 % without condensation in storage
    IP degree of protection
    IP20 with protective cover in place
    pollution degree
    2
    operating altitude
    0...2000 m
    storage altitude
    0...3000 m
    vibration resistance
    3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
    3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail
    3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting
    3 gn (vibration frequency: 8.4...150 Hz) on panel mounting
    shock resistance
    15 gn for 11 ms
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • Chinese
    • German
    • Turkish
    Catalogue
    Date
    Size
    Add to My Documents
    Contrôleurs logiques Modicon M241 (Version 4.0)
    User guide
    Date
    Size
    Add to My Documents
    Modicon M241 Logic Controller, Guida alla programmazione (Version 07)
    Modicon M241 Logic Controller - System Functions and Variables PLCSystem, Library Guide (Version 04)
    Modicon M241 Logic Controller, Programming Guide (Version 07)
    Modicon M241 Logic Controller - PTOPWM, Library Guide (Version 07)
    Modicon TM4 Expansion Modules, Hardware Guide (Version 04)
    Modicon M241 Logic Controller, PTOPWM Bibliothekshandbuch (Version 07)
    Modicon TM4 Expansion Modules, Programming Guide (Version 03)
    Modicon M241 Logic Controller, Guide de la bibliothèque PTOPMW (Version 07)
    Modicon M241 Logic Controller, Guía de programación (Version 07)
    Modicon TM4 扩展模块 编程指南 (Version 03)
    Modicon TM4 - Moduli di espansione, Guida alla programmazione (Version 03)
    Modicon TM4 - 扩展模块 硬件指南 (Version 04)
    Modicon M241 Logic Controller, PTOPWM 库指南 (Version 07)
    Modicon M241 Logic Controller, Guide de référence du matériel (Version 07)
    Modicon M241 Logic Controller, PTOPWM Guía de la biblioteca (Version 07)
    Modicon TM4 - Módulos de ampliación, Guía de hardware (Version 04)
    Modicon M241 Logic Controller - Contador de alta velocidad, Guía de la biblioteca HSC (Version 04)
    Modicon M241 Logic Controller - 高速计数 HSC 库指南 (Version 04)
    Modicon TM4 - Erweiterungsmodule, Programmierhandbuch (Version 03)
    Modicon M241 Logic Controller, 编程指南 (Version 07)
    Modicon M241 Logic Controller - Funzioni di sistema e variabili, Guida della libreria PLCSystem (Version 04)
    Modicon M241 Logic Controller - 系统功能和变量 PLCSystem 库指南 (Version 04)
    Modicon M241 Logic Controller - Funciones y variables del sistema, Guía de la biblioteca PLCSystem (Version 04)
    Modicon M241 Logic Controller - Systemfunktionen und -Variablen, PLCSystem-Bibliothekshandbuch (Version 04)
    Material Handling - Conveying M241, Project Template User Guide (Version 00)
    Modicon M241 Logic Controller, Programmierhandbuch (Version 07)
    Modicon M241 Logic Controller, Guida hardware (Version 07)
    Modicon TM4 - Modules d’extension, Guide de programmation (Version 03)
    Modicon M241 Logic Controller - Conteggio ad alta velocità, Guida della libreria HSC (Version 04)
    Modicon M241 Logic Controller - Comptage rapide, Guide de la bibliothèque HSC (Version 04)
    Modicon TM4 - Moduli di espansione, Guida hardware (Version 04)
    Modicon TM4 - Módulos de ampliación, Guía de programación (Version 03)
    Modicon M241 Logic Controller, Guía de hardware (Version 07)
    Modicon M241 Logic Controller 硬件指南 (Version 07)
    Modicon M241 Logic Controller - High Speed Counting, HSC Library Guide (Version 04)
    Modicon M241 Logic Controller, Hardware Guide (Version 07)
    Modicon M241 Logic Controller - Fonctions et variables système, Guide de la bibliothèque PLCSystem (Version 04)
    Modicon M241 Logic Controller, Guide de programmation (Version 07)
    Modicon TM4 - Modules d’extension, Guide de référence du matériel (Version 04)
    Modicon M241 Logic Controller, Hardwarehandbuch (Version 07)
    Modicon TM4 - Erweiterungsmodule, Hardwarehandbuch (Version 04)
    Modicon M241 Logic Controller, PTOPWM Guida della libreria (Version 07)
    Modicon M241 Logic Controller - Hochgeschwindigkeitszählung, HSC-Bibliothekshandbuch (Version 04)
    CAD
    Date
    Size
    Add to My Documents
    CAD files for TM241CE24R: CONTROLLER M241-24IO Relay Ethernet (Version 1.0)
    Compact Hardwired Logic Controller M241 - Wiring Diagram (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    UL Certificate Ordinary Location TM241 TM251 TMC4 TM3X (Version 1.0)
    UL Certificate Haz. Loc. TM241 TMC4 (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    M241 AC Logic Controller - Instruction sheet (Version 03)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Modicon DoC TM241 (Version 1.2)
    Date 5/3/18
    Size 374.7 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    TM241C... Modicon M241 Logic Controller, Product End-of-Life Instructions (Version 3.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 2/21/19
    Size 0
    Firmware - Released
    Date
    Size
    Add to My Documents
    M241 M251 Firmware (Version 4.0.6.38)
    Date 1/11/19
    Size 8.8 MB
    Date 1/11/19
    Size 5.2 MB
    Date 1/11/19
    Size 5.3 MB
    Date 1/11/19
    Size 16.9 MB
    Date 1/11/19
    Size 568 KB
    M241 M251 Firmware (Version 4.0.6.39)
    Date 1/31/19
    Size 612.5 KB
    Date 1/31/19
    Size 5.3 MB
    Date 1/31/19
    Size 16.9 MB
    Date 1/31/19
    Size 8.8 MB
    Date 1/31/19
    Size 5.3 MB
    Firmware - Updates
    Date
    Size
    Add to My Documents
    Last Release Notes (Version 4.0.6.39)
    Date 1/14/19
    Size 612.5 KB
    Marine certificate
    Date
    Size
    Add to My Documents
    DNV GL Type Approval TM241 TM251 (Version 1.1)
    ABS Marine Certificate Modicon M241 M251 PLCs (Version 1.1)
    LR Marine Certificate Modicon TM241/251 PLCs (Version 2.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    TM241C... Modicon M241 Logic Controller, Product Environmental Profile (Version 3.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 2/21/19
    Size 0
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



  • Mounting and Clearance

    Clearance



    Mounting Position


    Acceptable Mounting


    NOTE: Expansion modules must be mounted above the logic controller.

    Incorrect Mounting



    Direct Mounting On a Panel Surface
    Mounting Hole Layout



  • Connections and Schema

    Digital Inputs
    Wiring Diagram (Positive Logic)


    (*) :
    Type T fuse
    (1) :
    The COM0, COM1 and COM2 terminals are not connected internally.

    Wiring Diagram (Negative Logic)


    (*) :
    Type T fuse
    (1) :
    The COM0, COM1 and COM2 terminals are not connected internally.


    Fast Transistor Outputs
    Wiring Diagram


    (*) :
    2 A fast-blow fuse


    Relay Outputs
    Wiring Diagram


    (*) :
    Type T fuse
    (1) :
    The terminals COM1 to COM4 are not connected internally.
    (2) :
    To improve the life time of the contacts, and to protect from potential inductive load damage, you must connect a free wheeling diode in parallel to each inductive DC load or an RC snubber in parallel of each inductive AC load


    USB Mini-B Connection



    Ethernet Connection to a PC