Global (English)

Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

Symmetra PX 96kW Scalable to 160kW, without Bypass, Distribution, or Batteries, 400V

Show more characteristics >
Add to My Products Remove from My Products

  • Overview
    Description
    A high-efficiency, modular 3-phase UPS that offers internal redundancy for your data center requirements. With scalable power, this UPS grows with your data center up to 160kW/kVA. Pair with the Classic Battery Cabinet and the Wall-Mount or 300mm Maintenance Bypass Panel to complete your power protection solution. Please click here for Classic Battery Cabinet runtime information. Suitable for small to medium data centers or individual zones of large data centers.
    Model Name
    Symmetra PX 96kW Scalable to 160kW, without Bypass, Distribution, or Batteries, 400V
    Includes
    Network Management Card , Start-Up Service , User Manual
    Standard Lead Time
    Usually Ships within 3 Weeks
    Product Distribution
    Albania , Algeria , Andorra , Angola , Anguilla , Antigua And Barbuda , Argentina , Armenia , Aruba , Australia , Austria , Azerbaijan , Bahamas , Bahrain , Barbados , Belarus , Belgium , Belize , Benin , Bermuda , Bolivia , Bosnia And Herzegovina , Botswana , Brazil , Bulgaria , Burkina Faso , Burundi , Cameroon , Cayman Islands , Central African Republic , Chad , Chile , China , Colombia , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Costa Rica , Cote D'Ivoire , Croatia , Cuba , Cyprus , Czech Republic , Denmark , Djibouti , Dominica , Dominican Republic , Ecuador , Egypt , El Salvador , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Falkland Islands (Malvinas) , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Grenada , Guadeloupe , Guatemala , Guinea , Guyana , French Guiana , Haiti , Honduras , Hong Kong , Hungary , Iceland , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Jordan , Kazakhstan , Kenya , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Mexico , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Namibia , Netherlands , Netherlands Antilles , New Zealand , Nicaragua , Niger , Nigeria , Norway , Oman , Pakistan , Panama , Paraguay , Peru , Poland , Portugal , Puerto Rico , Qatar , Reunion , Romania , Russian Federation , Rwanda , SAINT KITTS AND NEVIS , SAINT LUCIA , SAINT VINCENT AND THE GRENADINES , Saudi Arabia , Senegal , Sierra Leone , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sudan , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Togo , Trinidad And Tobago , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , Uruguay , Uzbekistan , Venezuela , VIRGIN ISLANDS (UNITED STATES) , Western Sahara , Yemen , Zambia , Zimbabwe
    General
    Bypass Connection
    5 wire (3PH + N + G)
    Max Bypass Input Current
    250 A
    Bypass Protection Device
    250 A
    Output
    Output Power Capacity
    96.0 KW / 96.0 kVA
    Max Configurable Power (Watts)
    160.0 KW / 160.0 kVA
    Nominal Output Voltage
    230V , 400 3PH
    Output Voltage Note
    Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
    Output Voltage Distortion
    Less than 2%
    Output Frequency (sync to mains)
    50/60 Hz +/- 3 Hz user adjustable +/- 0.1
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Connections
    (1) Hard Wire 5-wire (3PH + N + G) (Battery Backup)
    Output Voltage Tolerance
    +/-1% static and +/- 5% at 100% load step
    Output Voltage THD
    < 2% for 0 to 100% linear load and < 5% for full non linear load
    Overload Operation
    10 minutes @ 125% and 60 seconds @ 150%
    Required Output Current Protection
    250 A
    Neutral Output Current
    240 A
    Bypass
    Built-in Static Bypass
    Input
    Nominal Input Voltage
    400 3PH
    Input Frequency
    40 - 70 Hz
    Input Connections
    Hard Wire 5-wire (3PH + N + G)
    Input voltage range for main operations
    340 - 477 V
    Maximum Input Current
    197 A
    Input Breaker Capacity
    315 A
    Maximum Short Circuit Withstand (Icw)
    30.0
    Input Total Harmonic Distortion
    Less than 5% for full load
    Batteries & Runtime
    Battery Type
    No internal battery - uses external battery system
    Replacement Battery
    SYPX160CLASSICBATTCAB
    Efficiency in Battery Operation
    94.00 %
    Communications & Management
    Interface Port(s)
    DB-9 RS-232 , SmartSlot
    Available SmartSlot™ Interface Quantity
    2
    Control panel
    Multi-function LCD status and control console
    Audible Alarm
    Alarm when on battery : distinctive low battery alarm : configurable delays
    Emergency Power Off (EPO)
    Yes
    Physical
    Maximum Height
    1991.0 mm
    Maximum Width
    600.0 mm
    Maximum Depth
    1070.0 mm
    Rack Height
    42 U
    Net Weight
    496.0 kg
    Shipping Weight
    547.0 kg
    Shipping Height
    2140.0 mm
    Shipping Width
    848.0 mm
    Shipping Depth
    1210.0 mm
    Color
    Black
    Environmental
    Operating Environment
    0 - 40 °C
    Operating Relative Humidity
    0 - 95 %
    Operating Elevation
    0-999.9 meters
    Storage Temperature
    -15 - 40 °C
    Storage Relative Humidity
    0 - 95 %
    Storage Elevation
    0-15000 meters
    Audible noise at 1 meter from surface of unit
    63.000 dB
    Online Thermal Dissipation
    17244.000 BTU/hr
    Protection Class
    IP 20 , NEMA 1
    Conformance
    Approvals
    EN 50091-1 , EN/IEC 62040-1-1 , EN/IEC 62040-2 , EN/IEC 62040-3 , ISO 14001 , ISO 9001 , VFI-SS-111
    Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Latvian
    • Danish
    • Slovenian
    • French
    • Finnish
    • Serbian
    • Chinese
    • Dutch
    • Norwegian
    • Russian
    • Greek
    • Lithuanian
    • Croatian
    • Italian
    • German
    • Estonian
    Catalogue
    Date
    Size
    Add to My Documents
    Symmetra PX 96/160kW Brochure (Version 6)
    User guide
    Date
    Size
    Add to My Documents
    Symmetra PX 96 kW & 160 kW 400 V Установка (Version 3)
    Symmetra PX 96 kW & 160 kW 400 V Montage (Version 3)
    Schneider Electric Important Safety Instructions (Version 0)
    Symmetra PX 48-160 kW Release Note (Version 1)
    Symmetra PX 96 kW and 160 kW 400 V Installation (Version 3)
    Symmetra PX 96 kW & 160 kW 400 V Manuel d'installation (Version 3)
    Symmetra PX 96 kW & 160 kW 400 V Impianto (Version 3)
    Symmetra PX 96 kW & 160 kW 400 V 安装 (Version 3)
    Symmetra PX 96 kW & 160 kW 400 V Instalación (Version 3)
    CAD
    Date
    Size
    Add to My Documents
    SYCF160KH - Symmetra PX 160kW 400V, UPS (Version 3)
    SYCF160KH-NB - Symmetra_PX160kW_UPS_without_Bypass_Distribution or Batteries_400V (Version 0)
    SYPBV96K160HB - Symmetra PX-ET,160kW, Battery Cabinet with XPV2500 Batteries (Version 0)
    SYWMBP96K160H2-Symmetra PX ET 96-160kW Wall mounted Maintenance Bypass Panel 400V (Version 0)
    SY96K160WMBPH2-SD - Symmetra_PX_96K160kW_Single_Mains_with_Value_Wall-Mounted_Maintenance_Bypass_Panel_System_Single_Line_Diagram (Version 0)
    SYPBV96K160HA - Symmetra PX-ET,160kW, Battery Cabinet with XP12V1800 Batteries (Version 0)
    SYPBV96K160H - Symmetra PX-ET,160kW, Battery Cabinet for Third-Party Batteries (Version 1)
    UPS_SYCF160KH_Symmetra_PX_160_Schneider_Electric_160kVA_400V_BIM_Model (Version 0)
    Certificate
    Date
    Size
    Add to My Documents
    Symmetra PX 48 kW, 96 kW, and 160 kW EU Declaration of Conformity (Version 3)
    Symmetra PX 48, Symmetra PX 96-160 kW 400 V Certificate of Origin (Version 3)
    Warranty
    Date
    Size
    Add to My Documents
    990-3017F Symmetra PX 96 kW and 160 kW 400 V Installation (Version 0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.