Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Smart-UPS VT
Schneider Electric SUVTP10KH Image
Discontinued

SUVTP10KH

Schneider Electric SUVTP10KH Image
Discontinued
SUVTP10KH

APC Smart-UPS VT 10kVA 400V, w/Internal Maintenance Bypass & Parallel Capability

Show more characteristics >
SUVTP10KH_APC  has not been replaced. Please contact your customer care center for more information.
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Overview
    Model Name
    APC Smart-UPS VT 10kVA 400V, w/Internal Maintenance Bypass & Parallel Capability
    Includes
    Bolt down brackets , CD with software , Installation guide , Network Management Card , Power modules ship installed , User Manual
    Standard Lead Time
    Special Order - Call for Quoted Lead Times
    Product Distribution
    Afghanistan , Albania , Algeria , Andorra , Angola , Armenia , Australia , Austria , Azerbaijan , Bahrain , Bangladesh , Belarus , Belgium , Benin , Bhutan , Bosnia And Herzegovina , Botswana , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Cayman Islands , Central African Republic , Chad , China , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Cote D'Ivoire , Croatia , Cyprus , Czech Republic , Denmark , Djibouti , East Timor , Egypt , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Guinea , Hong Kong , Hungary , Iceland , India , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jordan , Kazakhstan , Kenya , KOREA, REPUBLIC OF , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Malawi , Malaysia , Mali , Malta , Mauritania , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , New Zealand , Niger , Nigeria , Norway , Oman , Pakistan , Papua New Guinea , Philippines , Poland , Portugal , Romania , Russian Federation , Rwanda , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sri Lanka , Sudan , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Turkey , Turkmenistan , Uganda , Ukraine , United Arab Emirates , Uzbekistan , Viet Nam , Western Sahara , Yemen , Zambia , Zimbabwe
    General
    Bypass Connection
    5 wire (3PH + N + G)
    Bypass Voltage Tolerance
    +/-10% settable from +/-4/6/8 and 10%
    Output
    Output Power Capacity
    8000 Watts / 10.0 kVA
    Max Configurable Power (Watts)
    8000 Watts / 10.0 kVA
    Nominal Output Voltage
    230V , 400 3PH
    Output Voltage Note
    Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
    Output Voltage Distortion
    Less than 5% at full load
    Output Frequency (sync to mains)
    47 - 53 Hz for 50 Hz nominal
    Other Output Voltages
    380, 415V
    Crest Factor
    Unlimited
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Connections
    (1) Hard Wire 4-wire (3PH + G) (Battery Backup) , (1) Hard Wire 5-wire (3PH + N + G) (Battery Backup) , (1) Screw Terminals (Battery Backup)
    Output Voltage THD
    < 2% for 0 to 100% linear load and < 5% for full non linear load
    Overload Operation
    10 minutes @ 125% and 30 seconds @ 150%
    Bypass
    Built-in Maintenance Bypass , Built-in Static Bypass
    Input
    Nominal Input Voltage
    400 3PH
    Input Frequency
    47 - 70 Hz (auto sensing)
    Input Connections
    Hard Wire 5-wire (3PH + N + G)
    Input voltage range for main operations
    304 - 477 V
    Other Input Voltages
    380 , 415
    Maximum Input Current
    14 A
    Input Breaker Capacity
    20 A
    Maximum Short Circuit Withstand (Icw)
    30.0
    Input Total Harmonic Distortion
    Less than 5% for full load
    Type of Input Protection Required
    3-pole breaker
    Batteries & Runtime
    Battery Type
    No internal battery - uses external battery system
    Typical recharge time
    5 hour(s)
    Replacement Battery
    SYBT4
    Communications & Management
    Interface Port(s)
    DB-9 RS-232 , SUVTPCOM , SmartSlot
    Pre-Installed SmartSlot™ Cards
    AP9619
    Control panel
    Multi-function LCD status and control console
    Audible Alarm
    Audible and visible alarms prioritized by severity
    Emergency Power Off (EPO)
    Yes
    Physical
    Maximum Height
    823.0 mm
    Maximum Width
    352.0 mm
    Maximum Depth
    838.0 mm
    Net Weight
    134.0 kg
    Shipping Weight
    173.0 kg
    Shipping Height
    1290.0 mm
    Shipping Width
    720.0 mm
    Shipping Depth
    1110.0 mm
    Color
    Black
    Units per Pallet
    1.0
    Environmental
    Operating Environment
    0 - 40 °C
    Operating Relative Humidity
    0 - 95 %
    Operating Elevation
    0-999.9 meters
    Storage Temperature
    -35 - 60 °C
    Storage Relative Humidity
    0 - 95 %
    Storage Elevation
    0-15000 meters
    Audible noise at 1 meter from surface of unit
    64.000 dB
    Online Thermal Dissipation
    1501.000 BTU/hr
    Protection Class
    IP 20
    Conformance
    Approvals
    C-tick , CE , EN 50091-2 , EN/IEC 62040-3 , IEC 61000-3-2 , IEC 61000-3-3 , ISO 14001 , ISO 9001 , VFI-SS-112
    Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • Chinese
    • German
    • Dutch
    Catalogue
    Date
    Size
    Add to My Documents
    Brochure Smart UPS -VT 50hz (Version 1)
    Date 12/11/18
    Size 721.5 KB
    User guide
    Date
    Size
    Add to My Documents
    MGE Galaxy 3500, MGE Galaxy 300 and Smart-UPS VT Earthing Principles (Version 0)
    Funcionamiento de Smart-UPS VT 10-40 kVA 380/400/41 V, 208/220 V, 200/208 V (Version 0)
    Smart-UPS VT 10–40 кВА 380/400/415 В, 208/220 В, 200/208 В (Version 0)
    Smart-UPS VT 10-40 kVA, 380/400/41 V, 208/220 V, 200/208 V - Uso (Version 0)
    Smart-UPS VT 10-40 kVA, 380/400/415 V, 208/220 V, 200/208 V, Bedienung (Version 0)
    Smart-UPS VT 10-40 kVA 380/400/41 V, 208/220 V, 200/208 V Operation (Version 0)
    Utilisation de l'onduleur Smart-UPS VT 10-40 kVA 380/400/41 V, 208/220 V, 200/208 V (Version 0)
    Smart-UPS VT(10-40kVA,380/400/41V,208/220V)——操作 (Version 0)
    SHT UNPKG SUVT BATTS 10-40KVA GLOBAL (Version 1)
    Smart-UPS VT 10-40 kVA 380/400/415 V Installation (Version 0)
    CAD
    Date
    Size
    Add to My Documents
    SUVTPMBP10K40H-4MOD-WD - System Wiring Diagram (Version 0)
    SUVTPMBP10K40H-2MOD-WD - System Wiring Diagram (Version 0)
    SUVTPMBP10K40H-3MOD-WD - System Wiring Diagram (Version 0)
    Brochure
    Date
    Size
    Add to My Documents
    Smart UPS -VT( 50hz)宣传册 (Version 1)
    Specification guide
    Date
    Size
    Add to My Documents
    Smart-UPS VT 10-40 kVA 380/400/415 技术规格 (Version 0)
    Smart-UPS VT 10-40 kVA 380/400/415 Especificaciones técnicas (Version 0)
    Smart-UPS VT 10-40 kVA 380/400/415 Технические характеристики (Version 0)
    Smart-UPS VT 10-40 kVA 380/400/415 Especificações técnicas (Version 0)
    Smart-UPS VT 10-40 kVA 380/400/415 Specifiche tecniche (Version 0)
    Smart-UPS VT 10-40 kVA 380/400/415 Technische Daten (Version 0)
    Smart-UPS VT 10-40 kVA 380/400/415 Caractéristiques techniques (Version 0)
    Smart-UPS VT 10-40 kVA 380/400/415 V Technical Specifications (Version 0)
    Smart-UPS VT 10-40 kVA 380/400/415 Technische specificaties (Version 0)
    Certificate
    Date
    Size
    Add to My Documents
    Certificate of Origin Smart-UPS VT 3-Phase, 10-40 kVA, 400 V, 50 Hz (Sheet) (Version 1)
    Smart-UPS VT Cmim Declaration of Conformity (Version 0)
    Office of Statewide Health Planning and Development (OSHPD) Preapproval Galaxy 3500 and SUVT (Version 1)
    Certificate of Origin Smart-UPS VT 3-Phase, 10-40 kVA, 400 V, 50 Hz (Sheet) (Version 1)
    Smart-UPS VT 10-40 kVA EU Declaration of Conformity (Version 2)
    Specification for tender
    Date
    Size
    Add to My Documents
    Smart-UPS VT, w/Parallel Operation, 400V (Version 2)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /