Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Modicon STB
Schneider Electric STBART0200K Image

STBART0200K

Schneider Electric STBART0200K Image
STBART0200K

standard analog input kit STB - 2 I - 15 bits + sign

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon STB distributed I/O solution
    product or component type
    Standard analog input kit
    kit composition
    STBXTS2100, 6-terminal spring clamp connector
    STBXBA1000 base
    STBXTS1100, 6-terminal screw type connector
    STBART0200 module
    analogue input type
    Voltage +/- 80 mV
    Temperature probe -100...+260 °C Cu 10 2, 3 or 4 wires IEC
    Temperature probe -100...+450 °C Pt 100 2, 3 or 4 wires US/JIS
    Temperature probe -100...+450 °C Pt 1000 2, 3 or 4 wires US/JIS
    Temperature probe -200...+850 °C Pt 100 2, 3 or 4 wires IEC
    Temperature probe -200...+850 °C Pt 1000 2, 3 or 4 wires IEC
    Temperature probe -60...+180 °C Ni 100 2, 3 or 4 wires IEC
    Temperature probe -60...+180 °C Ni 1000 2, 3 or 4 wires IEC
    Thermocouple +130...+1820 °C thermocouple B
    Thermocouple -200...+760 °C thermocouple J
    Thermocouple -270...+1000 °C thermocouple E
    Thermocouple -270...+1370 °C thermocouple K
    Thermocouple -270...+400 °C thermocouple T
    Thermocouple -50...+1665 °C thermocouple R
    Thermocouple -50...+1665 °C thermocouple S
    analogue input number
    2
    analogue input resolution
    15 bits + sign
    type of filter
    Single low pass input filter 25 Hz
    Complementary
    absolute maximum input
    +/- 7.5 V DC
    cold swapping
    Yes
    hot swapping fallback
    Yes for standard NIMs
    fallback status
    State 0 basic NIMs
    User configurable standard NIMs
    data format
    EN 61131-2
    IEC 61131-2
    input impedance
    10 MOhm +/- 80 mV
    supply current for sensors
    100 mA per input channels
    protection type
    Short-circuit protection
    absolute accuracy error
    +/- 0.1 % of full scale 25 °C internal
    +/- 0.15 % of full scale 25 °C external
    insulation between channels and logic bus
    1500 V for 1 minute
    addressing requirement
    1 word for cold-junction compensation
    2 input words
    product compatibility
    Power distribution module STBPDT3100/3105
    Mounting base STBXBA1000
    [Us] rated supply voltage
    24 V DC
    supply
    Power distribution module
    current consumption
    30 mA 5 V DC logic bus
    measurement resolution
    0.01 mV voltage
    0.1 °C or 0.1 °F temperature probe
    0.1 °C or 0.1 °F thermocouple
    conversion time
    150 ms voltage 60 Hz
    170 ms voltage 50 Hz
    180 ms temperature probe 60 Hz 2 or 4 wires
    200 ms temperature probe 50 Hz 2 or 4 wires
    210 ms thermocouple with internal cold-junction compensation 60 Hz
    230 ms thermocouple with internal cold-junction compensation 50 Hz
    300 ms temperature probe 60 Hz 3 wires
    340 ms temperature probe 50 Hz 3 wires
    360 ms thermocouple with external cold-junction compensation 60 Hz
    400 ms thermocouple with external cold-junction compensation 50 Hz
    maximum wiring resistance
    20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires
    20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires
    20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires
    200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires
    200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires
    50 Ohm Cu 10 IEC/US/JIS 4 wires
    50 Ohm Ni 100 IEC/US/JIS 4 wires
    50 Ohm Pt 100 IEC/US/JIS 4 wires
    500 Ohm Ni 1000 IEC/US/JIS 4 wires
    500 Ohm Pt 1000 IEC/US/JIS 4 wires
    measurement accuracy
    +/- 1 °C Ni 100 25 °C external
    +/- 1 °C Ni 100 25 °C internal
    +/- 1 °C Ni 1000 25 °C external
    +/- 1 °C Ni 1000 25 °C internal
    +/- 1 °C Pt 100 25 °C internal
    +/- 1 °C Pt 1000 25 °C internal
    +/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C
    +/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C
    +/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C
    +/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C
    +/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C
    +/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C
    +/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C
    +/- 2 °C Pt 100 25 °C external
    +/- 2 °C Pt 1000 25 °C external
    +/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C
    +/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C
    +/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C
    +/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C
    +/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C
    +/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C
    +/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C
    +/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C
    +/- 4 °C Cu 10 25 °C external
    +/- 4 °C Cu 10 25 °C internal
    +/- 4 °C thermocouple K with internal cold-junction compensation 25 °C
    +/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C
    +/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C
    +/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C
    +/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C
    +/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C
    +/- 5 °C thermocouple S with internal cold-junction compensation 60 °C
    +/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C
    +/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C
    +/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C
    +/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C
    +/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C
    +/- 7 °C thermocouple J with internal cold-junction compensation 60 °C
    marking
    CE
    overvoltage category
    II
    status LED
    1 LED green module status (RDY)
    1 LED red module error (ERR)
    Environment
    product certifications
    UL
    C-Tick
    CSA
    ATEX Cat 3G
    FM Class 1 Division 2
    pollution degree
    2 IEC 60664-1
    operating altitude
    <= 2000 m
    IP degree of protection
    IP20 EN 61131-2 class 1
    ambient air temperature for operation
    0...70 °C
    ambient air temperature for operation
    32...140 °F without derating
    ambient air temperature for storage
    -40...85 °C without derating
    ambient air temperature for storage
    -40...185 °F without derating
    relative humidity
    95 % 60 °C without condensation
    vibration resistance
    +/-0.35 mm 10...58 Hz
    3 gn 58...150 Hz 35 x 7.5 mm symmetrical DIN rail
    5 gn 58...150 Hz 35 x 15 mm symmetrical DIN rail
    shock resistance
    30 gn 11 ms IEC 88 reference 2-27
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  0825  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Reference contains SVHC above the threshold  -  Go to CaP for more details
    Go to CaP for more details
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    Catalogue
    Date
    Size
    Add to My Documents
    Catalogue Modicon M580 Automation platform - English version (Version 6.1)
    Catalogue Plate-forme dautomatisme Modicon M580 (Version 6.0)
    Certificate
    Date
    Size
    Add to My Documents
    Hazloc_cCSAus_225844_700136731_STB_nov2017 (Version 1.0)
    CSA_225844_2591645_STB_AUG2017 (Version 1.0)
    Date 8/23/17
    Size 42.2 KB
    UL E486184 - NRAQ-NRAQ7 (Version 1.0)
    Date 12/12/18
    Size 395.6 KB
    EAC_RUCFRME83B00132_STB (Version 1.0)
    Date 7/29/14
    Size 1.9 MB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    DCC_STB_JUL2016 (Version 1.0)
    Date 7/20/16
    Size 481.7 KB
    ACMA_RCM_STB_FEB2015 (Version 1.0)
    Date 2/10/15
    Size 1.9 MB
    End of Life Information
    Date
    Size
    Add to My Documents
    Modicon STB IP20 distrbuted inputs/outputs and power modules, Product End-of-Life Instructions (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 9/19/19
    Size 195.3 KB
    Marine certificate
    Date
    Size
    Add to My Documents
    ABS Marine Certificate Advantys STB PLCs (Version 1.0)
    DNV-GL_TAA0000064_STB_NOV2015 (Version 1.0)
    Date 11/4/15
    Size 289.6 KB
    LR_16-20015_STB_FEB2016 (Version 1.0)
    Date 2/16/16
    Size 318.7 KB
    Date 2/16/16
    Size 104 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Modicon STB IP20 distrbuted inputs/outputs and power modules, Product Environmental Profile (Version 1.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 9/19/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



  • Connections and Schema

    Wiring Diagrams
    Examples

    2 and 3-wire temperature probes


    4-wire temperature probes


    2-wire temperature probes in highly disturbed environments


    2-wire thermocouple and voltage sensor (mV)


    2-wire thermocouple and voltage sensor (mV) with cold-junction compensation


    Pin

    Top Connections

    Bottom Connections

    1

    no connection

    no connection

    2

    Always used for RTD +

    Always used for RTD +

    RTD + connection for external cold-junction compensation on a TC sensor

    no connection for TC or mV

    no connection for TC or mV

    3

    TC + or mV + connection

    TC + or mV + connection

    Either used or jumpered for a two-, three-, or four-wire RTD

    Either used or jumpered for a two-, three-, or four-wire RTD

    4

    TC - or mV - connection

    TC - or mV - connection

    Either used or jumpered for a two-, three-, or four-wire RTD

    Either used or jumpered for a two-, three-, or four-wire RTD

    5

    Always used for RTD -

    Always used for RTD -

    RTD - connection for external cold-junction compensation on a TC sensor

    no connection for TC or mV

    no connection for TC or mV

    6

    inner double-shield cable

    cable shield


Compare products: /