Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Smart Relay - Zelio Logic SR2/SR3
Schneider Electric SR2D101FU Image

SR2D101FU

Green premium brand logo
Schneider Electric SR2D101FU Image
SR2D101FU
Green premium brand logo

compact smart relay Zelio Logic - 10 I O - 100..240 V AC - no clock - no display

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Logic
    product or component type
    Compact smart relay
    Complementary
    local display
    Without
    number or control scheme lines
    240 with ladder programming
    cycle time
    6…90 ms
    backup time
    10 years at 25 °C
    clock drift
    12 min/year at 0…55 °C
    6 s/month at 25 °C
    checks
    Program memory on each power up
    [Us] rated supply voltage
    100...240 V AC
    supply voltage limits
    85…264 V
    supply frequency
    50/60 Hz
    maximum supply current
    30 mA at 240 V (without extension)
    80 mA at 100 V (without extension)
    power consumption in VA
    7 VA without extension
    isolation voltage
    1780 V
    protection type
    Against inversion of terminals (control instructions not executed)
    discrete input number
    6
    discrete input voltage
    100...240 V AC
    discrete input current
    0.6 mA
    discrete input frequency
    47...53 Hz
    57...63 Hz
    voltage state 1 guaranteed
    >= 79 V for discrete input
    voltage state 0 guaranteed
    <= 40 V for discrete input
    current state 1 guaranteed
    >= 0.17 mA (discrete input)
    current state 0 guaranteed
    <= 0.5 mA (discrete input)
    input impedance
    350 kOhm for discrete input
    number of outputs
    4 relay
    output voltage limits
    5...30 V DC (relay output)
    24...250 V AC
    contacts type and composition
    NO for relay output
    output thermal current
    8 A for all 4 outputs for relay output
    electrical durability
    AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    switching capacity in mA
    >= 10 mA at 12 V (relay output)
    operating rate in Hz
    0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    mechanical durability
    10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage
    4 kV EN/IEC 60947-1 and EN/IEC 60664-1
    clock
    Without
    response time
    50 ms with ladder programming (from state 0 to state 1) for discrete input
    50 ms with ladder programming (from state 1 to state 0) for discrete input
    50...255 ms with FBD programming (from state 0 to state 1) for discrete input
    50...255 ms with FBD programming (from state 1 to state 0) for discrete input
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    connections - terminals
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid
    Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid
    Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid
    Screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
    tightening torque
    0.5 N.m
    overvoltage category
    III conforming to EN/IEC 60664-1
    net weight
    0.22 kg
    Environment
    immunity to microbreaks
    10 ms
    product certifications
    GOST
    C-Tick
    UL
    GL
    CSA
    standards
    EN/IEC 60068-2-27 Ea
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-12
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-5
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-11
    EN/IEC 61000-4-3
    EN/IEC 61000-4-6 level 3
    IP degree of protection
    IP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    environmental characteristic
    EMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    disturbance radiated/conducted
    Class B conforming to EN 55022-11 group 1
    pollution degree
    2 conforming to EN/IEC 61131-2
    ambient air temperature for operation
    -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    ambient air temperature for storage
    -40…70 °C
    operating altitude
    2000 m
    maximum altitude transport
    3048 m
    relative humidity
    95 % without condensation or dripping water
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Not applicable, out of EU RoHS legal scope
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • Documents

    Language
    • English
    • Spanish
    • Portuguese
    • French
    • Italian
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    Modules logiques Zelio Logic (Version 3.1)
    Date 7/20/18
    Size 5.6 MB
    Smart Relays - Zelio Logic (Version 3.1)
    Date 7/20/18
    Size 5.7 MB
    User guide
    Date
    Size
    Add to My Documents
    Zelio Logic - Module logique, Manuel utilisateur (Version 01)
    Zelio Logic, Programmierhandbuch (Version 01)
    Zelio Logic, Guía de programación (Version 01)
    Zelio Logic - Módulo lógico, Manual do usuário (Version 01)
    Zelio Logic, Manual de programação (Version 01)
    Zelio Logic - Módulo lógico, Manual del usuario (Version 01)
    Zelio Logic - Modulo logico, Manuale utente (Version 01)
    Zelio Logic, Guide de programmation (Version 01)
    Zelio Logic - Logikmodul, Benutzerhandbuch (Version 01)
    Zelio Logic, Guida di programmazione (Version 01)
    Zelio Soft 2, Guía de ejemplos de aplicaciones (Version 00)
    Zelio Soft 2, Guia de exemplos do aplicativo (Version 00)
    Zelio Soft 2, Applikationen - Handbuch der Beispiele (Version 00)
    Zelio Soft 2, Exemples d''applications (Version 00)
    Zelio Soft 2, Guida degli esempi delle applicazioni (Version 00)
    Zelio Logic Programming Guide (Version 01)
    Date 10/1/17
    Size 4.6 MB
    Zelio Logic - Smart Relay, User Manual (Version 01)
    Zelio Soft 2, Applications Examples Guide (Version 00)
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for SR2D101FU: compact smart relay Zelio Logic - 10 I O - 100..240 V AC - no clock - no display (Version 2.0)
    Certificate
    Date
    Size
    Add to My Documents
    RCM_SR2_SR3_Zelio_Relay (Version 1.0)
    Date 6/28/17
    Size 149.1 KB
    Instruction sheet
    Date
    Size
    Add to My Documents
    SR2D... /SR2E... Logic compact module Zelio (Version 04)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    EC_Declaration_SR2_SR3 (Version 1.2)
    Date 4/6/18
    Size 543.7 KB
    End of Life Information
    Date
    Size
    Add to My Documents
    Zelio Logic SR2 - SR3 Smart Relays, Product End-of-Life Instructions (Version 2.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Marine certificate
    Date
    Size
    Add to My Documents
    DNV-GL Marine Certificate Zelio SR2 SR3 Smart Relays (Version 3.0)
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Zelio Logic SR2 - SR3 Smart Relays, Product Environmental Profile (Version 3.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    RoHs China Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /