Range: Lexium SD3 & Motors

Stepper motor drives

SD328AU25S2

Schneider Electric SD328AU25S2 Image
Range: Lexium SD3 & Motors

Stepper motor drives

SD328AU25S2

motion control stepper motor drive - SD328 - <= 2.5 A

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Lexium SD3
    product or component type
    Motion stepper drive
    device short name
    SD328
    supply voltage limits
    100...120 V
    200...240 V
    bus type
    Fieldbus
    Complementary
    format of the drive
    Block
    network number of phases
    Single phase
    [Us] rated supply voltage
    100...120 V (- 15...10 %)
    200...230 V (- 15...10 %)
    supply voltage type
    AC/DC
    network frequency limits
    50...60 Hz (- 15...10 %)
    communication interface
    Integrated CANopen
    Integrated analogue input
    Integrated Modbus
    motor phase current
    <= 2.5 A
    current consumption
    <= 0.2 mA (24 V control voltage)
    3 A at 230 V (main supply)
    4 A at 115 V (main supply)
    nominal power
    180 W at 115 V
    270 W at 230 V
    short-circuit current
    0.5 kA
    power losses
    <= 26 W
    associated fuse rating
    6 A at 115 V
    6 A at 230 V
    overvoltage category
    III
    inrush current
    < 60 A
    leakage current
    < 30 mA 10 m conforming to IEC 60990-3
    voltage state 0 guaranteed
    -3...5 V (24 V input signals)
    voltage state 1 guaranteed
    15...30 V (24 V input signals)
    input current
    <= 10 mA (24 V input signals)
    input frequency
    <= 200 kHz, signal input ENC_A, ENC_B, ENC_I, pulse/direction
    <= 400 kHz, signal input ENC_A, ENC_B, ENC_I, A/B
    output frequency
    < 400 kHz, pulse/direction interface, A/B
    <= 200 kHz, pulse/direction interface, pulse/direction
    maximum switching current
    <= 50 mA (24 V output signals)
    voltage drop
    1 V, 50 mA load (24 V output signals)
    physical interface
    2-wire RS 485 Modbus :
    RS422 - pulse/direction interface
    RS422 - signal input ENC_A, ENC_B, ENC_I
    output voltage
    <= 30 V (24 V output signals)
    4.75...5.25 V (ENC+5V_OUT signal output)
    input voltage
    24 V -15 %/+20 % (24 V control voltage)
    -10...10 V (analogue input signals)
    residual ripple
    < 5 % (24 V control voltage)
    resistance
    10 kOhm (analogue input signals)
    5 kOhm (pulse/direction interface)
    analogue input type
    Voltage - 10...10 V, resolution: 14 bits, duration: 0.25 ms
    electrical connection
    Connector RJ45 for CANopen interface)
    Connector RJ45 for Modbus interface)
    Spring terminal for CANopen interface)
    mode of transmission
    RTU (Modbus)
    method of access
    Slave (CANopen)
    transmission rate
    125 kbps, 250 kbps, 500 kbps, 1 Mbps (CANopen)
    9600, 19200, 38400 bps (Modbus)
    number of addresses
    1...127 (CANopen)
    1...247 (Modbus)
    installed device
    127 stepper motor drives for CANopen
    31 stepper motor drives for Modbus
    data format
    8 bits, 1 stop, even parity for Modbus
    8 bits, no parity, 1 stop for Modbus
    8 bits, no parity, 2 stop for Modbus
    8 bits, odd parity, 1 stop for Modbus
    communication service
    1 PDO configurable for CANopen
    2 SDOs receive for CANopen
    2 SDOs send for CANopen
    3 PDOs as per DSP 402 for CANopen
    CiA DSP 402 profile for CANopen
    Diagnostics (08) for Modbus
    Emergency for CANopen
    Note guarding, heartbeat for CANopen
    Read device identification (43) for Modbus
    Read hold register (03), maximum 63 words for Modbus
    Read/write multiple registers (23), maximum 63/59 words for Modbus
    Write multiple registers (16), maximum 61 words for Modbus
    Write single register (06) for Modbus
    local signalling
    1 LED - ERR for CANopen
    1 LED - RUN for CANopen
    safety function
    Safe torque off safety function for machine conforming to IEC/EN 61800-5-2
    Safe torque off safety function for machine conforming to ISO 13849-1 level d
    Safe torque off safety function for system process conforming to EN/IEC 61508 level SIL2
    Safe torque off safety function for system process conforming to IEC/EN 61800-5-2
    type of cooling
    Natural convection
    maximum mechanical speed
    3000 rpm
    height
    145 mm
    width
    72 mm
    depth
    140 mm
    shock resistance
    15 gn for 11 ms conforming to EN/IEC 60068-2-27
    product weight
    1.1 kg
    Environment
    electromagnetic compatibility
    Electrostatic discharge level 3 conforming to EN/IEC 61000-4-2
    Immunity to electrical transients level 4 conforming to EN/IEC 61000-4-4
    Immunity to radiated radio-electrical interference level 3 conforming to EN/IEC 61000-4-3
    Voltage/current impulse level 3 conforming to EN/IEC 61000-4-5
    standards
    EN/IEC 50178
    EN/IEC 61800-3
    EN/IEC 61800-3 environment 1
    EN/IEC 61800-3 environment 2
    EN/IEC 61800-5-1
    product certifications
    CUL
    TÜV
    UL
    marking
    CE
    ambient air temperature for operation
    0...50 °C
    ambient air temperature for storage
    -25...70 °C
    pollution degree
    Level 2
    relative humidity
    5...85 % without condensation
    operating altitude
    <= 1000 m without derating
    > 1000...< 2000 m without derating (maximum ambient temperature 40°C, no protective film, lateral distance of > 50mm)
    vibration resistance
    1.5 mm (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
    1 gn (f = 13...150 Hz) conforming to EN/IEC 60068-2-6
    IP degree of protection
    IP20
    IP40 on upper part without removal of protective film
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • German
    CAD
    Date
    Size
    Add to My Documents
    Date 12/13/11
    Size 466.8 KB
    Certificate
    Date
    Size
    Add to My Documents
    Date 8/21/18
    Size 746 KB
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 8/21/18
    Size 137.5 KB
    Product environmental
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    EMC mounting plate (included)



  • Mounting and Clearance

    Mounting and Clearance


    Ambient temperature

    Mounting distances

    Mounting recommendations

    Without protective film (1)

    With protective film

    0 ... +40 °C

    d > 50 mm/1.97 in.

    None

    None

    d > 50 mm/1.97 in.

    None

    d > 10 mm/0.39 in.

    +40 ... +50 °C

    d > 50 mm/1.97 in.

    None

    Reduce nominal and continuous current by 2.2 % per °C above 40 °C

    d > 50 mm/1.97 in.

    Reduce nominal and continuous current

    Operation not possible

    (1) Recommendation: remove protective film after installation.


  • Connections and Schema

    SD328A Connection Example with Local Control



    SD328A Connection Example with Fieldbus Control



    Example of Application of the Safety Function: Category 0 Stop



    Example of Application of the Safety Function: Category 1 Stop