Characteristics
Main range of product Zelio Analogproduct or component type Voltage/current converteranalogue input type Current 0...1.5 A AC/DC 50/60 HzCurrent 0...15 A AC/DC 50/60 HzCurrent 0...5 A AC/DC 50/60 Hzanalogue output type Current 0...20 mA <= 500 Ohm by cablingCurrent 4...20 mA <= 500 Ohm by cablingVoltage 0...10 V >= 100 kOhm by cablingComplementary protection type Overvoltage protection on output (+/- 30 V)Reverse polarity protection on outputShort-circuit protection on outputabnormal analogue output voltage -15...0 V, when no input or input wire brokenabnormal analogue output current 0...-30 mA, output selected 0...20 mA, when no input or input wire broken4...-30 mA, output selected 4...20 mA, when no input or input wire broken[Us] rated supply voltage 24 V DC +/- 20 %, isolatedcurrent consumption <= 70 mA for voltage output<= 90 mA for current outputlocal signalling LED green (power ON)measurement error +/- 5 % of full scale at 20 °C+/- 10 % of full scale at 20 °C (electromagnetic interference of 10 V/m)repeat accuracy +/- 0.2 % full scale at 20 °C+/- 0.6 % full scale at 60 °Ctemperature coefficient 1000 ppm/°C, range: 0...5 A2000 ppm/°C, range: 0...15 A500 ppm/°C, range: 0...1.5 Aclamping connection capacity 1 x 2.5 mm²2 x 1.5 mm²tightening torque 0.6...1.1 N.mmarking CEsurge withstand 0.5 kV for 1.2/50 µs conforming to IEC 61000-4-5[Ui] rated insulation voltage 2 kVfixing mode By screws, mounting plateClip-on, 35 mm symmetrical DIN railsafety reliability data MTTFd = 23.9 yearsB10d = 22108product weight 0.15 kgEnvironment standards IEC 60584-1IEC 60947-1product certifications CSAGLULIP degree of protection IP20 terminal blockIP50 housingfire resistance 850 °C conforming to IEC 60695-2-1850 °C conforming to ULshock resistance 50 gn for 11 ms conforming to IEC 60068-2-27vibration resistance 5 gn (f = 10...100 Hz) conforming to IEC 60068-2-6resistance to electrostatic discharge 6 kV (in contact) conforming to IEC 61000-4-2 level 38 kV (in air) conforming to IEC 61000-4-2 level 3resistance to fast transients 1 kV on input-output conforming to IEC 61000-4-42 kV on power supply conforming to IEC 61000-4-4disturbance radiated/conducted CISPR 11CISPR 22 group 1 - class Bambient air temperature for storage -40...85 °Cambient air temperature for operation 0...50 °C (mounting side by side)0...60 °C (2 cm spacing)pollution degree 2 conforming to IEC 60664-1Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- French
CatalogueSizeAdd to My DocumentsModules logiques Zelio Logic (Version 3.1)CADSizeAdd to My DocumentsCAD files for RMCA61BD: Zelio Control (Version 1.0)CertificateSizeAdd to My DocumentsCSA Certificate RMPT, RMT, RMC (Version 1.0)EAC Certificate RMC RMPT RMT (Version 1.0)Declaration of conformitySizeAdd to My DocumentsZelio Analog Converters-RMPT RMT RMC (Version 1.0)End of Life InformationSizeAdd to My DocumentsZelio Analog Interface, Product End of Life Instructions (Version 1.0)Product Environmental ProfileSizeAdd to My DocumentsZelio Analog Interface, Product Environmental Profile (Version 1.0) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Analog Interface: Voltage/Current ConverterDimensions(1)Terminal block AB1TP435U or AB1RRNTP435U2 -
Mounting and Clearance
MountingMounting on Rails AM1•••••Panel Mounting -
Connections and Schema
Analog Interface: Voltage/Current ConverterWiring Diagram(1)Use 1 input only.(2)Use 1 output only.The input, output and power supply lines must be kept away from the power cables to avoid effects due to induced interference.
The input and output cables must be shielded as indicated in the schemes and must be kept away from each other.