Global (English)

Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

Schneider Electric RM4JA01B Image

View all Zelio Control Relays

Zelio Control Relays - RM4JA01B

Legacy

Schneider Electric RM4JA01B Image
View all Zelio Control Relays
Zelio Control Relays - RM4JA01B
Legacy

current measurement relay RM4-J - range 3..1000 mA - 24 V

Show more characteristics >
Add to My Products Remove from My Products

RM4JA01B is replaced by:
Product
Qty
RM22JA21MR
Qty
1
Add to My Products Remove from My Products
  • Reason for Substitution: End of life
  • Substitution date: 05 July 2016
  • Main
    range of product
    Zelio Control
    product or component type
    Industrial measurement and control relays
    relay type
    Current measurement relay
    relay name
    RM4J
    relay monitored parameters
    Overcurrent detection
    time delay type
    Without
    power consumption in VA
    2 VA AC
    measurement range
    0.3...30 mA current AC 50/60 Hz
    0.3...30 mA current DC
    10...100 mA current AC 50/60 Hz
    10...100 mA current DC
    100...1000 mA current AC 50/60 Hz
    100...1000 mA current DC
    contacts type and composition
    1 C/O
    Complementary
    maximum switching voltage
    440 V AC
    [Us] rated supply voltage
    24 V AC, 50/60 Hz +/- 5 %
    control circuit voltage limits
    0.85...1.1 Uc
    output contacts
    1 C/O
    measuring cycle
    <= 80 ms
    internal input resistance
    1 Ohm
    10 Ohm
    33 Ohm
    permissible continuous overload
    0.05 A
    0.15 A
    1.5 A
    permissible non repetitive overload
    5 A
    0.2 A
    0.5 A
    setting accuracy of the switching threshold
    +/-5 %
    switching threshold drift
    <= 0.06 % per degree centigrade depending permissible ambient air temperature
    <= 0.5 % within the supply voltage range (0.85...1.1 Un)
    setting accuracy of time delay
    10 P
    hysteresis
    5...30 % adjustable of current threshold setting
    marking
    CE : EMC 89/336/EEC
    CE : LVD 73/23/EEC
    overvoltage category
    III conforming to IEC 60664-1
    [Ui] rated insulation voltage
    500 V conforming to IEC
    supply disconnection value
    > 0.1 Uc
    operating position
    Any position without derating
    connections - terminals
    Screw terminals 2 x 1.5 mm², flexible cable with cable end
    Screw terminals 2 x 2.5 mm², flexible cable without cable end
    tightening torque
    0.6...1.1 N.m
    mechanical durability
    30000000 cycles
    [Ith] conventional free air thermal current
    8 A
    [Ie] rated operational current
    2 A at 24 V DC-13 70 °C conforming to IEC 60947-5-1/1991
    2 A at 24 V DC-13 70 °C conforming to VDE 0660
    3 A at 115 V AC-15 70 °C conforming to IEC 60947-5-1/1991
    3 A at 115 V AC-15 70 °C conforming to VDE 0660
    3 A at 24 V AC-15 70 °C conforming to IEC 60947-5-1/1991
    3 A at 24 V AC-15 70 °C conforming to VDE 0660
    3 A at 250 V AC-15 70 °C conforming to IEC 60947-5-1/1991
    3 A at 250 V AC-15 70 °C conforming to VDE 0660
    0.1 A at 250 V DC-13 70 °C conforming to IEC 60947-5-1/1991
    0.1 A at 250 V DC-13 70 °C conforming to VDE 0660
    0.3 A at 115 V DC-13 70 °C conforming to IEC 60947-5-1/1991
    0.3 A at 115 V DC-13 70 °C conforming to VDE 0660
    switching capacity in mA
    10 mA at 12 V
    switching voltage
    250 V AC
    contacts material
    90/10 silver nickel contacts
    number of cables
    2
    width
    23 mm
    height
    78 mm
    depth
    80 mm
    terminals description ISO n°1
    (15-16-18)OC
    (A1-A2)CO
    (C-B1-B2-B3)CO
    output relay state
    Tripped if A measured > A set
    Tripped if V measured > V set
    9 mm pitches
    2.5
    product weight
    0.172 kg
    Environment
    electromagnetic compatibility
    Electrostatic discharge - test level 6 kV, level 3 - contact discharge conforming to IEC 61000-4-2
    Electrostatic discharge - test level 8 kV, level 3 - air discharge conforming to IEC 61000-4-2
    standards
    EN/IEC 60255-6
    product certifications
    CSA
    GL
    UL
    ambient air temperature for storage
    -40...85 °C
    ambient air temperature for operation
    -20...65 °C
    environmental characteristic
    3K3
    relative humidity
    15...85 % conforming to IEC 60721-3-3
    shock resistance
    15 gn for 11 ms conforming to IEC 60255-21-1
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP50 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2.5 kV
    non-dissipating shock wave
    4.8 kV
    resistance to electrostatic discharge
    6 kV contact conforming to IEC 61000-4-2 level 3
    8 kV air conforming to IEC 61000-4-2 level 3
    resistance to electromagnetic fields
    10 V/m conforming to IEC 61000-4-3 level 3
    resistance to fast transients
    2 kV conforming to IEC 61000-4-4 level 3
    protection against electric shocks
    2 kV : level 3 conforming to IEC 61000-4-5
    disturbance radiated/conducted
    CISPR 11 group 1 - class A
    CISPR 22 - class A
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    End of life manual
    Date
    Size
    Add to My Documents
    Product environmental
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Current Measurement Relays
    Dimensions



  • Mounting and Clearance

    Current Measurement Relays
    Rail mounting


    Screw fixing



  • Connections and Schema

    Current Measurement Relays
    RM4JA01 Wiring Diagram


    A1-A2
    Supply voltage
    B1, B2, B3, C
    Currents to be measured (see table below)

    Connection and current values to be measured

    B1-C

    3…30 mA

    B2-C

    10…100 mA

    B3-C

    0.1…1 A

    RM4JA31 Wiring Diagram


    A1-A2
    Supply voltage
    B1, B2, B3, C
    Currents to be measured (see table below)

    Connection and current values to be measured

    B1-C

    3…30 mA

    B2-C

    10…100 mA

    B3-C

    0.1…1 A

    RM4JA32 Wiring Diagram


    A1-A2
    Supply voltage
    B1, B2, B3, C
    Currents to be measured (see table below)

    Connection and current values to be measured

    B1-C

    0.3…1.5 A

    B2-C

    1…5 A

    B3-C

    3…15 A


  • Performance Curves

    Electrical Durability and Load Limit Curves
    AC Load

    Curve 1: Electrical durability of contacts on resistive load in millions of operating cycles


    X
    Current broken in A
    Y
    Millions of operating cycles

    Curve 2: Reduction factor k for inductive loads (applies to values taken from durability Curve 1)


    X
    Power factor on breaking (cos φ)
    Y
    Reduction factor K

    DC Load

    Load limit curve


    X
    Current in A
    Y
    Voltage in V
    1
    L/R = 20 ms
    2
    L/R with load protection diode
    3
    Resistive load



  • Technical Description

    Function Diagram
    Overcurrent Detection

    Function “>”


    Legend

    t Time delay

    U A1-A2 Supply voltage

    IS1 Setting current threshold

    IS2 Current measured

    15-18, 15-16; 25-28, 25-26 Output relays connections

    Relay status: black color = energized.