voltage control relay RM35-U - range 194..528 V AC

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Zelio Control
    product or component type
    Modular measurement and control relays
    relay type
    Voltage control relay
    product specific application
    For 3-phase supply
    relay name
    RM35UB3
    relay monitored parameters
    Overvoltage and undervoltage between phases
    time delay type
    Adjustable 0.3...30 s, 0 + 10 % on crossing the threshold
    switching capacity in VA
    1250 VA
    minimum switching current
    10 mA at 5 V DC
    maximum switching current
    5 A AC/DC
    power consumption in VA
    0...22 VA at 400 V AC 50 Hz
    measurement range
    194...528 V voltage AC 50/60 Hz
    utilisation category
    AC-12 conforming to IEC 60947-5-1
    AC-13 conforming to IEC 60947-5-1
    AC-14 conforming to IEC 60947-5-1
    AC-15 conforming to IEC 60947-5-1
    DC-12 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    DC-14 conforming to IEC 60947-5-1
    Complementary
    reset time
    1500 ms for time delay
    maximum switching voltage
    250 V AC/DC
    [Us] rated supply voltage
    220...480 V AC, 50/60 Hz +/- 10 %
    supply voltage limits
    194...528 V AC
    voltage detection threshold
    194 V
    control circuit frequency
    50...60 Hz +/- 15 %
    output contacts
    1 C/O + 1 C/O, 1 per threshold
    nominal output current
    5 A
    measuring cycle
    <= 150 ms measurement cycle as true rms value
    hysteresis
    2 %
    run-up delay at power-up
    <= 650 ms
    measurement accuracy
    +/- 10 % of the full scale value
    repeat accuracy
    +/- 0.5 % for input and measurement circuit
    +/- 1 % for time delay
    measurement error
    < 1 % over the whole range with voltage variation
    0.05 %/°C with temperature variation
    response time
    < 200 ms in the event of a fault
    quality labels
    CE
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 500 MOhm at 500 V DC conforming to IEC 60255-5
    > 500 MOhm at 500 V DC conforming to IEC 60664-1
    [Ui] rated insulation voltage
    400 V conforming to IEC 60664-1
    operating position
    Any position without derating
    connections - terminals
    Screw terminals 1 x 0.5...1 x 4 mm² - AWG 20...AWG 11, solid cable without cable end
    Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable end
    Screw terminals 2 x 0.2...2 x 1.5 mm² - AWG 24...AWG 16, flexible cable with cable end
    Screw terminals 1 x 0.2...2 x 2.5 mm² - AWG 24...AWG 12, flexible cable with cable end
    tightening torque
    0.6...1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    local signalling
    LED green for power ON
    LED yellow for relay ON
    mounting support
    35 mm symmetrical DIN rail conforming to EN/IEC 60715
    electrical durability
    10000 cycles
    mechanical durability
    <= 30000000 cycles
    operating rate
    <= 360 operations/hour under full load
    safety reliability data
    B10d = 300000
    MTTFd = 319.6 years
    width
    35 mm
    product weight
    0.08 kg
    Environment
    electromagnetic compatibility
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
    standards
    EN/IEC 60255-1
    product certifications
    CSA
    C-Tick
    GL
    GOST
    UL
    directives
    89/336/EEC - electromagnetic compatibility
    73/23/EEC - low voltage directive
    ambient air temperature for storage
    -40...70 °C
    ambient air temperature for operation
    -20...50 °C
    relative humidity
    95 % at 55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6
    1 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1
    shock resistance
    5 gn conforming to IEC 60068-2-27
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP30 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2 kV AC 50 Hz, 1 min
    non-dissipating shock wave
    4 kV
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • French
    • Italian
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    Date 1/9/18
    Size 8.4 MB
    Date 1/9/18
    Size 8.4 MB
    Certificate
    Date
    Size
    Add to My Documents
    Date 6/25/18
    Size 5.8 MB
    Date 8/6/18
    Size 1 MB
    UL Listed RM17, RM22, RM35, RM8487
    Date 8/2/18
    Size 213 B
    Instruction sheet
    Date
    Size
    Add to My Documents
    End of life manual
    Date
    Size
    Add to My Documents
    Product environmental
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    3-Phase Voltage Control Relays
    Dimensions and Mounting



  • Connections and Schema

    3-Phase Voltage Control Relays
    Wiring Diagram



  • Technical Description

    Function Diagrams
    Phase Failure Detection (U measured < 0.7 x nominal supply voltage)


    Control of Overvoltage and Undervoltage


    Legend

    Un Nominal supply voltage

    Tt1 Overvoltage threshold delay (adjustable on front panel from 0.3 s to 30 s)

    Tt2 Undervoltage threshold delay (adjustable on front panel 0.3 s to 30 s)

    H Hysteresis

    U> Overvoltage threshold

    U< Undervoltage threshold

    L1, L2, L3 Phases of the supply voltage monitored

    11-12, 11-14 R1 output relay connections (refer to Connections and Schema)

    21-22, 21-24 R2 output relay connections (refer to Connections and Schema)

    Relay status: black color = energized.