multifunction voltage control relay RM35-U - range 15..600 V

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Zelio Control
    product or component type
    Modular measurement and control relays
    relay type
    Multifunction voltage control relay
    relay name
    RM35UA
    relay monitored parameters
    Overvoltage or undervoltage detection
    time delay type
    Adjustable 0.3...30 s, 0 + 10 % on crossing the threshold
    switching capacity in VA
    1250 VA
    minimum switching current
    10 mA at 5 V DC
    maximum switching current
    5 A AC/DC
    power consumption in VA
    0...3.5 VA AC
    measurement range
    15...600 V voltage
    utilisation category
    AC-12 conforming to IEC 60947-5-1
    AC-13 conforming to IEC 60947-5-1
    AC-14 conforming to IEC 60947-5-1
    AC-15 conforming to IEC 60947-5-1
    DC-12 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    DC-14 conforming to IEC 60947-5-1
    Complementary
    reset time
    1500 ms for time delay
    maximum switching voltage
    250 V AC/DC
    [Us] rated supply voltage
    24...240 V AC/DC, 50/60 Hz +/- 10 %
    supply voltage limits
    20.4...264 V AC/DC
    power consumption in W
    <= 0.6 W DC
    immunity to microbreaks
    10 ms
    control circuit frequency
    40...70 Hz +/- 10 %
    resistance across terminals
    150 mOhm E1-M terminals
    300 mOhm E2-M terminals
    600 mOhm E3-M terminals
    output contacts
    2 C/O
    nominal output current
    5 A
    measuring cycle
    <= 30 ms measurement cycle as true rms value
    hysteresis
    5...50 % of threshold setting
    run-up delay at power-up
    <= 600 ms
    measurement accuracy
    +/- 10 % of the full scale value
    repeat accuracy
    +/- 0.5 % for input and measurement circuit
    +/- 2 % for time delay
    measurement error
    +/- 0.05 %/°C with temperature variation
    < 1 % over the whole range with voltage variation
    polarity
    Non reversible polarity on DC supply
    sensitivity scale
    15...150 V E1-M terminals
    30...300 V E2-M terminals
    60...600 V E3-M terminals
    threshold setting
    10...100 %
    quality labels
    CE
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5
    > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1
    > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5
    > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1
    > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5
    > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1
    [Ui] rated insulation voltage
    250 V conforming to IEC 60664-1
    600 V conforming to IEC 60664-1
    control circuit voltage limits
    - 15 % + 10 % Un
    operating position
    Any position without derating
    connections - terminals
    Screw terminals 1 x 0.5...1 x 4 mm² - AWG 20...AWG 11, solid cable without cable end
    Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable end
    Screw terminals 2 x 0.2...2 x 1.5 mm² - AWG 24...AWG 16, flexible cable with cable end
    Screw terminals 1 x 0.2...2 x 2.5 mm² - AWG 24...AWG 12, flexible cable with cable end
    tightening torque
    0.6...1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    local signalling
    LED green for power ON
    LED yellow for relay ON
    mounting support
    35 mm symmetrical DIN rail conforming to EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    <= 30000000 cycles
    operating rate
    <= 360 operations/hour under full load
    safety reliability data
    MTTFd = 308.2 years
    B10d = 290000
    width
    35 mm
    product weight
    0.08 kg
    Environment
    electromagnetic compatibility
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
    standards
    EN/IEC 60255-6
    product certifications
    CSA
    C-Tick
    GL
    GOST
    UL
    directives
    89/336/EEC - electromagnetic compatibility
    73/23/EEC - low voltage directive
    ambient air temperature for storage
    -40...70 °C
    ambient air temperature for operation
    -20...50 °C
    relative humidity
    95 % at 55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6
    1 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1
    shock resistance
    5 gn conforming to IEC 60068-2-27
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP30 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2 kV AC 50 Hz, 1 min conforming to IEC 60255-5
    2 kV AC 50 Hz, 1 min conforming to IEC 60664-1
    non-dissipating shock wave
    4 kV conforming to IEC 60255-5
    4 kV conforming to IEC 60664-1
    4 kV conforming to IEC 61000-4-5
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • French
    • Italian
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    Date 1/9/18
    Size 8.4 MB
    Date 1/9/18
    Size 8.4 MB
    Certificate
    Date
    Size
    Add to My Documents
    Date 6/25/18
    Size 5.8 MB
    Date 8/6/18
    Size 1 MB
    UL Listed RM17, RM22, RM35, RM8487
    Date 8/2/18
    Size 213 B
    Instruction sheet
    Date
    Size
    Add to My Documents
    Date 12/13/17
    Size 378.8 KB
    Date 12/14/17
    Size 3.2 MB
    End of life manual
    Date
    Size
    Add to My Documents
    Product environmental
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Multifunction Voltage Control Relays
    Dimensions and Mounting



  • Connections and Schema

    Multifunction Voltage Control Relays
    Wiring Diagram



  • Technical Description

    Function Diagrams
    Undervoltage Control

    Without memory ("No Memory" mode)


    With memory ("Memory" mode)


    Overvoltage Control

    Without memory ("No Memory" mode)


    With memory ("Memory" mode)


    Legend

    Tt Time delay after crossing of threshold

    Un Nominal supply voltage

    U Monitored supply voltage

    H Hysteresis

    U> Overvoltage threshold

    U< Undervoltage threshold

    11-12/11-14, 21-22/21-24 Output relay connections

    Relay status: black color = energized.

    NOTE: In "Memory" mode, the relay opens when crossing of the threshold is detected and then stays in that position. The power supply voltage must be switched off to reset the product.