Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

multifunction phase control relay RM35-T - range 194..528 V AC

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Control
    product or component type
    Modular measurement and control relays
    relay type
    Multifunction control relay
    product specific application
    For 3-phase supply
    relay name
    RM35TF
    relay monitored parameters
    Phase failure detection
    Undervoltage and overvoltage in window mode
    Asymmetry
    Phase sequence
    time delay
    Adjustable 0.1...10 s, +/- 10 % of the full scale value
    switching capacity in VA
    1250 VA
    measurement range
    208...480 V voltage AC
    Complementary
    reset time
    <= 1500 ms for at 480 V
    maximum switching voltage
    250 V AC
    250 V DC
    minimum switching current
    10 mA at 5 V DC
    maximum switching current
    5 A AC
    5 A DC
    supply voltage limits
    194...528 V AC, 3 phases
    control circuit voltage limits
    - 12 % + 10 % Un
    power consumption in VA
    0...22 VA at 400 V AC 50 Hz
    voltage detection threshold
    < 194 V
    control circuit frequency
    50...60 Hz +/- 10 %
    output contacts
    2 C/O
    nominal output current
    5 A
    measurement voltage limits
    176...528 V AC
    hysteresis
    2 %
    delay at power up
    <= 650 ms
    measuring cycle
    <= 140 ms measurement cycle as true rms value
    threshold adjustment voltage
    +2...+10 % in the range 480 V AC
    -12...-2 % in the range 220 V AC
    2...20 % of Un selected
    -20...-2 % in the range 380...480 V AC
    +2...+20 % in the range 220...440 V AC
    voltage range
    220...480 V phase to phase
    adjustment of asymmetry threshold
    5...15 % of Un selected
    repeat accuracy
    0.3 % for time delay
    0.5 % for input and measurement circuit
    measurement error
    < 1 % over the whole range with voltage variation
    0.05 %/°C with temperature variation
    response time
    < 200 ms in the event of a fault
    marking
    CE
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 500 MOhm at 500 V DC conforming to IEC 60255-5
    > 500 MOhm at 500 V DC conforming to IEC 60664-1
    [Ui] rated insulation voltage
    400 V conforming to IEC 60664-1
    supply frequency
    50/60 Hz +/- 10 %
    operating position
    Any position without
    connections - terminals
    Screw terminals 1 x 0.5...1 x 4 mm² - AWG 20...AWG 11, solid cable without cable end
    Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable end
    Screw terminals 1 x 0.2...1 x 2.5 mm² - AWG 24...AWG 12, flexible cable with cable end
    Screw terminals 2 x 0.2...2 x 1.5 mm² - AWG 24...AWG 16, flexible cable with cable end
    tightening torque
    0.6...1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    local signalling
    LED green for power ON
    LED yellow for relay ON
    LED yellow for fault
    mounting support
    35 mm symmetrical DIN rail conforming to EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    <= 30000000 cycles
    operating rate
    <= 360 operations/hour under full load
    utilisation category
    AC-12 conforming to IEC 60947-5-1
    AC-13 conforming to IEC 60947-5-1
    AC-14 conforming to IEC 60947-5-1
    AC-15 conforming to IEC 60947-5-1
    DC-12 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    safety reliability data
    MTTFd = 399.5 years
    B10d = 360000
    width
    35 mm
    product weight
    0.13 kg
    Environment
    electromagnetic compatibility
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to EN/IEC 61000-6-2
    standards
    EN/IEC 60255-1
    product certifications
    UL
    C-Tick
    GOST
    CSA
    GL
    directives
    89/336/EEC - electromagnetic compatibility
    73/23/EEC - low voltage directive
    ambient air temperature for storage
    -40...70 °C
    ambient air temperature for operation
    -20...50 °C
    relative humidity
    95 % at 55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6
    1 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1
    shock resistance
    15 gn for 11 ms conforming to IEC 60255-21-1
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP30 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2 kV 1 min AC 50 Hz
    non-dissipating shock wave
    4 kV
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  0701  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • French
    • Italian
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    Zelio Control - Monitoring & Control Relays catalog (Version 3.0)
    Catalogue Relais de mesure et de contrôle - Zelio Control (Version 3.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for RM35TF30: multifunction phase control relay RM35-T - range 194..528 V AC (Version 2.0)
    CAD for RM35TF30: multifunction phase control relay RM35-T - range 194..528 V AC (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    EAC Certificate RM4 RM17 RM22 RM35 (Version 1.0)
    CSA Certificate RM17, RM22, RM35, RM8487 (Version 1.0)
    UL Listed RM17, RM22, RM35, RM8487 (Version 1.0)
    Zelio Control RM35 CCC Certificate 2011010303495614 (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    RM17 UB..., RM35 UB/TF 3-phase voltage control, Instruction Sheet (Version 03)
    RM17UB310/ RM35UB3... / RM35TF30 3-phase voltage control Relay (Version 02)
    End of Life Information
    Date
    Size
    Add to My Documents
    RM... Control Relay, Product End-of-Life Instructions (Version 2.0)
    RM35... Measurement and Control Relay, Product End-of-Life Instructions (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 7/10/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    RM... Control Relay, Product Environmental Profile (Version 2.0)
    RM35... Measurement Relay, Product Environmental profile (Version 1.0)
    RM35... Measurement and Control Relay, Product Environmental profile (Version 1.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 7/10/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.