Characteristics
Main range of product Zelio Controlproduct or component type Modular measurement and control relaysrelay type Current control relayrelay name RM35JArelay monitored parameters Overcurrent or undercurrent detectionOvercurrent or undercurrent in window modetime delay Adjustable 1...20 s, 0 + 10 % on energisation TiAdjustable 0.3...30 s, 0 + 10 % on crossing the threshold Ttswitching capacity in VA 1250 VAminimum switching current 10 mA at 5 V DCmaximum switching current 5 A ACpower consumption in VA 3.5 VA ACmeasurement range 10...100 mA E2-M terminals2...20 mA E1-M terminals2...500 mA current50...500 mA E3-M terminalsutilisation category AC-12 conforming to IEC 60947-5-1AC-13 conforming to IEC 60947-5-1AC-14 conforming to IEC 60947-5-1AC-15 conforming to IEC 60947-5-1DC-12 conforming to IEC 60947-5-1DC-13 conforming to IEC 60947-5-1DC-14 conforming to IEC 60947-5-1Complementary reset time 1500 ms for time delaymaximum switching voltage 250 V AC[Us] rated supply voltage 24...240 V AC/DC, 50/60 Hz +/- 10 %supply voltage limits 20.4...264 V AC/DCoperating voltage tolerance - 15 % + 10 % Unpower consumption in W <= 0.6 W DCcontrol circuit frequency 40...70 Hz +/- 10 %resistance across terminals 1 Ohm E2-M terminals5 Ohm E1-M terminals0.2 Ohm E3-M terminalsoutput contacts 2 C/Onominal output current 5 Ameasuring cycle <= 30 ms measurement cycle as true rms valuehysteresis 5...50 % of threshold settingdelay at power up 0.3 smeasurement accuracy +/- 10 % of the full scale valuerepeat accuracy +/- 0.5 % for input and measurement circuit+/- 2 % for time delaymeasurement error 0.05 %/°C with temperature variation1 by volt over the whole range with voltage variationpolarity No DCthreshold setting 10...100 %marking CE : 73/23/EECCE : EMC 89/336/EECovervoltage category III conforming to IEC 60664-1insulation resistance > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5> 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1> 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1> 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5> 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1[Ui] rated insulation voltage 250 V conforming to IEC 60664-1operating position Any position without deratingconnections - terminals Screw terminals 1 x 0.5...1 x 4 mm² - AWG 20...AWG 11, solid cable without cable endScrew terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable endScrew terminals 1 x 0.2...1 x 2.5 mm² - AWG 24...AWG 12, flexible cable with cable endScrew terminals 2 x 0.2...2 x 1.5 mm² - AWG 24...AWG 16, flexible cable with cable endtightening torque 0.6...1 N.m conforming to IEC 60947-1housing material Self-extinguishing plasticlocal signalling LED green for power ONLED yellow for relay ONmounting support 35 mm symmetrical DIN rail conforming to EN/IEC 60715electrical durability 100000 cyclesmechanical durability 30000000 cyclesoperating rate <= 360 operations/hour under full loadsafety reliability data MTTFd = 296.8 yearsB10d = 270000contacts material Cadmium freewidth 35 mmproduct weight 0.13 kgEnvironment immunity to microbreaks 50 mselectromagnetic compatibility Emission standard for industrial environments conforming to EN/IEC 61000-6-4Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3Immunity for industrial environments conforming to NF EN/IEC 61000-6-2standards EN/IEC 60255-6product certifications CSAC-TickGLGOSTULambient air temperature for storage -40...70 °Cambient air temperature for operation -20...50 °Crelative humidity 95 % at 55 °C conforming to IEC 60068-2-30vibration resistance 0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-61 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1shock resistance 15 gn for 11 ms conforming to IEC 60255-21-1IP degree of protection IP20 (terminals) conforming to IEC 60529IP30 (casing) conforming to IEC 60529pollution degree 3 conforming to IEC 60664-1dielectric test voltage 2 kV AC 50 Hz, 1 min conforming to IEC 60255-52 kV AC 50 Hz, 1 min conforming to IEC 60664-1non-dissipating shock wave 4 kV conforming to IEC 60255-54 kV conforming to IEC 60664-14 kV conforming to IEC 61000-4-5Offer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- Danish
- French
- Finnish
- Chinese
- Dutch
- Norwegian
- Turkish
- Portuguese
- Russian
- Czech
- Polish
- Italian
- German
- Swedish
CatalogueSizeAdd to My DocumentsZelio Control - Monitoring & Control Relays catalog (Version 2.0)Catalogue Relais de mesure et de contrôle - Zelio Control (Version 2.0)CADSizeAdd to My DocumentsCAD files for RM35JA31MW: Zelio Control (Version 1.0)CertificateSizeAdd to My DocumentsZelio Control RM35 CCC Certificate 2011010303495614 (Version 1.0)EAC Certificate RM4 RM17 RM22 RM35 (Version 1.0)UL Listed RM17, RM22, RM35, RM8487 (Version 1.0)CSA Certificate RM17, RM22, RM35, RM8487 (Version 1.0)Instruction sheetSizeAdd to My DocumentsRM35 JA... Current control, 2...500 mA, 0,15...15 A (Version 02)End of Life InformationSizeAdd to My DocumentsRM35... Measurement and Control Relay, Product End-of-Life Instructions (Version 1.0)Date 2/17/16Size 89.6 KBProduct Environmental ProfileSizeAdd to My DocumentsRM35... Measurement and Control Relay, Product Environmental profile (Version 1.0)RM35... Measurement Relay, Product Environmental profile (Version 1.0)REACh DeclarationSizeAdd to My DocumentsEU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Current Control RelaysDimensions and Mounting -
Connections and Schema
Current Control RelaysWiring DiagramApplication SchemesExample: Detection of Jamming on a Crusher (Overcurrent Function)Current measured ≤ 15 A
Current measured > 15 A
-
Technical Description
Function DiagramsUndercurrent DetectionWithout memory ("No Memory" mode)
With memory ("Memory" mode)
Overcurrent DetectionWithout memory ("No Memory" mode)
With memory ("Memory" mode)
LegendTi Starting inhibition time delay
Tt Time delay after crossing of threshold
Un Supply voltage
I Monitored current
H Hysteresis
I> Overcurrent threshold
I< Undercurrent threshold
11-12/11-14, 21-22/21-24 Output relay connections
Relay status: black color = energized.