Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Choose your country or region

three-Phase Voltage control relay 200…240Vac, 2 C/O

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Control
    product or component type
    Modular measurement and control relays
    relay type
    Control relay
    network number of phases
    3 phases
    relay name
    RM22TR
    relay monitored parameters
    Overvoltage and undervoltage detection
    Phase failure detection
    Phase sequence
    time delay type
    Adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
    switching capacity in VA
    2000 VA
    measurement range
    200...240 V voltage AC
    Complementary
    reset time
    <= 1500 ms at maximum voltage
    maximum switching voltage
    250 V AC
    minimum switching current
    10 mA at 5 V DC
    maximum switching current
    8 A AC
    [Us] rated supply voltage
    200...240 V AC
    supply voltage limits
    160...288 V AC
    operating limits
    - 20 % + 20 % Un
    power consumption in VA
    10 VA at 240 V AC 60 Hz
    voltage detection threshold
    < 100 V AC
    supply voltage frequency
    50...60 Hz +/- 10 %
    output contacts
    2 C/O
    setting accuracy of the switching threshold
    +/- 10 % of the full scale
    switching threshold drift
    <= 0.05 % per degree centigrade depending permissible ambient air temperature
    <= 1 % within the supply voltage range
    setting accuracy of time delay
    10 P
    time delay drift
    <= 0.05 % per degree centigrade depending permissible ambient air temperature
    <= 1 % within the supply voltage range
    hysteresis
    2 % fixed of selectable
    run-up delay at power-up
    <= 650 ms
    measuring cycle
    150 ms measurement cycle as true rms value
    threshold adjustment voltage
    2...20 % of Un selected
    voltage range
    200...240 V phase to phase
    repeat accuracy
    +/- 0.5 % input and measurement circuit
    +/- 3 % time delay
    measurement error
    < 0.05 %/°C with temperature variation
    < 1 % over the whole range with voltage variation
    response time
    <= 300 ms
    overvoltage category
    III conforming to UL 508
    III conforming to IEC 60664-1
    insulation resistance
    > 100 MOhm at 500 V DC conforming to IEC 60255-27
    mounting position
    Any position
    connections - terminals
    Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable end
    Screw terminals 2 x 0.2...2 x 1.5 mm² - AWG 24...AWG 16, flexible cable with cable end
    Screw terminals 1 x 0.5...1 x 3.3 mm² - AWG 20...AWG 12, solid cable without cable end
    Screw terminals 1 x 0.2...1 x 2.5 mm² - AWG 24...AWG 14, flexible cable with cable end
    tightening torque
    0.6...1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    status LED
    LED yellow for relay ON
    LED green for power ON
    mounting support
    35 mm DIN rail conforming to EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    10000000 cycles
    utilisation category
    AC-1 conforming to IEC 60947-4-1
    DC-1 conforming to IEC 60947-4-1
    AC-15 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    safety reliability data
    B10d = 350000
    MTTFd = 388.1 years
    contacts material
    Cadmium free
    width
    22.5 mm
    product weight
    0.09 kg
    Environment
    immunity to microbreaks
    <= 10 ms
    electromagnetic compatibility
    Conducted and radiated emissions class B conforming to CISPR 22
    Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1
    Electrostatic discharge 6 kV level 3 contact discharge conforming to IEC 61000-4-2
    Electrostatic discharge 8 kV level 3 air discharge conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test 10 V/m level 3 conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test 4 kV level 4 direct conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test 2 kV level 4 capacitive coupling conforming to IEC 61000-4-4
    Surge immunity test 4 kV level 4 common mode conforming to IEC 61000-4-5
    Surge immunity test 2 kV level 4 differential mode conforming to IEC 61000-4-5
    Conducted and radiated emissions class B group 1 conforming to CISPR 11
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to EN/IEC 61000-6-2
    standards
    EN/IEC 60255-1
    product certifications
    China RoHS
    GL
    CCC
    CSA
    CE
    EAC
    UL
    RCM
    ambient air temperature for storage
    -40...70 °C
    ambient air temperature for operation
    -20...50 °C at 60 Hz
    -20...60 °C at 50 Hz AC/DC
    relative humidity
    93...97 % at 25...55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.075 mm (f = 10...58.1 Hz) (not in operation) conforming to IEC 60068-2-6
    1 gn (f = 10...58.1 Hz) (not in operation) conforming to IEC 60068-2-6
    0.035 mm (f = 58.1...150 Hz) (in operation) conforming to IEC 60068-2-6
    0.5 gn (f = 58.1...150 Hz) (in operation) conforming to IEC 60068-2-6
    shock resistance
    15 gn for 11 ms (not in operation) conforming to IEC 60068-2-27
    5 gn for 11 ms (in operation) conforming to IEC 60068-2-27
    IP degree of protection
    IP20 on terminals conforming to IEC 60529
    IP40 on housing conforming to IEC 60529
    IP50 on front panel conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    3 conforming to UL 508
    dielectric test voltage
    2.5 kV for 1 min AC 50 Hz conforming to IEC 60255-27
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  0701  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Product end of life instructions
  • Documents and Downloads

    Language
    • English
    • Spanish
    • French
    • Italian
    • Finnish
    • German
    • Chinese
    Catalogue
    Date
    Size
    Add to My Documents
    Zelio Control - Monitoring & Control Relays catalog (Version 3.0)
    Catalogue Relais de mesure et de contrôle - Zelio Control (Version 3.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD for RM22TR31: three-Phase Voltage control relay 200…240Vac, 2 C/O (Version 1.0)
    Brochure
    Date
    Size
    Add to My Documents
    Teollisuuden Tähtituotteet 2 (Version 1.0)
    Date 9/16/17
    Size 5.8 MB
    Certificate
    Date
    Size
    Add to My Documents
    EAC Certificate RM4 RM17 RM22 RM35 (Version 1.0)
    CSA Certificate RM17, RM22, RM35, RM8487 (Version 1.0)
    UL Listed RM17, RM22, RM35, RM8487 (Version 1.0)
    CCC Certificate RM22 RM35 (Version 1.0)
    Date 5/27/19
    Size 1.7 MB
    Instruction sheet
    Date
    Size
    Add to My Documents
    RM22... / RM35... Control Relays, Instruction Sheet (Version 04)
    End of Life Information
    Date
    Size
    Add to My Documents
    RM... Control Relay, Product End-of-Life Instructions (Version 2.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 7/10/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    RM... Control Relay, Product Environmental Profile (Version 2.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 7/10/19
    Size 195.3 KB
  • Technical FAQs

    No results found.