multifunction control relay RM17-TA - range 183..528 V AC

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Zelio Control
    product or component type
    Modular measurement and control relays
    relay type
    Multifunction control relay
    product specific application
    For 3-phase supply
    relay name
    RM17TA
    relay monitored parameters
    Asymmetry
    Phase failure detection
    Phase sequence
    time delay
    Adjustable 0.1...10 s, +/- 10 % of the full scale value
    switching capacity in VA
    1250 VA
    measurement range
    208...480 V voltage AC
    Complementary
    reset time
    1500 ms for time delay
    maximum switching voltage
    250 V AC
    250 V DC
    minimum switching current
    10 mA at 5 V DC
    maximum switching current
    5 A AC
    5 A DC
    supply voltage limits
    183...528 V AC
    control circuit voltage limits
    - 12 % + 10 % Un
    power consumption in VA
    0...22 VA at 400 V AC 50 Hz
    control circuit frequency
    50...60 Hz +/- 10 %
    output contacts
    1 C/O
    nominal output current
    5 A
    measurement voltage limits
    183...528 V AC
    hysteresis
    2 %
    delay at power up
    <= 650 ms
    measuring cycle
    <= 150 ms measurement cycle as true rms value
    threshold adjustment voltage
    +2...+17 % in the range 480 V AC
    -2...-12 % in the range 208 V AC
    -2...-17 % in the range 220 V AC
    2...20 % of Un selected
    voltage range
    208...480 V phase to phase
    adjustment of asymmetry threshold
    5...15 % of Un selected
    repeat accuracy
    0.5 % for input and measurement circuit
    3 % for time delay
    measurement error
    < 0.05 %/°C with temperature variation
    < 1 % over the whole range with voltage variation
    phase failure sensitivity
    0.7 Un
    response time
    < 200 ms in the event of a fault
    marking
    CE
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 500 MOhm at 500 V DC conforming to IEC 60255-5
    > 500 MOhm at 500 V DC conforming to IEC 60664-1
    [Ui] rated insulation voltage
    400 V conforming to IEC 60664-1
    supply frequency
    50/60 Hz +/- 10 %
    operating position
    Any position without
    connections - terminals
    Screw terminals 1 x 0.5...1 x 4 mm² - AWG 20...AWG 11, solid cable without cable end
    Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable end
    Screw terminals 1 x 0.2...1 x 2.5 mm² - AWG 24...AWG 12, flexible cable with cable end
    Screw terminals 2 x 0.2...2 x 1.5 mm² - AWG 24...AWG 16, flexible cable with cable end
    tightening torque
    0.6...1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    local signalling
    LED green for power ON
    LED yellow for relay ON
    mounting support
    35 mm symmetrical DIN rail conforming to EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    <= 30000000 cycles
    operating rate
    <= 360 operations/hour under full load
    utilisation category
    AC-12 conforming to IEC 60947-5-1
    AC-13 conforming to IEC 60947-5-1
    AC-14 conforming to IEC 60947-5-1
    AC-15 conforming to IEC 60947-5-1
    DC-12 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    safety reliability data
    MTTFd = 502.2 years
    B10d = 470000
    width
    17.5 mm
    product weight
    0.13 kg
    Environment
    electromagnetic compatibility
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to EN/IEC 61000-6-2
    standards
    EN/IEC 60255-1
    product certifications
    CSA
    C-Tick
    GL
    GOST
    UL
    directives
    89/336/EEC - electromagnetic compatibility
    73/23/EEC - low voltage directive
    ambient air temperature for storage
    -40...70 °C
    ambient air temperature for operation
    -20...50 °C
    relative humidity
    95 % at 55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6
    1 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1
    shock resistance
    15 gn for 11 ms conforming to IEC 60255-21-1
    IP degree of protection
    IP20 (terminals) conforming to IEC 60529
    IP30 (casing) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2 kV 1 min AC 50 Hz conforming to IEC 60255-5
    2 kV 1 min AC 50 Hz conforming to IEC 60664-1
    non-dissipating shock wave
    4 kV conforming to IEC 60255-5
    4 kV conforming to IEC 60664-1
    4 kV conforming to IEC 61000-4-5
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.