Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Sepam series 10
Schneider Electric REL59805 Image

REL59805

Green premium brand logo
Schneider Electric REL59805 Image
REL59805
Green premium brand logo

substat., transfo.- B41E - Sepam series 10

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Sepam series 10
    device short name
    B41E
    relay application
    Transformer
    Substation
    protection type
    Cold load pick-up Io CPLU 50N/51N
    Cold load pick-up CPLU 50/51
    Phase overcurrent 50/51
    Thermal overload protection 49RMS
    Earth fault/standard earth fault 50N/51N
    control and monitoring type
    Logic discrimination ANSI code: 68
    Annunciation ANSI code: 30
    Latching/acknowledgement ANSI code: 86
    metering type
    Earth-fault current
    Peak demand currents
    Phase currents
    network and machine diagnosis type
    Tripping context
    input output max capacity
    3 outputs
    communication compatibility
    IEC 60870-5-103
    Modbus RTU
    local signalling
    LEDs for fault indication (front face)
    LEDs for Sepam operating status (front face)
    number of outputs
    3 control relay
    output type
    Control relay: 100...240 V AC 47...63 Hz continuous current: 5 A breaking capacity: 5 kA cos φ > 0.3 making capacity: 30 A for 200 ms 2000 cycles
    Control relay: 127 V DC continuous current: 5 A breaking capacity: 0.7 kA resistive making capacity: 30 A for 200 ms 2000 cycles
    Control relay: 220 V DC continuous current: 5 A breaking capacity: 0.1 kA L/R < 40 ms making capacity: 30 A for 200 ms 2000 cycles
    Control relay: 220 V DC continuous current: 5 A breaking capacity: 0.3 kA resistive making capacity: 30 A for 200 ms 2000 cycles
    Control relay: 24 V DC continuous current: 5 A breaking capacity: 4 kA resistive making capacity: 30 A for 200 ms 2000 cycles
    Control relay: 24 V DC continuous current: 5 A breaking capacity: 5 kA L/R < 40 ms making capacity: 30 A for 200 ms 2000 cycles
    Control relay: 48 V DC continuous current: 5 A breaking capacity: 1 kA L/R < 40 ms making capacity: 30 A for 200 ms 2000 cycles
    Control relay: 48 V DC continuous current: 5 A breaking capacity: 4 kA resistive making capacity: 30 A for 200 ms 2000 cycles
    [Us] rated supply voltage
    100...240 V AC tolerance: +/- 20 %
    110...250 V DC tolerance: +/- 20 %
    supply inrush current
    < 20 A 0.1 ms
    power consumption in VA
    8 VA maximum
    3 VA typical
    mounting mode
    Fixed
    mounting support
    Plate
    Complementary
    height
    139 mm
    width
    179 mm
    depth
    123 mm
    net weight
    1.26 kg
    Environment
    standards
    CSA C22.2
    EN 50263
    UL 508
    product certifications
    CE
    UL 508 file N° 212533
    C22.2 file N° 210625
    fire resistance
    650 °C conforming to IEC 60695-2-11
    IP degree of protection
    Rear panel: IP40 conforming to IEC 60529
    Front panel: IP54 conforming to IEC 60529
    NEMA degree of protection
    Type 12 conforming to Nema type 250
    IK degree of protection
    IK07 conforming to IEC 62262
    power frequency dielectric withstand
    2 kV during 60 s conforming to IEC 60255-5
    [Uimp] rated impulse withstand voltage
    5 kV (1.2/50 µs) conforming to IEC 60255-5
    immunity to microbreaks
    100 ms conforming to CEI 60255-11
    electromagnetic compatibility
    Conducted emission: (tests), A, conforming to CISPR 22
    Conducted emission: (tests), A, conforming to EN 55022
    Conducted RF disturbances: (immunity tests-conducted disturbances), 10 V, 0.15...80 MHz, conforming to IEC 60255-22-6
    Conducted RF disturbances: (immunity tests-conducted disturbances), 3, 10 V, 0.15...80 MHz, conforming to IEC 61000-4-6
    Damped oscillatory wave: (immunity tests-conducted disturbances), 2.5 kV CM and DM, conforming to ANSI C37.90.1
    Damped oscillatory wave: (immunity tests-conducted disturbances), 2.5 kV DM, 1 kV DM, 100 kHz and 1 MHz, conforming to IEC 60255-22-1
    Damped oscillatory wave: (immunity tests-conducted disturbances), 3, 2.5 kV DM, 1 kV DM, 100 kHz and 1 MHz, conforming to IEC 61000-4-18
    Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to ANSI C37.90.3
    Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2
    Electrostatic discharge: (immunity tests-radiated disturbances), 3, 8 kV air, 6 kV contact, conforming to IEC 61000-4-2
    Fast transient bursts: (immunity tests-conducted disturbances), 4 kV CM and DM, 5 kHz, conforming to ANSI C37.90.1
    Fast transient bursts: (immunity tests-conducted disturbances), 4 kV CM, 5kHz, conforming to IEC 60255-22-4
    Fast transient bursts: (immunity tests-conducted disturbances), 4, 4 kV CM, 5kHz, conforming to IEC 61000-4-4
    Magnetic field at power frequency: (immunity tests-radiated disturbances), 4, 30 A/m (continuous) 100 A/m (for 1...3 s), conforming to IEC 61000-4-8
    Overall: (tests), A, conforming to IEC 60255-26
    Power frequency for status inputs: (immunity tests-conducted disturbances), 300 V CM, 150 V DM, conforming to IEC 60255-22-7
    Power frequency for status inputs: (immunity tests-conducted disturbances), 4, 300 V CM, 150 V DM, conforming to IEC 61000-4-16
    Radiated emission: (tests), A, conforming to CISPR 22
    Radiated emission: (tests), A, conforming to EN 55022
    Radiated RF fields: (immunity tests-radiated disturbances), 10 V/m, 80...1000 MHz, 1.4...2.7 GHz, conforming to IEC 60255-22-3
    Radiated RF fields: (immunity tests-radiated disturbances), 20 V/m, 80...1000 MHz, conforming to ANSI C37.90.2 (2004)
    Radiated RF fields: (immunity tests-radiated disturbances), 3, 10 V/m, 80 MHz...2000 MHz, conforming to IEC 61000-4-3
    Surges: (immunity tests-conducted disturbances), 1.2/50 µs, 10/700 µs, 2 kV CM, 1 kV DM, conforming to IEC 60255-22-5
    Surges: (immunity tests-conducted disturbances), 3, 1.2/50 µs, 10/700 µs, 2 kV CM, 1 kV DM, conforming to IEC 61000-4-5
    mechanical robustness
    Fire resistance enclosure protection: 650 °C conforming to IEC 60695-2-11
    Bumps de-energized (level: 2) : 20 Gn for 16 ms conforming to IEC 60255-21-2
    Earthquakes in operation (level: 2) : 2 Gn horizontal, 1 Gn vertical conforming to IEC 60255-21-3
    Front panel enclosure protection (level: IP54) conforming to IEC 60529
    Front panel enclosure protection (level: type 12) conforming to Nema type 250
    Rear panel enclosure protection (level: IP40) conforming to IEC 60529
    Shocks de-energized (level: 2) : 30 Gn for 11 ms conforming to IEC 60255-21-2
    Shocks enclosure protection (level: IK7) : 2 joules conforming to IEC 62262
    Shocks in operation (level: 2) : 10 Gn for 11 ms conforming to IEC 60255-21-2
    Vibrations de-energized (level: 2) : 2 Gn, 10...150 Hz, 20 cycle conforming to IEC 60255-21-1
    Vibrations in operation (level: 2) : 1 Gn, 10...150 Hz, 1 cycle conforming to IEC 60255-21-1
    climatic withstand
    Exposure to cold (storage in original packaging) : - 40 °C (104 °F), 96 h conforming to IEC 60068-2-1
    Corrosive atmosphere/2 gas test (in operation) : Ke: 21 days, 75 % RH, 25 °C (77 °F), 0.5 ppm H2S, 1 ppm SO2 conforming to IEC 60068-2-60
    Exposure to cold (in operation) : Ad: - 40 °C (104 °F), 96 h conforming to IEC 60068-2-1
    Exposure to damp heat (in operation) : Cab: 93 % RH, 40 °C, 56 days conforming to IEC 60068-2-78
    Exposure to damp heat (storage in original packaging) : Cab: 93 % RH, 40 °C, 56 days conforming to IEC 60068-2-78
    Exposure to dry heat (in operation) : Bd: 70 °C (158 °F), 96 h conforming to IEC 60068-2-2
    Exposure to dry heat (storage in original packaging) : Bd: 70 °C (158 °F), 96 h conforming to IEC 60068-2-2
    Salt mist (in operation) : Kb/2: 6 cycles conforming to IEC 60068-2-52
    Temperature variation (storage in original packaging) : Nb: 5 °C/min at - 40...70 °C (- 40...158 °F) conforming to IEC 60068-2-14
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
  • Documents

    Language
    • English
    • French
    • Italian
    • German
    User guide
    Date
    Size
    Add to My Documents
    Sepam série 10 - Manuel de référence (FR) (Version 2.0)
    CAD
    Date
    Size
    Add to My Documents
    Sepam serie 10 B (Version 1.0)
    Date 11/14/07
    Size 59.3 KB
    Date 11/14/07
    Size 8 KB
    Date 11/14/07
    Size 113.6 KB
    Date 11/14/07
    Size 23 KB
    Sepam serie 10 N (Version 1.0)
    Date 11/14/07
    Size 51.1 KB
    Date 11/14/07
    Size 4.8 KB
    Date 11/14/07
    Size 139.2 KB
    Date 11/14/07
    Size 8.9 KB
    Sepam serie 10 N (Version 1.0)
    Date 11/14/07
    Size 33.7 KB
    Date 11/14/07
    Size 4.2 KB
    Date 11/14/07
    Size 34.3 KB
    Date 11/14/07
    Size 4.7 KB
    Sepam serie 10 N (Version 1.0)
    Date 11/14/07
    Size 43.7 KB
    Date 11/14/07
    Size 5.8 KB
    Date 11/14/07
    Size 150.4 KB
    Date 11/14/07
    Size 6.6 KB
    Sepam serie 10 N (Version 1.0)
    Date 11/14/07
    Size 53.1 KB
    Date 11/14/07
    Size 4.9 KB
    Date 11/14/07
    Size 146.8 KB
    Date 11/14/07
    Size 11.5 KB
    Sepam serie 10 N (Version 1.0)
    Date 11/14/07
    Size 43.1 KB
    Date 11/14/07
    Size 6.7 KB
    Date 11/14/07
    Size 143.9 KB
    Date 11/14/07
    Size 4.6 KB
    Sepam serie 10 N (Version 1.0)
    Date 11/14/07
    Size 80.7 KB
    Date 11/14/07
    Size 12.1 KB
    Date 11/14/07
    Size 464 KB
    Date 11/14/07
    Size 11.5 KB
    Sepam serie 10 B (Version 1.0)
    Date 12/12/07
    Size 57.9 KB
    Date 12/12/07
    Size 10.6 KB
    Date 12/12/07
    Size 117.1 KB
    Date 12/12/07
    Size 20.6 KB
    Instruction sheet
    Date
    Size
    Add to My Documents
    Sepam series 10 B41 - Instruction sheet (EN, FR, IT, DE) (Version 02)
    Catalogue page
    Date
    Size
    Add to My Documents
    Sepam série 10 : catalogue (Version 2.0)
    Date 10/29/08
    Size 1.8 MB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 10/14/19
    Size 195.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 10/14/19
    Size 195.3 KB
    RoHs China Declaration
    Date
    Size
    Add to My Documents
    Date 10/14/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.