Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Zelio Timer Relays
Schneider Electric RE22R1QMQ Image

RE22R1QMQ

Green premium brand logo
Schneider Electric RE22R1QMQ Image
RE22R1QMQ
Green premium brand logo

star-delta timing relay - 230VAC/440VAC - 1 C/O

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Time
    product or component type
    Modular timing relay
    discrete output type
    Relay
    device short name
    RE22
    nominal output current
    8 A
    Complementary
    contacts type and composition
    1 C/O timed contact
    time delay type
    Q
    time delay range
    1...10 h
    10...100 h
    6...60 s
    1...10 min
    0.1...1 s
    1...10 s
    6...60 min
    control type
    Rotary knob front panel
    [Us] rated supply voltage
    380...440 V AC
    230...240 V AC
    voltage range
    0.85...1.1 Us
    supply frequency
    50...60 Hz +/- 5 %
    connections - terminals
    Screw terminals, 2 x 1.5 mm² with cable end
    Screw terminals, 2 x 2.5 mm² without cable end
    tightening torque
    0.6…1 N.m conforming to IEC 60947-1
    housing material
    Self-extinguishing
    repeat accuracy
    +/- 0.5 % conforming to IEC 61812-1
    temperature drift
    +/- 0.05 %/°C
    voltage drift
    +/- 0.2 %/V
    setting accuracy of time delay
    +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
    Control signal pulse width
    30 ms
    100 ms under load
    insulation resistance
    100 MOhm at 500 V DC conforming to IEC 60664-1
    Recovery time
    120 ms on de-energisation
    immunity to microbreaks
    10 ms
    power consumption in VA
    8 VA at 230...240 V
    17 VA at 380...440 V
    breaking capacity
    2000 VA
    minimum switching current
    10 mA at 5 V
    maximum switching current
    8 mA
    maximum switching voltage
    250 V
    electrical durability
    100000 cycles for resistive load, 8 A at 250 V, AC
    mechanical durability
    10000000 cycles
    Rated impulse withstand voltage
    5 kV for 1.2…50 µs conforming to IEC 60664-1
    5 kV conforming to IEC 61812-1
    Power on delay
    100 ms
    safety reliability data
    B10d = 260000
    MTTFd = 273.9 years
    mounting position
    Any position in relation to normal vertical mounting plane
    mounting support
    35 mm DIN rail conforming to EN/IEC 60715
    status LED
    LED green (flashing) for timing in progress
    LED green (steady) for power ON
    LED yellow for relay energised
    width
    22.5 mm
    net weight
    0.093 kg
    Environment
    dielectric strength
    2.5 kV for 1 mA/1 minute at 50 Hz conforming to IEC 61812-1
    standards
    EN 61000-6-4
    IEC 61812-1
    EN 61000-6-1
    EN 61000-6-3
    EN 61000-6-2
    directives
    2004/108/EC - electromagnetic compatibility
    2006/95/EC - low voltage directive
    product certifications
    CULus
    RCM
    CSA
    China RoHS
    EAC
    GL
    CCC
    CE
    ambient air temperature for operation
    -20…60 °C
    ambient air temperature for storage
    -30…60 °C
    IP degree of protection
    IP40 housing: conforming to IEC 60529
    IP20 terminal block: conforming to IEC 60529
    IP40 front face: conforming to IEC 60529
    vibration resistance
    20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
    shock resistance
    15 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity
    93 %, without condensation conforming to IEC 60068-2-30
    electromagnetic compatibility
    Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to EN/IEC 61000-4-2
    Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to EN/IEC 61000-4-2
    Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
    Fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
    Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
    Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
    Radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6
    Electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3
    Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
    Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
    Conducted and radiated emissions class B conforming to EN 55022
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
  • View more View less

    Documents

    Language
    • All Languages14
    • English12
    • Chinese3
    • Finnish3
    • French4
    • German3
    • Italian3
    • Spanish3
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 7.8 MB
    Date 1/14/19
    Size pdf
    Size 7.4 MB
    Date 2/11/19
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD file (on TraceParts) for RE22R1QMQ: star-delta timing relay - 230VAC/440VAC - 1 C/O (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    CAD file (on TraceParts) for RE22R1QMQ: star-delta timing relay - 230VAC/440VAC - 1 C/O (Version 2.0)
    Description
    You will be redirected to the Traceparts website. Register for free or log in to your Traceparts account to download more than 15 different 2D or 3D CAD formats.
    Size zip
    Size 1,015.5 KB
    Date 2/18/14
    Files in document
    Brochure
    Format
    Size
    Date
    Add to My Documents
    Teollisuuden Tähtituotteet 2 (Version 1.0)
    Description
    Teollisuuden Tähtituotteet 2: Harmony tasoasennus XB4, XB5 ja XB7 ohjauskalusteille • Ethernet kytkimet • Moottorikäynnistin TeSys H • Langaton ja paristoton OsiSense™ XCKW -rajakytkin • Zelio RM22 valvontareleet • Zelio RE22 aikareleet
    Size pdf
    Size 5.8 MB
    Date 5/10/16
    Description
    Teollisuuden Tähtituotteet 2: Harmony tasoasennus XB4, XB5 ja XB7 ohjauskalusteille • Ethernet kytkimet • Moottorikäynnistin TeSys H • Langaton ja paristoton OsiSense™ XCKW -rajakytkin • Zelio RM22 valvontareleet • Zelio RE22 aikareleet
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Zelio Timer RE22 and RENF22R2MMW (Version 1.0)
    Description
    RE22 and RENF22R2MMW CCC Certificate 2014010303687033
    Size pdf
    Size 1.7 MB
    Date 5/23/19
    Description
    RE22 and RENF22R2MMW CCC Certificate 2014010303687033
    UL Listed RE17, RE22, REXL, RE48A, RE88857, RE88865, RE88867, RENF22R2MMW (Version 1.0)
    Files in document
    pdf
    473.4 KB
    pdf
    475.7 KB
    Description
    NRNT_NRNT7_E173076_Timer New NFC Timer RENF22R2MMW
    Size zip
    Size 949 KB
    Date 5/19/15
    Files in document
    pdf
    473.4 KB
    pdf
    475.7 KB
    Description
    NRNT_NRNT7_E173076_Timer New NFC Timer RENF22R2MMW
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    EU DOC - Zelio Timer RE22 (Version 1.0)
    Description
    Manufacturer DOC-RE22 Juret/Sprint2 series
    Size pdf
    Size 243.3 KB
    Date 4/20/16
    Description
    Manufacturer DOC-RE22 Juret/Sprint2 series
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    star-delta timing relay - 230VAC/440VAC - 1 C/O
    Description
    star-delta timing relay - 230VAC/440VAC - 1 C/O
    Size pdf
    Size 195.3 KB
    Date 11/13/19
    Description
    star-delta timing relay - 230VAC/440VAC - 1 C/O
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    star-delta timing relay - 230VAC/440VAC - 1 C/O
    Description
    star-delta timing relay - 230VAC/440VAC - 1 C/O
    Size pdf
    Size 195.3 KB
    Date 11/13/19
    Description
    star-delta timing relay - 230VAC/440VAC - 1 C/O
    RoHs China Declaration
    Format
    Size
    Date
    Add to My Documents
    star-delta timing relay - 230VAC/440VAC - 1 C/O
    Description
    star-delta timing relay - 230VAC/440VAC - 1 C/O
    Size pdf
    Size 195.3 KB
    Date 11/13/19
    Description
    star-delta timing relay - 230VAC/440VAC - 1 C/O
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



  • Connections and Schema

    Internal Wiring Diagram



    Wiring Diagram



  • Technical Description

    Star-delta Timing Relay
    Description

    After power-up, the star contact closes instantly and timing T starts, At the end of timing period, the star contact opens.

    After a t ms pause, the delta contact closes and remains in this position.


    t : 20, 40, 60, 80, 100, 120, 140 ms

    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    R1 :

    Star contact output

    R2 :

    Delta contact output

    T :

    Timing period

    t :

    Delay to switch ON Delta contact output

    U :

    Supply


Compare products: /