
Circuit breaker Masterpact MTZ2 16H2, 1600 A, 3P drawout, without Micrologic
Show more characteristics >-
Characteristics
Main range Masterpactproduct name Masterpact MTZ2device short name MTZ2 16 H2product or component type Circuit breakerdevice application Protectionpoles description 3Pnetwork type ACnetwork frequency 50/60 Hzbreaking capacity code H2suitability for isolation Yes conforming to IEC 60947-2selectivity category Category BComplementary control type Push-buttonmounting mode Drawoutmounting support Base plateRails[In] rated current 1600 A ( 40 °C )[Ui] rated insulation voltage 1000 V conforming to IEC 60947-2 AC 50/60 Hz[Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2[Icm] rated short-circuit making capacity 220 kA peak at 220/415 V AC 50/60 Hz220 kA peak at 440 V AC 50/60 Hz187 kA peak at 500/525 V AC 50/60 Hz187 kA peak at 660/690 V AC 50/60 Hz[Ue] rated operational voltage 690 V conforming to IEC 60947-2 AC 50/60 Hzcircuit breaker CT rating 1600 Aperformance level 100 kA Icu conforming to IEC 60947-2 at 440 V AC 50/60 Hz100 kA Icu conforming to IEC 60947-2 at 220/415 V AC 50/60 Hz85 kA Icu conforming to IEC 60947-2 at 500/525 V AC 50/60 Hz85 kA Icu conforming to IEC 60947-2 at 660/690 V AC 50/60 Hz[Ics] rated service breaking capacity Ics 100 kA conforming to IEC 60947-2 at 220/415 V AC 50/60 HzIcs 100 kA conforming to IEC 60947-2 at 440 V AC 50/60 HzIcs 85 kA conforming to IEC 60947-2 at 500/525 V AC 50/60 HzIcs 85 kA conforming to IEC 60947-2 at 660/690 V AC 50/60 Hzmechanical durability 25000 cycles with periodic preventive maintenance conforming to IEC 60947-2electrical durability 10000 cycles conforming to IEC 60947-2 at 690 V AC 50/60 Hz10000 cycles conforming to IEC 60947-3 at 690 V AC 50/60 Hz AC-23A :10000 cycles conforming to IEC 60947-2 at 440 V AC 50/60 Hz10000 cycles conforming to IEC 60947-3 at 440 V AC 50/60 Hz AC-23A :6000 cycles conforming to IEC 60947-3 at 440/690 V AC 50/60 Hz AC-3 :connection pitch 115 mm[Icw] rated short-time withstand current 85 kA ( 0.5 s ) conforming to IEC 60947-250 kA ( 3 s ) conforming to IEC 60947-285 kA ( 1 s ) conforming to IEC 60947-2integral instant protection 171...209 kAmaximum breaking time 25 msclosing response time <= 70 msheight 300 mm drawout circuit breaker without chassis439 mm drawout circuit breaker with chassiswidth 378 mm drawout circuit breaker without chassis441 mm drawout circuit breaker with chassisdepth 300 mm drawout circuit breaker without chassis403 mm drawout circuit breaker with chassisEnvironment standards IEC 60947-2IEC 60364-8-1product certifications ASEFApollution degree 3 conforming to IEC 60947-1ambient air temperature for operation -25...70 °Cambient air temperature for storage -40...85 °COffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions -
Documents and Downloads
Language- English
- Spanish
- Portuguese
- Russian
- French
- Italian
- German
- Chinese
CatalogueSizeAdd to My DocumentsCatalog MasterPact MTZ 2019 - Air circuit breakers and switch-disconnectors (Version 3.0)Date 5/23/18Size 89.7 MBMasterPact MTZ - Catalogue numbers and spare parts 2019 - aIR circuit breakers and switch-disconnectors (Version 1.4)Date 2/6/19Size 9.2 MBMasterpact MTZ - Références et pièces détachées - Disjoncteurs et interrupteurs sectionneurs forte intensité (Version 1.1)Date 2/28/18Size 10.9 MBCatalogue MASTERPACT MTZ 2017 - Disjoncteurs et interrupteurs-sectionneurs forte intensité (Version 2.0)Date 5/31/18Size 86.9 MBUser guideSizeAdd to My DocumentsMasterpact MTZ - Basic and Standard Maintenance Procedures for IEC Devices (Version 02)Date 10/5/18Size 20.4 MBMasterpact MTZ2/MTZ3 - Circuit Breakers and Switch-Disconnectors from 800 to 6300 A - User Guide (Version 02)Date 6/8/18Size 11.3 MBMasterpact MTZ -Modbus Communication Guide (Version 04)Masterpact MTZ IEC Circuit Breakers and Switch-Disconnectors - Maintenance Guide (Version 02)Date 11/15/18Size 3.9 MBMasterpact MTZ - Cybersecurity Guide (Version 01)Masterpact MTZ Modbus 通信指南 (Version 04)Masterpact MTZ - Disjoncteurs et interrupteurs-sectionneurs CEI - Guide de maintenance (Version 02)Date 11/19/18Size 3.8 MBMasterpact MTZ2/MTZ3 - Disjoncteurs et interrupteurs de 800 à 6 300 A - Guide utilisateur (Version 02)Date 7/14/18Size 11.5 MBMasterpact MTZ2/MTZ3 - Interruptores automáticos e interruptores en carga de 800 a 6300 A - Guía del usuario (Version 02)Date 7/14/18Size 11.4 MBMasterpact MTZ - IEC 断路器和开关切断器 - 维护指南 (Version 02)Masterpact MTZ - Procedimientos de mantenimiento básico y estándar del usuario para aparatos IEC (Version 02)Date 11/19/18Size 22.9 MBMasterpact MTZ2/MTZ3 - 800-6300 A 断路器和开关切断器 - 用户指南 (Version 02)Masterpact MTZ Guía de comunicación Modbus (Version 04)Masterpact MTZ - Procédures de maintenance de base et standard utilisateur pour appareils IEC (Version 02)Date 11/19/18Size 20.4 MBMasterpact MTZ - Guide de cybersécurité (Version 01)Masterpact MTZ Guide de communication Modbus (Version 04)Masterpact MTZ - Interruptores automáticos e interruptores en carga IEC - Guía de mantenimiento (Version 02)Date 11/19/18Size 3.8 MBMasterpact MTZ - IEC 设备用户基本和标准维护程序 (Version 02)Masterpact MTZ - Guía de ciberseguridad (Version 01)CADSizeAdd to My DocumentsCircuit breaker Masterpact MTZ2 08...40 - 3P drawout - without Micrologic (Version 1.0)Date 12/13/17Size 1.3 MBDate 12/13/17Size 784.1 KBCAD files for LV848274: Circuit breaker Masterpact MTZ2 08….40 - 3P drawout - without Micrologic (Version 1.0)Date 1/25/19Size 338.6 KBSB111973_3D-Simplified (Version 1.0)Instruction sheetSizeAdd to My DocumentsMasterpact MTZ2/MTZ3 - Drawout Circuit Breaker or Switch-Disconnector (Version 02)Date 9/27/18Size 44.4 MBMicrologic X - Radio Frequency Compliance Statements (Version 03)End of Life InformationSizeAdd to My DocumentsEoLI-Masterpact MTZ2 25H1 three pole draw out circuit breaker with Micrologic 5.0X control unit (Version 1.0)Date 5/5/17Size 470.2 KBEU RoHS DeclarationSizeAdd to My DocumentsProduct Environmental ProfileSizeAdd to My DocumentsPEP-Masterpact MTZ2 25H1 three pole draw out circuit breaker with Micrologic 5.0X control unit (Version 1.0)PEP-Masterpact MTZ2 25H1 three pole draw out circuit breaker with Micrologic 5.0X control unit (pdf)Date 5/5/17Size 458.5 KBREACh DeclarationSizeAdd to My DocumentsSoftware - Release NotesSizeAdd to My DocumentsMasterpact MTZ Micrologic X Control Unit - Firmware Release Note (Version 04) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.