Circuit breaker Masterpact MTZ2 16H1, 1600 A, 4P drawout, right N, no Micrologic
Show more characteristics >-
Characteristics
Main range Masterpactproduct name Masterpact MTZ2device short name MTZ2 16 H1product or component type Circuit breakerdevice application Protectionpoles description 4Pneutral position Rightnetwork type ACnetwork frequency 50/60 Hzbreaking capacity code H1suitability for isolation Yes conforming to IEC 60947-2selectivity category Category BComplementary control type Push-buttonmounting mode Drawoutmounting support Base plateRails[In] rated current 1600 A ( 40 °C )[Ui] rated insulation voltage 1000 V conforming to IEC 60947-2 AC 50/60 Hz[Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2[Icm] rated short-circuit making capacity 145 kA peak at 220/415 V AC 50/60 Hz145 kA peak at 440 V AC 50/60 Hz145 kA peak at 500/525 V AC 50/60 Hz145 kA peak at 660/690 V AC 50/60 Hz[Ue] rated operational voltage 690 V conforming to IEC 60947-2 AC 50/60 Hzcircuit breaker CT rating 1600 Aperformance level 66 kA Icu conforming to IEC 60947-2 at 440 V AC 50/60 Hz66 kA Icu conforming to IEC 60947-2 at 220/415 V AC 50/60 Hz66 kA Icu conforming to IEC 60947-2 at 500/525 V AC 50/60 Hz66 kA Icu conforming to IEC 60947-2 at 660/690 V AC 50/60 Hz[Ics] rated service breaking capacity Ics 66 kA conforming to IEC 60947-2 at 220/415 V AC 50/60 HzIcs 66 kA conforming to IEC 60947-2 at 440 V AC 50/60 HzIcs 66 kA conforming to IEC 60947-2 at 500/525 V AC 50/60 HzIcs 66 kA conforming to IEC 60947-2 at 660/690 V AC 50/60 Hzmechanical durability 25000 cycles with periodic preventive maintenance conforming to IEC 60947-2electrical durability 10000 cycles conforming to IEC 60947-2 at 690 V AC 50/60 Hz10000 cycles conforming to IEC 60947-3 at 690 V AC 50/60 Hz AC-23A :10000 cycles conforming to IEC 60947-2 at 440 V AC 50/60 Hz10000 cycles conforming to IEC 60947-3 at 440 V AC 50/60 Hz AC-23A :6000 cycles conforming to IEC 60947-3 at 440/690 V AC 50/60 Hz AC-3 :connection pitch 115 mm[Icw] rated short-time withstand current 66 kA ( 0.5 s ) conforming to IEC 60947-266 kA ( 1 s ) conforming to IEC 60947-236 kA ( 3 s ) conforming to IEC 60947-2maximum breaking time 25 msclosing response time <= 70 msheight 300 mm drawout circuit breaker without chassis439 mm drawout circuit breaker with chassiswidth 493 mm drawout circuit breaker without chassis556 mm drawout circuit breaker with chassisdepth 300 mm drawout circuit breaker without chassis403 mm drawout circuit breaker with chassisEnvironment standards IEC 60947-2IEC 60364-8-1product certifications ASTApollution degree 3 conforming to IEC 60947-1ambient air temperature for operation -25...70 °Cambient air temperature for storage -40...85 °COffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile AvailableProduct end of life instructions Available -
Documents and Downloads
Language- English
- Spanish
- Portuguese
- Russian
- French
- Italian
- German
- Chinese
CatalogueSizeAdd to My DocumentsCatalog MasterPact MTZ 2019 - Air circuit breakers and switch-disconnectors (Version 3.0)Date 5/23/18Size 89.7 MBMasterPact MTZ - Catalogue numbers and spare parts 2019 - aIR circuit breakers and switch-disconnectors (Version 1.4)Date 2/6/19Size 9.2 MBMasterpact MTZ - Références et pièces détachées - Disjoncteurs et interrupteurs sectionneurs forte intensité (Version 1.1)Date 2/28/18Size 10.9 MBCatalogue MASTERPACT MTZ 2017 - Disjoncteurs et interrupteurs-sectionneurs forte intensité (Version 2.0)Date 5/31/18Size 86.9 MBUser guideSizeAdd to My DocumentsMasterpact MTZ - Basic and Standard Maintenance Procedures for IEC Devices (Version 02)Date 10/5/18Size 20.4 MBMasterpact MTZ2/MTZ3 - Circuit Breakers and Switch-Disconnectors from 800 to 6300 A - User Guide (Version 02)Date 6/8/18Size 11.3 MBMasterpact MTZ -Modbus Communication Guide (Version 04)Masterpact MTZ IEC Circuit Breakers and Switch-Disconnectors - Maintenance Guide (Version 02)Date 11/15/18Size 3.9 MBMasterpact MTZ - Cybersecurity Guide (Version 01)Masterpact MTZ Modbus 通信指南 (Version 04)Masterpact MTZ - Disjoncteurs et interrupteurs-sectionneurs CEI - Guide de maintenance (Version 02)Date 11/19/18Size 3.8 MBMasterpact MTZ2/MTZ3 - Disjoncteurs et interrupteurs de 800 à 6 300 A - Guide utilisateur (Version 02)Date 7/14/18Size 11.5 MBMasterpact MTZ2/MTZ3 - Interruptores automáticos e interruptores en carga de 800 a 6300 A - Guía del usuario (Version 02)Date 7/14/18Size 11.4 MBMasterpact MTZ - IEC 断路器和开关切断器 - 维护指南 (Version 02)Masterpact MTZ - Procedimientos de mantenimiento básico y estándar del usuario para aparatos IEC (Version 02)Date 11/19/18Size 22.9 MBMasterpact MTZ2/MTZ3 - 800-6300 A 断路器和开关切断器 - 用户指南 (Version 02)Masterpact MTZ Guía de comunicación Modbus (Version 04)Masterpact MTZ - Procédures de maintenance de base et standard utilisateur pour appareils IEC (Version 02)Date 11/19/18Size 20.4 MBMasterpact MTZ - Guide de cybersécurité (Version 01)Masterpact MTZ Guide de communication Modbus (Version 04)Masterpact MTZ - Interruptores automáticos e interruptores en carga IEC - Guía de mantenimiento (Version 02)Date 11/19/18Size 3.8 MBMasterpact MTZ - IEC 设备用户基本和标准维护程序 (Version 02)Masterpact MTZ - Guía de ciberseguridad (Version 01)CADSizeAdd to My DocumentsCAD files for LV848229: Circuit breaker MTZ2 08...40 - 4P drawout - right neutral - w/o Micrologic (Version 1.0)Date 2/6/19Size 325.3 KBCircuit breaker MTZ2 08...40 - 4P drawout - right neutral - w/o Micrologic (Version 1.0)Date 12/11/17Size 4.7 MBInstruction sheetSizeAdd to My DocumentsMasterpact MTZ2/MTZ3 - Fixed Circuit Breaker or Switch-Disconnector (Version 02)Micrologic X - Radio Frequency Compliance Statements (Version 03)Software - Release NotesSizeAdd to My DocumentsMasterpact MTZ Micrologic X Control Unit - Firmware Release Note (Version 04) -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.