Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Tesys T
Schneider Electric LTMR08PFM Image

LTMR08PFM

Green premium brand logo
Schneider Electric LTMR08PFM Image
LTMR08PFM
Green premium brand logo

motor controller LTMR TeSys T - 100..240 V AC 8 A for Profibus DP

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys T
    device short name
    LTMR
    product or component type
    Motor controller
    device application
    Equipment monitoring and control
    measurement current
    0.4…8 A
    [Us] rated supply voltage
    100...240 V AC 50/60 Hz
    current consumption
    8...62.8 mA
    supply voltage limits
    93.5…264 V AC
    communication port protocol
    Profibus DP
    bus type
    Profibus DP polarised 2-wire RS485 interface, addressing 1...125, transmission rate 9.6 kbit/s...12 Mbit/s, SUB-D 9 with 2 shielded twisted pairs, type A
    Profibus DP polarised 2-wire RS485 interface, addressing 1...125, transmission rate 9.6 kbit/s...12 Mbit/s, terminal block with 2 shielded twisted pairs, type A
    Complementary
    [Ui] rated insulation voltage
    690 V conforming to EN/IEC 60947-1
    690 V conforming to CSA C22.2 No 14
    690 V conforming to UL 508
    [Uimp] rated impulse withstand voltage
    4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
    6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
    0.8 kV communication circuit conforming to EN/IEC 60947-4-1
    short-circuit withstand
    100 kA conforming to EN/IEC 60947-4-1
    associated fuse rating
    4 A gG for output
    0.5 A gG for control circuit
    protection type
    Locked rotor
    Overload
    Phase unbalance
    Phase failure
    Earth-leakage protection
    Reverse polarity protection
    Load fluctuation
    Thermal protection
    Power factor variation
    Thermal overload protection
    Overload (long time)
    network and machine diagnosis type
    Phase fault and earth fault trip counters
    Trip history information
    Starting current and time
    Fault recording
    Waiting time after overload tripping
    Event recording
    Motor control command recording
    Running hours counter/operating time
    Trip context information
    Remaining operating time before overload tripping
    logic input number
    6
    input current
    3.1 mA at 100 V
    7.5 mA at 240 V
    current state 0 guaranteed
    Logic input: 0...40 V and <= 15 mA for 25 ms
    current state 1 guaranteed
    Logic input: 79...264 V and >= 2 mA for 25 ms
    maximum output switching frequency
    2 Hz
    load current
    5 A at 250 V AC for logic output
    5 A at 30 V DC for logic output
    permissible power
    480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
    30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
    maximum operating rate
    1800 cyc/h
    contacts type and composition
    1 NO + 1 NC fault signal
    3 NO
    metering type
    Average current Iavg
    Earth-fault current
    Temperature
    Imbalance current
    Phase current I1, I2, I3 RMS
    measurement accuracy
    5...15 % earth fault current internal measurement (for current > 0.1 A)
    1 % voltage (100...830 V)
    3 % power factor (cos φ > 0.6)
    5 % earth fault current external measurement (< 5 % or 0.01 A)
    +/- 30 min/year internal clock
    0,02 temperature
    1 % current
    5 % active and reactive power
    overvoltage category
    III
    connection pitch
    5.08 mm
    connections - terminals
    Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
    Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
    Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
    Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
    Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
    Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
    Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
    Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
    tightening torque
    Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
    pollution degree
    3
    electromagnetic compatibility
    Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
    Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
    Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
    Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
    Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
    Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
    Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
    Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
    Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
    Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
    Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
    Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
    Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
    width
    91 mm
    height
    61 mm
    depth
    122.5 mm
    net weight
    0.53 kg
    web services
    Web server
    compatibility code
    LTMR
    Environment
    standards
    UL 508
    IEC 60947-4-1
    EN 60947-4-1
    IACS E10
    CSA C22.2 No 14
    product certifications
    CSA
    C-Tick
    UL
    CCC
    LROS (Lloyds register of shipping)
    NOM
    ABS
    GL
    EAC
    BV
    DNV
    RINA
    RMRoS
    ATEX
    KERI
    protective treatment
    12 x 24 hour cycles conforming to EN/IEC 60068-2-30
    48 h conforming to EN/IEC 60070-2-11
    TH conforming to EN/IEC 60068
    fire resistance
    650 °C conforming to EN/IEC 60695-2-12
    960 °C conforming to UL 94
    ambient air temperature for operation
    -20…60 °C
    ambient air temperature for storage
    -40…80 °C
    operating altitude
    <= 2000 m without derating
    mechanical robustness
    Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
    Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
    Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
    IP degree of protection
    IP20
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Under investigation
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • Documents

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • Chinese
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)
    TeSys catalogue - 2019 - 2020 - chapter B12 Motor management systems TeSys LUTM, T (Version 6.0)
    Catalogue TeSys 2019 - Chapitre B12 - Controleurs de moteurs (Version 4.0)
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    User guide
    Date
    Size
    Add to My Documents
    TeSys T DTM für FDT Container & Anwenderspezifischer Logik-Editor - Online-Hilfe (Version 01)
    TeSys T DTM pour le conteneur FDT & Editeur de programme applicatif - Aide en ligne (Version 01)
    DTM TeSys T per il contenitore FDT & Editor di logica personalizzata - Guida in linea (Version 01)
    FDT 容器的 TeSysT DTM - 自定义逻辑编辑器 - 联机帮助 (Version 01)
    TeSys T DTM for FDT Container & Custom Logic Editor - Online Help (Version 01)
    TeSys T DTM para el contenedor de FDT & Editor de lógica personalizada - Ayuda en línea (Version 01)
    TeSys DFB Offer V2 for PL7 - User manual (Version 2.0)
    Offre TeSys DFB V2 pour PL7 - Manuel d'utilisation (Version 2.1)
    Offre TeSys DFB V2 pour PL7 - Manuel d'utilisation (Version 2.0)
    Offre TeSys DFB V2 pour PL7 - Manuel d'utilisation (Version 2.0)
    Offre TeSys DFB V2 pour PL7 - Manuel d'utilisation (Version 2.0)
    Offre TeSys DFB V2 pour PL7 - Manuel d'utilisation (Version 1.0)
    TeSys T - Use in explosive atmospheres (Version 04)
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.0)
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.1)
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.0)
    TeSys DFB Offer for V2 Unity Pro - User manual (Version 1.0)
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.0)
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.0)
    LTM R Profibus - Quick Start (Version 2.1)
    Date 12/1/10
    Size 1.5 MB
    CAD
    Date
    Size
    Add to My Documents
    Motor controller LTMR TeSys T - 100..240 V AC 8 A for Profibus DP (Version 1.0)
    Motor controller LTMR TeSys T - 100..240 V AC 8 A for Profibus DP (Version 1.0)
    ProfiBus relay (Version 1.0)
    Date 3/27/14
    Size 906.8 KB
    Date 3/27/14
    Size 886.9 KB
    CAD file (on TraceParts) for LTMR08PFM: motor controller LTMR TeSys T - 100..240 V AC 8 A for Profibus DP (Version 2.0)
    Brochure
    Date
    Size
    Add to My Documents
    TeSys T LTMCUF promotional leaflet (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    CB Certificate TeSys T, LTMR/LTMEV, made in China, according to IEC 60947-4-1 Ed3 (Version 1.0)
    CB Certificate TeSys T, LTMR/LTMEV, made in China, according to IEC 60947-4-1 Ed3 (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    LTM R - Motor management controller - Instruction sheet (Version 07)
    End of Life Information
    Date
    Size
    Add to My Documents
    End-of-Life Instructions TeSys T (Version 2.0)
    Date 3/31/16
    Size 218.7 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Motor management system (Version 2.0)
    Date 3/31/16
    Size 287.1 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    RoHs China Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /