Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Tesys T
Schneider Electric LTMR08DBD Image

LTMR08DBD

Schneider Electric LTMR08DBD Image
LTMR08DBD

motor controller LTMR TeSys T - 24 V DC 8 A for DeviceNet

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys T
    device short name
    LTMR
    product or component type
    Motor controller
    device application
    Equipment monitoring and control
    measurement current
    0.4...8 A
    [Us] rated supply voltage
    24 V DC
    current consumption
    56...127 mA
    supply voltage limits
    20.4...26.24 V DC
    communication port protocol
    DeviceNet
    bus type
    DeviceNet ISO 1198 interface, addressing 1...64, transmission rate 125...500 kbit/s, terminal block with 4 twisted shielded pairs cable
    Complementary
    [Ui] rated insulation voltage
    690 V conforming to CSA C22.2 No 14
    690 V conforming to EN/IEC 60947-1
    690 V conforming to UL 508
    [Uimp] rated impulse withstand voltage
    6 kV for current or voltage measurement circuit conforming to EN/IEC 60947-4-1
    0.8 kV for communication circuit conforming to EN/IEC 60947-4-1
    0.8 kV for supply, inputs and outputs conforming to EN/IEC 60947-4-1
    short-circuit withstand
    100 kA conforming to EN/IEC 60947-4-1
    associated fuse rating
    0.5 A gG for control circuit
    4 A gG for output
    protection type
    Overload (long time)
    Power factor variation
    Phase failure
    Thermal overload protection
    Thermal protection
    Locked rotor
    Phase unbalance
    Load fluctuation
    Overload
    Reverse polarity protection
    Earth-leakage protection
    network and machine diagnosis type
    Waiting time after overload tripping
    Phase fault and earth fault trip counters
    Event recording
    Running hours counter/operating time
    Motor control command recording
    Trip history information
    Remaining operating time before overload tripping
    Fault recording
    Trip context information
    Starting current and time
    logic input number
    6
    input current
    7 mA
    current state 0 guaranteed
    Logic input : < 5 V and <= 15 mA for 5 ms
    current state 1 guaranteed
    Logic input : < 15 V and 2...15 mA for 15 ms
    maximum output switching frequency
    2 Hz
    load current
    5 A at 250 V AC for logic output
    5 A at 30 V DC for logic output
    permissible power
    480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
    30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
    operating rate
    1800 cyc/h
    contacts type and composition
    1 NO + 1 NC fault signal
    3 NO
    metering type
    Imbalance current
    Average current Iavg
    Earth-fault current
    Phase current I1, I2, I3 RMS
    Temperature
    measurement accuracy
    3 % power factor (cos φ > 0.6)
    +/- 30 min/year internal clock
    0,02 temperature
    5...15 % earth fault current internal measurement (for current > 0.1 A)
    1 % current
    1 % voltage (100...830 V)
    5 % active and reactive power
    5 % earth fault current external measurement (< 5 % or 0.01 A)
    overvoltage category
    III
    connection pitch
    5.08 mm
    connections - terminals
    Connector, 1 flexible cable with cable end 0.25...2.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 1 flexible cable without cable end 0.2...2.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 1 flexible cable without cable end 0.25...2.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 1 solid cable without cable end 0.2...2.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 2 flexible cable with cable end 0.2...1 mm² /AWG 24...AWG 14 for control circuit
    Connector, 2 flexible cable without cable end 0.2...1.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 2 flexible cable without cable end 0.5...1.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 2 solid cable without cable end 0.2...1 mm² /AWG 24...AWG 14 for control circuit
    tightening torque
    0.5...0.6 N.m, 3 mm flat screwdriver for control circuit
    pollution degree
    3
    electromagnetic compatibility
    ● electrostatic discharge 3 (8 kV air, 6 kV contact), conforming to EN/IEC 61000-4-2
    ● fast transients immunity test other circuits level 3 (2 kV), conforming to EN/IEC 61000-4-4
    ● fast transients immunity test on supply and relay outputs level 4 (4 kV), conforming to EN/IEC 61000-4-4
    ● conducted RF disturbances (10 V), conforming to EN/IEC 61000-4-6
    ● surges common mode (1 kV) control circuit, conforming to EN/IEC 61000-4-5
    ● surges serial mode (1 kV) control circuit, conforming to EN/IEC 61000-4-5
    ● surges common mode (2 kV) communication, conforming to EN/IEC 61000-4-5
    ● radiated RF fields 3 (10 V/m), conforming to EN/IEC 61000-4-3
    ● voltage dips and interruptions immunity test (70 %, 500 ms), conforming to EN/IEC 61000-4-11
    ● surges serial mode (0.5 kV) temperature sensor, conforming to EN/IEC 61000-4-5
    ● surges common mode (1 kV) temperature sensor, conforming to EN/IEC 61000-4-5
    ● surges serial mode (2 kV) relay outputs and supply, conforming to EN/IEC 61000-4-5
    ● surges common mode (4 kV) relay outputs and supply, conforming to EN/IEC 61000-4-5
    width
    91 mm
    height
    61 mm
    depth
    122.5 mm
    product weight
    0.53 kg
    web services
    Web server
    compatibility code
    LTMR
    Environment
    standards
    EN 60947-4-1
    IACS E10
    UL 508
    IEC 60947-4-1
    CSA C22.2 No 14
    product certifications
    UL
    DNV
    ABS
    KERI
    CCC
    RINA
    NOM
    C-Tick
    RMRoS
    GL
    LROS (Lloyds register of shipping)
    ATEX
    CSA
    EAC
    BV
    protective treatment
    12 x 24 hour cycles conforming to EN/IEC 60068-2-30
    48 h conforming to EN/IEC 60070-2-11
    TH conforming to EN/IEC 60068
    fire resistance
    650 °C conforming to EN/IEC 60695-2-12
    960 °C conforming to UL 94
    ambient air temperature for operation
    -20...60 °C
    ambient air temperature for storage
    -40...80 °C
    operating altitude
    <= 2000 m without derating
    mechanical robustness
    ● shocks half sine wave acceleration (15 Gn for 11 ms) conforming to EN/IEC 60068-2-27
    ● vibrations mounted on symmetrical rail (1 Gn, 5...300 Hz) conforming to EN/IEC 60068-2-6
    ● vibrations plate mounted (4 Gn, 5...300 Hz) conforming to EN/IEC 60068-2-6
    IP degree of protection
    IP20
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  0501  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Product end of life instructions
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • Chinese
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)
    Catalogue TeSys 2019 - Chapitre B12 - Controleurs de moteurs (Version 4.0)
    TeSys catalogue - 2019 - 2020 - chapter B12 Motor management systems TeSys LUTM, T (Version 6.0)
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    User guide
    Date
    Size
    Add to My Documents
    TeSys T - Use in explosive atmospheres (Version 04)
    LTM R DeviceNet - Quick Start (Version 2.1)
    Date 12/1/10
    Size 1.7 MB
    TeSys T DTM for FDT Container & Custom Logic Editor - Online Help (Version 01)
    TeSys T DTM pour le conteneur FDT & Editeur de programme applicatif - Aide en ligne (Version 01)
    TeSys T DTM für FDT Container & Anwenderspezifischer Logik-Editor - Online-Hilfe (Version 01)
    TeSys T DTM para el contenedor de FDT & Editor de lógica personalizada - Ayuda en línea (Version 01)
    DTM TeSys T per il contenitore FDT & Editor di logica personalizzata - Guida in linea (Version 01)
    FDT 容器的 TeSysT DTM - 自定义逻辑编辑器 - 联机帮助 (Version 01)
    CAD
    Date
    Size
    Add to My Documents
    Motor controller LTMR TeSys T - 24 V DC 8 A for DeviceNet (Version 1.0)
    CAD file (on TraceParts) for LTMR08DBD: motor controller LTMR TeSys T - 24 V DC 8 A for DeviceNet (Version 2.0)
    Motor controller LTMR TeSys T - 24 V DC 8 A for DeviceNet (Version 1.0)
    DeviceNet relay (Version 1.0)
    Date 3/27/14
    Size 1.1 MB
    Date 3/27/14
    Size 405.6 KB
    Certificate
    Date
    Size
    Add to My Documents
    CB Certificate TeSys T, LTMR/LTMEV, made in China, according to IEC 60947-4-1 Ed3 (Version 1.0)
    CB Certificate TeSys T, LTMR/LTMEV, made in China, according to IEC 60947-4-1 Ed3 (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    LTM R - Motor management controller - Instruction sheet (Version 07)
    End of Life Information
    Date
    Size
    Add to My Documents
    End-of-Life Instructions TeSys T (Version 2.0)
    Date 3/31/16
    Size 218.7 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 9/15/19
    Size 195.3 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Motor management system (Version 2.0)
    Date 3/31/16
    Size 287.1 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 9/15/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.