Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Tesys T
Schneider Electric LTMR08CBD Image

LTMR08CBD

Green premium brand logo
Schneider Electric LTMR08CBD Image
LTMR08CBD
Green premium brand logo

motor controller LTMR TeSys T - 24 V DC 8 A for CANopen

Show more characteristics
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys T
    device short name
    LTMR
    product or component type
    Motor controller
    device application
    Equipment monitoring and control
    measurement current
    0.4…8 A
    [Us] rated supply voltage
    24 V DC
    current consumption
    56...127 mA
    supply voltage limits
    20.4…26.24 V DC
    communication port protocol
    CANopen
    bus type
    CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cable
    CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, terminal block with 4 twisted shielded pairs cable
    Complementary
    [Ui] rated insulation voltage
    690 V conforming to EN/IEC 60947-1
    690 V conforming to CSA C22.2 No 14
    690 V conforming to UL 508
    [Uimp] rated impulse withstand voltage
    6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
    0.8 kV communication circuit conforming to EN/IEC 60947-4-1
    0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
    short-circuit withstand
    100 kA conforming to EN/IEC 60947-4-1
    associated fuse rating
    4 A gG for output
    0.5 A gG for control circuit
    protection type
    Overload (long time)
    Phase failure
    Load fluctuation
    Phase imbalance
    Reverse polarity protection
    Thermal protection
    Thermal overload protection
    Earth-leakage protection
    Power factor variation
    Overload
    Locked rotor
    network and machine diagnosis type
    Trip context information
    Remaining operating time before overload tripping
    Starting current and time
    Event recording
    Motor control command recording
    Running hours counter/operating time
    Waiting time after overload tripping
    Trip history information
    Phase fault and earth fault trip counters
    Fault recording
    logic input number
    6
    input current
    7 mA
    current state 0 guaranteed
    Logic input: < 5 V and <= 15 mA for 5 ms
    current state 1 guaranteed
    Logic input: < 15 V and 2...15 mA for 15 ms
    maximum output switching frequency
    2 Hz
    load current
    5 A at 250 V AC for logic output
    5 A at 30 V DC for logic output
    permissible power
    480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
    30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
    maximum operating rate
    1800 cyc/h
    contacts type and composition
    1 NO + 1 NC fault signal
    3 NO
    metering type
    Average current Iavg
    Phase current I1, I2, I3 RMS
    Temperature
    Earth-fault current
    Imbalance current
    measurement accuracy
    5...15 % earth fault current internal measurement (for current > 0.1 A)
    1 % voltage (100...830 V)
    3 % power factor (cos φ > 0.6)
    5 % earth fault current external measurement (< 5 % or 0.01 A)
    +/- 30 min/year internal clock
    0,02 temperature
    1 % current
    5 % active and reactive power
    overvoltage category
    III
    connection pitch
    5.08 mm
    connections - terminals
    Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
    Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
    Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
    Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
    Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
    Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
    Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
    Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
    tightening torque
    Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
    pollution degree
    3
    electromagnetic compatibility
    Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
    Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
    Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
    Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
    Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
    Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
    Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
    Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
    Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
    Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
    Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
    Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
    Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
    width
    91 mm
    height
    61 mm
    depth
    122.5 mm
    net weight
    0.53 kg
    web services
    Web server
    compatibility code
    LTMR
    Environment
    standards
    EN 60947-4-1
    CSA C22.2 No 14
    IEC 60947-4-1
    UL 508
    IACS E10
    product certifications
    ATEX
    C-Tick
    EAC
    LROS (Lloyds register of shipping)
    NOM
    BV
    RINA
    KERI
    ABS
    UL
    CSA
    DNV
    RMRoS
    GL
    CCC
    protective treatment
    12 x 24 hour cycles conforming to EN/IEC 60068-2-30
    48 h conforming to EN/IEC 60070-2-11
    TH conforming to EN/IEC 60068
    fire resistance
    650 °C conforming to EN/IEC 60695-2-12
    960 °C conforming to UL 94
    ambient air temperature for operation
    -20…60 °C
    ambient air temperature for storage
    -40…80 °C
    operating altitude
    <= 2000 m without derating
    mechanical robustness
    Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
    Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
    Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
    IP degree of protection
    IP20
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    China RoHS declaration
    Product out of China RoHS scope. Substance declaration for your information
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages37
    • English20
    • Chinese9
    • French16
    • German9
    • Italian9
    • Portuguese6
    • Russian6
    • Spanish9
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    Description
    Ready-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    Size pdf
    Size 111.5 MB
    Date 7/12/19
    Description
    Ready-to-use motor starters and all components for builiding specific motor starters ( ircuit breakers, contactors, overload relays , accessories ...).The catalogue can also be downloaded chapter per chapter.
    TeSys catalogue - 2019 - 2020 - chapter B12 Motor management systems TeSys LUTM, T (Version 6.0)
    Description
    Motor overload protection, alarms, communication functions : TeSys LUTMMotor overload protection, alarm, measurement functions : TeSys T
    Size pdf
    Size 3.4 MB
    Date 5/15/19
    Description
    Motor overload protection, alarms, communication functions : TeSys LUTMMotor overload protection, alarm, measurement functions : TeSys T
    Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)
    Description
    Le catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.
    Size pdf
    Size 108.2 MB
    Date 7/12/19
    Description
    Le catalogue est aussi accessible chapitre par chapitre. Faire une recherche "A1 -" par exemple pour le chapitre A1.Les fichiers sources sont accessibles chapitre par chapitre: un fichier zip par chapitre. Pour les obtenir facilement, lancer la recherche "catalogue tesys" dans Shopping Kiosk, les accès à chaque chapitre seront proposés sur une même page.Le fichier Excel "TeSys catalogue 2016 structure" donne la liste des fichiers composant le catalogue.
    Catalogue TeSys 2019 - Chapitre B12 - Controleurs de moteurs (Version 4.0)
    Description
    Présentation des contrôleurs pour la surveillance des moteurs: surveillance dintensité, de tension, avec génération dalarme, communication sur bus selon modèle
    Size pdf
    Size 4.4 MB
    Date 6/11/19
    Description
    Présentation des contrôleurs pour la surveillance des moteurs: surveillance dintensité, de tension, avec génération dalarme, communication sur bus selon modèle
    User guide
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 826.1 KB
    Date 11/1/18
    TeSys DFB Offer for V2 Unity Pro - User manual (Version 1.0)
    Description
    TeSys DFB Offer for V2 Unity Pro - User manual
    Size pdf
    Size 991.2 KB
    Date 9/15/09
    Description
    TeSys DFB Offer for V2 Unity Pro - User manual
    Size pdf
    Size 2.6 MB
    Date 9/15/09
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.0)
    Description
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation
    Size pdf
    Size 1.1 MB
    Date 9/15/09
    Description
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation
    Size pdf
    Size 2.6 MB
    Date 9/15/09
    Size pdf
    Size 1.5 MB
    Date 12/1/10
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.1)
    Description
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation
    Size pdf
    Size 1 MB
    Date 10/7/09
    Description
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation
    Size pdf
    Size 2.7 MB
    Date 10/7/09
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.0)
    Description
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation
    Size pdf
    Size 1 MB
    Date 9/15/09
    Description
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation
    Size pdf
    Size 2.7 MB
    Date 9/28/08
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.0)
    Description
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation
    Size pdf
    Size 1,021 KB
    Date 9/15/09
    Description
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation
    Size pdf
    Size 2.7 MB
    Date 9/28/08
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation (Version 1.0)
    Description
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation
    Size pdf
    Size 1,021.1 KB
    Date 9/15/09
    Description
    Offre TeSys DFB V2 pour Unity Pro - Manuel d'utilisation
    Size pdf
    Size 2.7 MB
    Date 9/15/09
    CAD
    Format
    Size
    Date
    Add to My Documents
    Size zip
    Size 1.7 MB
    Date 6/26/18
    Files in document
    Size dwg
    Size 849 KB
    Date 6/26/18
    CANopen relay (Version 1.0)
    Files in document
    Size zip
    Size 1.5 MB
    Date 3/27/14
    Files in document
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 4.2 MB
    Date 7/31/18
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 288.2 KB
    Date 6/28/19
    End of Life Information
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 218.7 KB
    Date 3/31/16
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    motor controller LTMR TeSys T - 24 V DC 8 A for CANopen
    Description
    motor controller LTMR TeSys T - 24 V DC 8 A for CANopen
    Size pdf
    Size 195.3 KB
    Date 11/12/19
    Description
    motor controller LTMR TeSys T - 24 V DC 8 A for CANopen
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 287.1 KB
    Date 3/31/16
    Description
    None
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    motor controller LTMR TeSys T - 24 V DC 8 A for CANopen
    Description
    motor controller LTMR TeSys T - 24 V DC 8 A for CANopen
    Size pdf
    Size 195.3 KB
    Date 11/12/19
    Description
    motor controller LTMR TeSys T - 24 V DC 8 A for CANopen
    RoHs China Declaration
    Format
    Size
    Date
    Add to My Documents
    motor controller LTMR TeSys T - 24 V DC 8 A for CANopen
    Description
    motor controller LTMR TeSys T - 24 V DC 8 A for CANopen
    Size pdf
    Size 195.3 KB
    Date 11/12/19
    Description
    motor controller LTMR TeSys T - 24 V DC 8 A for CANopen
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.