Global (English)
Welcome to the Schneider Electric corporate Website

ENGLISH | FRENCH

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Tesys T
Schneider Electric LTMEV40BD Image

LTMEV40BD

Schneider Electric LTMEV40BD Image
LTMEV40BD

extension module LTME TeSys T - 24 V DC

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys T
    device short name
    LTME
    product or component type
    Extension module
    device application
    Equipment monitoring and control
    range compatibility
    TeSys T LTMR motor controller
    supply
    Via the controller
    Complementary
    [Ui] rated insulation voltage
    690 V conforming to CSA C22.2 No 14
    690 V conforming to EN/IEC 60947-1
    690 V conforming to UL 508
    [Uimp] rated impulse withstand voltage
    6 kV for current or voltage measurement circuit conforming to EN/IEC 60947-4-1
    0.8 kV for supply, inputs and outputs conforming to EN/IEC 60947-4-1
    logic input number
    4
    input current
    7 mA
    current state 0 guaranteed
    Logic input : < 5 V and <= 15 mA for 5 ms
    current state 1 guaranteed
    Logic input : < 15 V and 2...15 mA for 15 ms
    maximum output switching frequency
    2 Hz
    operating rate
    1800 cyc/h
    contacts type and composition
    Without
    metering type
    Active power P, P1, P2, P3
    Calculated active and reactive energy (+/- W.h, +/- VAR.h)
    Frequency
    Power factor
    Reactive power Q, Q1, Q2, Q3
    Voltage U21, U32, U13, V1, V2, V3
    Imbalance voltage
    measurement accuracy
    3 % power factor (cos φ > 0.6)
    1 % voltage (100...830 V)
    5 % active and reactive power
    overvoltage category
    III
    connection pitch
    5.08 mm
    connections - terminals
    Connector, 1 flexible cable with cable end 0.25...2.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 1 flexible cable without cable end 0.2...2.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 1 flexible cable without cable end 0.25...2.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 1 solid cable without cable end 0.2...2.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 2 flexible cable with cable end 0.2...1 mm² /AWG 24...AWG 14 for control circuit
    Connector, 2 flexible cable without cable end 0.2...1.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 2 flexible cable without cable end 0.5...1.5 mm² /AWG 24...AWG 14 for control circuit
    Connector, 2 solid cable without cable end 0.2...1 mm² /AWG 24...AWG 14 for control circuit
    tightening torque
    0.5...0.6 N.m, 3 mm flat screwdriver for control circuit
    pollution degree
    3
    electromagnetic compatibility
    ● electrostatic discharge 3 (8 kV air, 6 kV contact), conforming to EN/IEC 61000-4-2
    ● fast transients immunity test other circuits level 3 (2 kV), conforming to EN/IEC 61000-4-4
    ● fast transients immunity test on supply and relay outputs level 4 (4 kV), conforming to EN/IEC 61000-4-4
    ● conducted RF disturbances (10 V), conforming to EN/IEC 61000-4-6
    ● surges common mode (1 kV) control circuit, conforming to EN/IEC 61000-4-5
    ● surges serial mode (1 kV) control circuit, conforming to EN/IEC 61000-4-5
    ● surges common mode (2 kV) communication, conforming to EN/IEC 61000-4-5
    ● surges serial mode (2 kV) voltage inputs, conforming to EN/IEC 61000-4-5
    ● surges common mode (4 kV) voltage inputs, conforming to EN/IEC 61000-4-5
    width
    45 mm
    height
    61 mm
    depth
    120.7 mm
    product weight
    0.21 kg
    compatibility code
    LTME
    Environment
    standards
    EN 60947-4-1
    IACS E10
    IEC 60947-4-1
    UL 508
    CSA C22.2 No 14
    product certifications
    ABS
    ATEX
    BV
    CCC
    CSA
    C-Tick
    DNV
    GL
    KERI
    LROS (Lloyds register of shipping)
    NOM
    RINA
    RMRoS
    UL
    EAC
    IP degree of protection
    IP20
    protective treatment
    12 x 24 hour cycles conforming to EN/IEC 60068-2-30
    48 h conforming to EN/IEC 60070-2-11
    TH conforming to EN/IEC 60068
    fire resistance
    650 °C conforming to EN/IEC 60695-2-12
    960 °C conforming to UL 94
    ambient air temperature for operation
    -20...60 °C
    ambient air temperature for storage
    -40...80 °C
    operating altitude
    <= 2000 m without derating
    mechanical robustness
    ● shocks half sine wave acceleration (15 Gn for 11 ms) conforming to EN/IEC 60068-2-27
    ● vibrations mounted on symmetrical rail (1 Gn, 5...300 Hz) conforming to EN/IEC 60068-2-6
    ● vibrations plate mounted (4 Gn, 5...300 Hz) conforming to EN/IEC 60068-2-6
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • German
    • Chinese
    Catalogue
    Date
    Size
    Add to My Documents
    TeSys catalogue - 2019 - 2020 - chapter B12 Motor management systems TeSys LUTM, T (Version 6.0)
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)
    Catalogue TeSys 2019 - Chapitre B12 - Controleurs de moteurs (Version 4.0)
    User guide
    Date
    Size
    Add to My Documents
    TeSys T - Use in explosive atmospheres (Version 04)
    LTM R Modbus - Quick Start (Version 2.1)
    Date 12/1/10
    Size 1.3 MB
    LTM R DeviceNet - Quick Start (Version 2.1)
    Date 12/1/10
    Size 1.7 MB
    LTM R Profibus - Quick Start (Version 2.1)
    Date 12/1/10
    Size 1.5 MB
    LTM R Modbus / TCP - Quick Start (Version 1.1)
    LTM R CANopen - Quick Start (Version 2.1)
    Date 12/1/10
    Size 1.5 MB
    CAD
    Date
    Size
    Add to My Documents
    Extension module LTME TeSys T - 24 V DC (Version 1.0)
    Extention 4E control tension (Version 1.0)
    Date 3/27/14
    Size 476.1 KB
    Date 3/27/14
    Size 250.1 KB
    CAD file (on TraceParts) for LTMEV40BD: extension module LTME TeSys T - 24 V DC (Version 2.0)
    Extension module LTME TeSys T - 24 V DC (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    CB Certificate TeSys T, LTMR/LTMEV, made in China, according to IEC 60947-4-1 Ed3 (Version 1.0)
    CB Certificate TeSys T, LTMR/LTMEV, made in China, according to IEC 60947-4-1 Ed3 (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    LTM E - LTM R expansion module - Instruction sheet (Version 05)
    End of Life Information
    Date
    Size
    Add to My Documents
    End-of-Life Instructions TeSys T (Version 2.0)
    Date 3/31/16
    Size 218.7 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Système de gestion des moteurs (Version 1.0)
    Motor management system (Version 2.0)
    Date 3/31/16
    Size 287.1 KB
  • Technical FAQs