-
Characteristics
Main range TeSysproduct name TeSys LFproduct or component type Enclosed DOL starterdevice application AS interfacedevice composition Circuit-breakerAS interface moduleContactorutilisation category AC-3network type AC[Uc] control circuit voltage 24 V for AC circuit at 50/60 Hzthermal protection adjustment range 0.63...1 Acontrol type Rotary handle for protection control - OFF - Trip - ONComplementary motor power kW 0.18 kW at 400/415 V - AC at 50/60 Hznetwork frequency 50/60 Hz[Ue] rated operational voltage 415 V - AC at 50/60 Hz for power circuit250 V - AC at 50/60 Hz for output control relay30 V - DC for output control relay[Uimp] rated impulse withstand voltage 6 kV for power circuit conforming to IEC 60947-12.5 kV for 24 V conforming to IEC 60947-12.5 kV for sensor conforming to IEC 60947-12.5 kV for AS-Interface conforming to IEC 60947-1insulation resistance > 1000 mOhm between output and communicationinsulation 1500 V between output and ground1500 V between output and internal logicBetween input and communication[Ui] rated insulation voltage AC at 50/60 Hz conforming to IEC 60947[Ithe] conventional enclosed thermal current 5 A for output control relay at 40 °Cprotection type Inductive overvoltagePhase failurebreaking capacity 100 kA at 230/240 V conforming to IEC 60947-2100 kA at 400/415 V conforming to IEC 60947-2mechanical durability Circuit breaker : 0.1 McyclesContactor : 30 Mcycleselectrical durability Circuit breaker : 0.1 McyclesContactor : 0.8 Mcycles - AC-3 - 8.5 ARelay : 0.1 Mcycles - 24 V with 6 cyc/mn - AC-12 - 5 ARelay : 1 Mcycles - 24 V with 15 cyc/mn - AC-12 - 1 ARelay : 0.5 Mcycles - 24 V with 15 cyc/mn - AC-14 - 1 ARelay : 1 Mcycles - 24 V with 15 cyc/mn - AC-14 - 0.5 ARelay : 5 Mcycles - 24 V with 30 cyc/mn - AC-14 - 0.25 ARelay : 0.1 Mcycles - 24 V with 6 cyc/mn - DC-12 - 5 ARelay : 0.2 Mcycles - 24 V with 6 cyc/mn - DC-12 - 2 ARelay : 0.5 Mcycles - 24 V with 15 cyc/mn - DC-3 - 1 ARelay : >= 1 Mcycles - 24 V with 30 cyc/mn - DC-3 - 0.25 Acurrent consumption 20 mA for communication bus during operation60 mA for communication bus sensor0 mA at 24 V for supply circuit de-energisation30 mA at 24 V for supply circuit maintained mode110 mA at 24 V for supply circuit inrushlocal signalling Product status by 3 LEDsInput/output status by LEDnumber of inputs 2 M12nominal input value 19...30 V 50 mA - DCinput description Status D0 : forward stop - bit value 0Status D1 : reverse stop - bit value 0Status D2 : disable relay - bit value 0Status D3 : unused - bit value 0Status D0 : forward start - bit value 1Status D1 : reverse start - bit value 1Status D2 : enable relay - bit value 1Status D3 : unused - bit value 1input type Resistivesensor compatibility 2 or 3-wire PNPoutput description Command D0 : not ready - bit value 0Command D1 : stopped - bit value 0Command D2 : sensor 1 missing - bit value 0Command D3 : sensor 2 missing - bit value 0Command D0 : ready - bit value 1Command D1 : started - bit value 1Command D2 : sensor 1 present - bit value 1Command D3 : sensor 2 present - bit value 1response time Output control relay : <= 10 ms during closingOutput control relay : <= 15 ms during openingcontacts type and composition 1 C/OAS-interface profile 7A70 - extended A/Bcable gland type Supply circuit : Pg 16 - 10...15 mmPower circuit : Pg 16 - 10...15 mmOutput control relay : Pg 13 - 10...15 mmOutput control relay : Pg 16 - 10...15 mmconnections - terminals Supply circuit: screw clamp terminals 1 x 1.5...2 x 6 mm² rigidSupply circuit: screw clamp terminals 1 x 1.5...2 x 6 mm² flexible without cable endSupply circuit: screw clamp terminals 1 x 1.5...2 x 4 mm² flexible with cable endPower circuit: screw clamp terminals 1 x 1.5...2 x 4 mm² rigidPower circuit: screw clamp terminals 1 x 1.5...2 x 4 mm² flexible without cable endPower circuit: screw clamp terminals 1 x 1.5...1 x 2.5 mm² flexible with cable endOutput control relay: screw terminals 1 x 0.5...1 x 1.5 mm² rigidOutput control relay: screw terminals 1 x 0.5...1 x 1.5 mm² flexible without cable endOutput control relay: screw terminals 1 x 0.5...1 x 1.5 mm² flexible with cable endtightening torque Supply circuit : 1.7 N.m - with screwdriver flat Ø 5.5 mmPower circuit : 0.8 N.m - with screwdriver flat Ø 5.5 mmOutput control relay : 0.7 N.m - with screwdriver flat Ø 3.5 mmwidth 219 mmheight 245 mmdepth 179 mmproduct weight 1.3 kgEnvironment electromagnetic compatibility Electrostatic discharge 8 kV level 3 - in air - conforming to EN/IEC 61000-4-2Electrostatic discharge 4 kV level 2 - in indirect mode - conforming to EN/IEC 61000-4-2Electrical fast transient/burst immunity test 2 kV level 3 conforming to EN/IEC 61000-4-4Surge immunity test 4 kV level 4 - power, line to ground - conforming to IEC 61000-4-5Surge immunity test 2 kV level 4 - power, line to line - conforming to EN/IEC 61000-4-5Surge immunity test 2 kV level 2 - control circuit, line to ground - conforming to IEC 61000-4-5Surge immunity test 500 V level 2 - control circuit, line to line - conforming to EN/IEC 61000-4-5Conducted RF disturbances 10 V/m conforming to IEC 61000-4-6Conducted RF disturbances 10 V/m conforming to ENV 50141Radiated radio-frequency electromagnetic field immunity test 10 V/m conforming to IEC 61000-4-3Radiated radio-frequency electromagnetic field immunity test 10 V/m conforming to ENV 50204Radiated radio-frequency electromagnetic field immunity test 10 V/m conforming to ENV 50140Disturbing field emission class B conforming to ENV 55011Disturbing field emission class B conforming to CISPR 11mechanical robustness Shocks : 10 Gn during contactor open conforming to IEC 60068-2-27Shocks : 15 gn during contactor closed conforming to IEC 60068-2-27Vibrations : 2 Gn during contactor open conforming to IEC 60068-2-6Vibrations : 4 Gn during contactor closed conforming to IEC 60068-2-6IP degree of protection IP54 conforming to IEC 60529protective treatment TCfire resistance 960 °C conforming to IEC 60695-2-1operating altitude 2000 mstandards EN 60204-1EN 60439-1EN 60947-1IEC 60204-1IEC 60439-1IEC 60947-1UL 508CSA C22.2 No 14material Steel - white : RAL 9001ambient air temperature for operation -5...40 °C conforming to IEC 61439-1ambient air temperature for storage -40...80 °C conforming to IEC 61439-1Offer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
Instruction sheetSizeAdd to My DocumentsLF3-LF4 Enclosed starter for AS-Interface - Instruction sheet (Version 02)End of Life InformationSizeAdd to My DocumentsEU RoHS DeclarationSizeAdd to My DocumentsProduct Environmental ProfileSizeAdd to My DocumentsREACh DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.