  • Main
    range
    TeSys
    product name
    TeSys F
    product or component type
    Star delta starter
    device short name
    LC3F
    contactor application
    Motor control
    utilisation category
    AC-3
    device presentation
    Pre-wired
    poles description
    3 x 3P
    power pole contact composition
    3 x 3 NO
    [Ue] rated operational voltage
    <= 1000 V AC 16 Hz 2/3...200 Hz for power circuit
    [Ie] rated operational current
    115 A (<= 55 °C) AC AC-3 for power circuit at <= 440 V
    motor power kW
    52 kW at 220/230 V AC 50/60 Hz
    85 kW at 380/400 V AC 50/60 Hz
    102 kW at 415 V AC 50/60 Hz
    102 kW at 440 V AC 50/60 Hz
    control circuit type
    AC 50/60 Hz
    [Uc] control circuit voltage
    110 V AC 50/60 Hz
    [Uimp] rated impulse withstand voltage
    8 kV
    [Ui] rated insulation voltage
    1000 V conforming to IEC 60947-4-1
    1500 V conforming to VDE 0110 group C
    interlocking type
    Without start delta mechanical interlock
    mounting support
    Plate
    standards
    IEC 60947-4-1
    IEC 60947-1
    EN 60947-4-1
    JIS C8201-4-1
    EN 60947-1
    product certifications
    CCC
    ABS
    RMRoS
    UL
    RINA
    LROS (Lloyds register of shipping)
    CSA
    CB
    DNV
    Complementary
    [Ith] conventional free air thermal current
    200 A at <= 40 °C
    Irms rated making capacity
    1150 A conforming to IEC 60947-4-1
    rated breaking capacity
    920 A conforming to IEC 60947-4-1
    [Icw] rated short-time withstand current
    1100 A at <= 40 °C for 10 s
    640 A at <= 40 °C for 30 s
    520 A at <= 40 °C for 1 min
    400 A at <= 40 °C for 3 min
    320 A at <= 40 °C for 10 min
    associated fuse rating
    125 A aM at <= 440 V
    200 A gG at <= 440 V
    connections - terminals
    Screw clamp terminals for control circuit 1 1...4 mm² flexible without cable end
    Screw clamp terminals for control circuit 2 1...4 mm² flexible without cable end
    Screw clamp terminals for control circuit 1 1...4 mm² flexible with cable end
    Screw clamp terminals for control circuit 2 1...2.5 mm² flexible with cable end
    Screw clamp terminals for control circuit 1 1...4 mm² solid without cable end
    Screw clamp terminals for control circuit 2 1...4 mm² solid without cable end
    Bar for power circuit 2 20 x 3 mm
    Bolted connection for power circuit
    Lugs-ring terminals for power circuit 1 95 mm²
    Connector for power circuit 1 95 mm²
    connections bolt diameter
    M6
    tightening torque
    10 N.m for power circuit
    1.2 N.m for control circuit
    operating time
    23...35 ms closing
    5...15 ms opening
    mechanical durability
    10 Mcycles
    operating rate
    2400 cyc/h at <= 55 °C
    starting time
    20 s
    control circuit voltage limits
    0.35...0.55 Uc at 55 °C drop-out 50/60 Hz
    0.85...1.1 Uc at 55 °C operational 50/60 Hz
    inrush power in VA
    550 VA at 20 °C 0.3 50 Hz
    660 VA at 20 °C 0.3 60 Hz
    hold-in power consumption in VA
    45 VA at 20 °C 0.3 50 Hz
    55 VA at 20 °C 0.3 60 Hz
    heat dissipation
    12...16 W
    Environment
    IP degree of protection
    IP20 front face with shrouds conforming to IEC 60529
    IP20 front face with shrouds conforming to VDE 0106
    protective treatment
    TH
    ambient air temperature for storage
    -60...80 °C
    ambient air temperature for operation
    -5...55 °C
    -40...70 °C at Uc
    operating altitude
    3000 m without derating
    mechanical robustness
    Vibrations contactor closed 6 Gn, 5...300 Hz
    Shocks contactor open 9 Gn for 11 ms
    Vibrations contactor open 2 Gn, 5...300 Hz
    Shocks contactor closed 15 Gn for 11 ms
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  1827  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Product end of life instructions
  • Documents and Downloads

    Language
    • English
    Brochure
    Date
    Size
    Add to My Documents
    TeSys F 1000 leaflet (Version 1.0)
    Date 11/26/15
    Size 6.1 MB
    Date 11/26/15
    Size 819.5 MB
    Instruction sheet
    Date
    Size
    Add to My Documents
    LE3 F/LC3 F Star/delta starters (Version 03)
    End of Life Information
    Date
    Size
    Add to My Documents
    End-of-Life Instructions TeSys LC1F185 to LC1F225 (Version 1.0)
    TeSys LC1F185-225 - EoLi (Version 2.0)
    Date 12/1/15
    Size 181.1 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    TeSys contactor LC1F (Version 2.0)
    Date 9/8/15
    Size 197.1 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /