  • Main
    range
    TeSys
    product name
    TeSys D
    product or component type
    Star delta starter
    device short name
    LC3D
    contactor application
    Motor control
    utilisation category
    AC-3
    device presentation
    Pre-wired
    poles description
    3 x 3P
    power pole contact composition
    3 x 3 NO
    [Ue] rated operational voltage
    <= 690 V AC 25...400 Hz for power circuit
    [Ie] rated operational current
    115 A (<= 60 °C) AC AC-3 for power circuit at <= 440 V
    motor power kW
    110 kW at 380/400 V AC 50/60 Hz
    110 kW at 415 V AC 50/60 Hz
    110 kW at 440 V AC 50/60 Hz
    63 kW at 220/230 V AC 50/60 Hz
    control circuit type
    AC 50/60 Hz
    [Uc] control circuit voltage
    400 V AC 50/60 Hz
    auxiliary contact composition
    1 NC for KM2 line contactor
    1 NO for KM3 delta contactor
    [Uimp] rated impulse withstand voltage
    8 kV conforming to IEC 60947
    overvoltage category
    III
    [Ui] rated insulation voltage
    600 V certifications CSA power circuit
    600 V certifications UL power circuit
    600 V certifications CSA signalling circuit
    600 V certifications UL signalling circuit
    1000 V conforming to IEC 60947-4-1 power circuit
    1000 V conforming to IEC 60947-1 signalling circuit
    electrical durability
    0.95 Mcycles 115 A AC-3 <= 440 V
    mounting support
    Plate
    standards
    IEC 60947-4-1
    UL 508
    EN 60947-4-1
    EN 60947-5-1
    CSA C22.2 No 14
    IEC 60947-5-1
    product certifications
    UL
    GL
    CCC
    BV
    RINA
    GOST
    CSA
    DNV
    LROS (Lloyds register of shipping)
    Complementary
    connections - terminals
    Connector for power circuit 1 10...120 mm² flexible without cable end
    Connector for power circuit 2 10...50 mm² flexible without cable end
    Connector for power circuit 1 10...120 mm² flexible with cable end
    Connector for power circuit 2 10...50 mm² flexible with cable end
    Connector for power circuit 1 10...120 mm² solid without cable end
    Connector for power circuit 2 10...50 mm² solid without cable end
    Connector for control circuit 1 1...2.5 mm² flexible without cable end
    Connector for control circuit 2 1...2.5 mm² flexible without cable end
    Connector for control circuit 1 1...2.5 mm² flexible with cable end
    Connector for control circuit 2 1...2.5 mm² flexible with cable end
    Connector for control circuit 1 1...2.5 mm² solid without cable end
    Connector for control circuit 2 1...2.5 mm² solid without cable end
    tightening torque
    12 N.m for power circuit connector flat Ø 6...8 mm
    1.2 N.m for control circuit connector flat Ø 6 mm
    1.2 N.m for control circuit connector Philips No 2
    mechanical durability
    8 Mcycles
    operating rate
    30 cyc/h at <= 60 °C
    starting time
    30 s
    coil technology
    Without built-in suppressor module
    control circuit voltage limits
    0.3...0.5 Uc at 55 °C drop-out 50/60 Hz
    0.8...1.15 Uc at 55 °C operational 50/60 Hz
    inrush power in VA
    280...350 VA at 20 °C 0.8 60 Hz
    280...350 VA at 20 °C 0.8 50 Hz
    hold-in power consumption in VA
    2...18 VA at 20 °C 0.3 60 Hz
    2...18 VA at 20 °C 0.3 50 Hz
    heat dissipation
    3...8 W at 50/60 Hz
    auxiliary contacts type
    Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC
    Mirror contact conforming to IEC 60947-4-1 3 x 1 NC
    signalling circuit frequency
    25...400 Hz
    minimum switching current
    For signalling circuit
    minimum switching voltage
    17 V for signalling circuit
    non-overlap time
    1.5 ms on energisation between NC and NO contact
    1.5 ms on de-energisation between NC and NO contact
    width
    450 mm
    height
    555 mm
    depth
    205 mm
    product weight
    11.8 kg
    Environment
    insulation resistance
    > 10 MOhm for signalling circuit
    IP degree of protection
    IP20 front face conforming to IEC 60529
    protective treatment
    TH conforming to IEC 60068-2-30
    pollution degree
    3
    ambient air temperature for storage
    -60...80 °C
    ambient air temperature for operation
    -40...70 °C at Uc
    operating altitude
    3000 m without derating
    fire resistance
    850 °C conforming to IEC 60695-2-1
    flame retardance
    V1 conforming to UL 94
    mechanical robustness
    Vibrations contactor open 2 Gn, 5...300 Hz
    Vibrations contactor closed 4 Gn, 5...300 Hz
    Shocks contactor closed 15 Gn for 11 ms
    Shocks contactor open 6 Gn for 11 ms
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    Catalogue
    Date
    Size
    Add to My Documents
    TeSys catalogue - 2019 - 2020 - chapter A2 - open, pre-cabled motor starters (Version 6.0)
    Catalogue TeSys - 2019 - Chapitre A2 - Démarreurs-moteurs nus pré-cablés (Version 4.0)
    Catalogue TeSys 2019 - Composants pour protection et commande de moteurs (Version 7.1)
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    End of Life Information
    Date
    Size
    Add to My Documents
    End-of-Life Instructions TeSys LC1D115 (Version 1.0)
    TeSys D LC1 D115-D150 - EoLi (Version 2.0)
    Date 12/1/15
    Size 151.6 KB
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    PEP - TeSys D LC1D115 to D150 contactors (Version 2.0)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /