    • Characteristics

      Main
      range of product
      TeSys D
      range
      TeSys
      product name
      TeSys D
      product or component type
      Contactor
      device short name
      LC1D
      contactor application
      Resistive load
      utilisation category
      AC-1
      poles description
      4P
      pole contact composition
      4 NO
      [Ue] rated operational voltage
      <= 690 V AC for power circuit
      <= 300 V DC 25...400 Hz for power circuit
      [Ie] rated operational current
      125 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
      control circuit type
      AC 50/60 Hz
      [Uc] control circuit voltage
      220 V AC 50/60 Hz
      [Uimp] rated impulse withstand voltage
      Conforming to IEC 60947
      overvoltage category
      III
      [Ith] conventional free air thermal current
      125 A at <= 60 °C for power circuit
      Irms rated making capacity
      1100 A at 440 V for power circuit conforming to IEC 60947
      rated breaking capacity
      1100 A at 440 V for power circuit conforming to IEC 60947
      [Icw] rated short-time withstand current
      135 A <= 40 °C 10 min power circuit
      640 A <= 40 °C 10 s power circuit
      990 A <= 40 °C 1 s power circuit
      320 A <= 40 °C 1 min power circuit
      associated fuse rating
      160 A gG at <= 690 V coordination type 2 for power circuit
      200 A gG at <= 690 V coordination type 1 for power circuit
      average impedance
      0.8 mOhm at 50 Hz - Ith 125 A for power circuit
      [Ui] rated insulation voltage
      1000 V for power circuit conforming to IEC 60947-4-1
      600 V for power circuit certifications CSA
      600 V for power circuit certifications UL
      electrical durability
      0.8 Mcycles 125 A AC-1 at Ue <= 440 V
      power dissipation per pole
      12.5 W AC-1
      protective cover
      Without
      mounting support
      Plate
      Rail
      standards
      CSA C22.2 No 14
      EN 60947-4-1
      EN 60947-5-1
      IEC 60947-4-1
      IEC 60947-5-1
      UL 508
      product certifications
      DNV
      GL
      RINA
      CCC
      LROS (Lloyds register of shipping)
      CSA
      GOST
      BV
      UL
      connections - terminals
      Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
      Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
      Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
      Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
      Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
      Control circuit : screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
      Power circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: flexible - without cable end
      Power circuit : connector 2 cable(s) 4...25 mm² - cable stiffness: flexible - without cable end
      Power circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: flexible - with cable end
      Power circuit : connector 2 cable(s) 4...16 mm² - cable stiffness: flexible - with cable end
      Power circuit : connector 1 cable(s) 4...50 mm² - cable stiffness: solid - without cable end
      Power circuit : connector 2 cable(s) 4...25 mm² - cable stiffness: solid - without cable end
      tightening torque
      Power circuit : 9 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
      Power circuit : 9 N.m - on connector hexagonal 4 mm
      Control circuit : 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
      Control circuit : 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
      operating time
      20...35 ms closing
      6...20 ms opening
      safety reliability level
      B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
      B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
      mechanical durability
      4 Mcycles
      operating rate
      3600 cyc/h at <= 60 °C
      Complementary
      coil technology
      Without built-in suppressor module
      control circuit voltage limits
      0.85...1.1 Uc operational at 55 °C, AC 60 Hz
      0.3...0.6 Uc drop-out at 55 °C, AC 50/60 Hz
      0.8...1.1 Uc operational at 55 °C, AC 50 Hz
      inrush power in VA
      245 VA at 20 °C (cos ϕ 0.75) 60 Hz
      245 VA at 20 °C (cos ϕ 0.75) 50 Hz
      hold-in power consumption in VA
      26 VA at 20 °C (cos ϕ 0.3) 60 Hz
      26 VA at 20 °C (cos ϕ 0.3) 50 Hz
      heat dissipation
      6...10 W at 50/60 Hz
      Environment
      IP degree of protection
      IP20 front face conforming to IEC 60529
      protective treatment
      TH conforming to IEC 60068-2-30
      pollution degree
      3
      ambient air temperature for operation
      -5...60 °C
      ambient air temperature for storage
      -60...80 °C
      permissible ambient air temperature around the device
      -40...70 °C at Uc
      operating altitude
      3000 m without derating in temperature
      fire resistance
      850 °C conforming to IEC 60695-2-1
      flame retardance
      V1 conforming to UL 94
      mechanical robustness
      Vibrations contactor open 2 Gn, 5...300 Hz
      Shocks contactor open 8 Gn for 11 ms
      Vibrations contactor closed 3 Gn, 5...300 Hz
      Shocks contactor closed 10 Gn for 11 ms
      height
      127 mm
      width
      96 mm
      depth
      125 mm
      product weight
      1.76 kg
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)
      Compliant  - since  0701  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity
      REACh
      Product environmental profile
      Product end of life instructions
      Need no specific recycling operations
      Contractual warranty
      Warranty period
      18 months
    • Documents and Downloads (2)

    Support

    Ask. We answer

    Loading

    See all FAQs