
TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
Show more characteristics >-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Resistive loadutilisation category AC-1poles description 4Ppower pole contact composition 2 NO + 2 NC[Ue] rated operational voltage <= 300 V DC for power circuit<= 690 V AC 25...400 Hz for power circuit[Ie] rated operational current 80 A (<= 60 °C) at <= 440 V AC AC-1 for power circuitcontrol circuit type AC 50 Hz[Uc] control circuit voltage 12 V AC 50 Hz[Uimp] rated impulse withstand voltage Conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 80 A at <= 60 °C for power circuitIrms rated making capacity 1000 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 520 A <= 40 °C 10 s power circuit900 A <= 40 °C 1 s power circuit110 A <= 40 °C 10 min power circuit260 A <= 40 °C 1 min power circuitassociated fuse rating 125 A gG at <= 690 V coordination type 1 for power circuit125 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 1.5 mOhm at 50 Hz - Ith 80 A for power circuit[Ui] rated insulation voltage 600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for power circuit conforming to IEC 60947-4-1electrical durability 1.4 Mcycles 80 A AC-1 at Ue <= 440 Vpower dissipation per pole 9.6 W AC-1safety cover Withoutmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications BVCCCCSADNVGLGOSTLROS (Lloyds register of shipping)RINAULconnections - terminals Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable endControl circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable endPower circuit : screw clamp terminals 1 cable(s) 1...35 mm² - cable stiffness: flexible - without cable endPower circuit : screw clamp terminals 2 cable(s) 1...25 mm² - cable stiffness: flexible - without cable endPower circuit : screw clamp terminals 1 cable(s) 1...35 mm² - cable stiffness: flexible - with cable endPower circuit : screw clamp terminals 2 cable(s) 1...25 mm² - cable stiffness: flexible - with cable endPower circuit : screw clamp terminals 1 cable(s) 1...35 mm² - cable stiffness: solid - without cable endPower circuit : screw clamp terminals 2 cable(s) 1...25 mm² - cable stiffness: solid - without cable endtightening torque Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit : 8 N.m - on screw clamp terminals - cable 25...35 mm² hexagonal 4 mmPower circuit : 5 N.m - on screw clamp terminals - cable 1...25 mm² hexagonal 4 mmoperating time 12...26 ms closing4...19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 6 Mcyclesoperating rate 3600 cyc/h at <= 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits 0.8...1.1 Uc operational at 60 °C, AC 50 Hz0.3...0.6 Uc drop-out at 60 °C, AC 50 Hzinrush power in VA 160 VA at 20 °C (cos ϕ 0.75) 50 Hzhold-in power consumption in VA 15 VA at 20 °C (cos ϕ 0.3) 50 Hzheat dissipation 4...5 W at 50 HzEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5...60 °Cambient air temperature for storage -60...80 °Cpermissible ambient air temperature around the device -40...70 °C at Ucoperating altitude 3000 m without derating in temperaturefire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor open 10 Gn for 11 msShocks contactor closed 15 Gn for 11 msheight 127 mmwidth 85 mmdepth 125 mmproduct weight 1.45 kgOffer Sustainability RoHS (date code: YYWW) Product end of life instructions Need no specific recycling operationsContractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- Portuguese
- French
- Czech
- German
- Swedish
- Dutch
CADSizeAdd to My DocumentsCONTACTOR (Version 1.0)EU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.