TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 440 V AC 50/60 Hz coil
Show more characteristics >-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Motor controlResistive loadutilisation category AC-3AC-1AC-4poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage <= 300 V DC for power circuit<= 690 V AC 25...400 Hz for power circuit[Ie] rated operational current 50 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit80 A (<= 60 °C) at <= 440 V AC AC-1 for power circuitmotor power kW 22 kW at 380...400 V AC 50/60 Hz AC-325 kW at 415 V AC 50/60 Hz AC-330 kW at 440 V AC 50/60 Hz AC-330 kW at 500 V AC 50/60 Hz AC-333 kW at 660...690 V AC 50/60 Hz AC-315 kW at 220...230 V AC 50/60 Hz AC-311 kW at 400 V AC 50/60 Hz AC-4motor power HP (UL / CSA) 3 hp at 115 V AC 50/60 Hz for 1 phase motors7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors15 hp at 200/208 V AC 50/60 Hz for 3 phases motors15 hp at 230/240 V AC 50/60 Hz for 3 phases motors40 hp at 460/480 V AC 50/60 Hz for 3 phases motors40 hp at 575/600 V AC 50/60 Hz for 3 phases motorscontrol circuit type AC 50/60 Hz[Uc] control circuit voltage 440 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage Conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 80 A at <= 60 °C for power circuit10 A at <= 60 °C for signalling circuitIrms rated making capacity 900 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuit400 A <= 40 °C 10 s power circuit810 A <= 40 °C 1 s power circuit84 A <= 40 °C 10 min power circuit208 A <= 40 °C 1 min power circuitassociated fuse rating 100 A gG at <= 690 V coordination type 1 for power circuit100 A gG at <= 690 V coordination type 2 for power circuit10 A gG for signalling circuit conforming to IEC 60947-5-1average impedance 1.5 mOhm at 50 Hz - Ith 80 A for power circuit[Ui] rated insulation voltage 600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for power circuit conforming to IEC 60947-4-1690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications ULelectrical durability 1.45 Mcycles 50 A AC-3 at Ue <= 440 V1.1 Mcycles 80 A AC-1 at Ue <= 440 Vpower dissipation per pole 3.7 W AC-39.6 W AC-1safety cover Withmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications DNVBVLROS (Lloyds register of shipping)RINACCCULCSAGOSTGLconnections - terminals Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable endControl circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable endControl circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable endPower circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: flexible - with cable endPower circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: solid - without cable endPower circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: flexible - without cable endPower circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: solid - without cable endPower circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: flexible - without cable endPower circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: flexible - with cable endtightening torque Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit : 8 N.m - on EverLink BTR screw connectors - cable 25...35 mm² hexagonal 4 mmPower circuit : 5 N.m - on EverLink BTR screw connectors - cable 1...25 mm² hexagonal 4 mmoperating time 12...26 ms closing4...19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 6 Mcyclesoperating rate 3600 cyc/h at <= 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits 0.3...0.6 Uc drop-out at 60 °C, AC 50/60 Hz0.8...1.1 Uc operational at 60 °C, AC 50 Hz0.85...1.1 Uc operational at 60 °C, AC 60 Hzinrush power in VA 140 VA at 20 °C (cos ϕ 0.75) 60 Hz160 VA at 20 °C (cos ϕ 0.75) 50 Hzhold-in power consumption in VA 13 VA at 20 °C (cos ϕ 0.3) 60 Hz15 VA at 20 °C (cos ϕ 0.3) 50 Hzheat dissipation 4...5 W at 50/60 Hzauxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact)insulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5...60 °Cambient air temperature for storage -60...80 °Cpermissible ambient air temperature around the device -40...70 °C at Ucoperating altitude 3000 m without derating in temperaturefire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor open 10 Gn for 11 msShocks contactor closed 15 Gn for 11 msheight 122 mmwidth 55 mmdepth 120 mmproduct weight 0.855 kgOffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- Danish
- French
- Finnish
- Chinese
- Norwegian
- Dutch
- Turkish
- Portuguese
- Russian
- Czech
- Polish
- Italian
- German
- Swedish
CADSizeAdd to My Documents3P EVLK CONT 40A 18,5KW (Version 1.0)CAD files for LC1D50AR7: TeSys D contactors for control in category AC-1 - For connection by screw clamp terminals and lugs - A.C. supply (Version 1.0)Date 2/6/19Size 177.5 KBCertificateSizeAdd to My DocumentsCCC Cert TeSys D - LC.D40A-80A_LC.DT60A-80A, France (Version 1.0)Instruction sheetSizeAdd to My DocumentsLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 (Version 14)Date 12/19/18Size 7.4 MBEnd of Life InformationSizeAdd to My DocumentsTeSys D 40, 50, 65A - EoLi (Version 1.0)Product Environmental ProfileSizeAdd to My DocumentsREACh DeclarationSizeAdd to My DocumentsEU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.