
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 250 V DC standard coil
Show more characteristics >-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Motor controlResistive loadutilisation category AC-3AC-1AC-4poles description 3Ppower pole contact composition 3 NO[Ue] rated operational voltage <= 300 V DC for power circuit<= 690 V AC 25...400 Hz for power circuit[Ie] rated operational current 50 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit80 A (<= 60 °C) at <= 440 V AC AC-1 for power circuitmotor power kW 22 kW at 380...400 V AC 50/60 Hz AC-325 kW at 415 V AC 50/60 Hz AC-330 kW at 440 V AC 50/60 Hz AC-330 kW at 500 V AC 50/60 Hz AC-333 kW at 660...690 V AC 50/60 Hz AC-315 kW at 220...230 V AC 50/60 Hz AC-311 kW at 400 V AC 50/60 Hz AC-4motor power HP (UL / CSA) 3 hp at 115 V AC 50/60 Hz for 1 phase motors7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors15 hp at 200/208 V AC 50/60 Hz for 3 phases motors15 hp at 230/240 V AC 50/60 Hz for 3 phases motors40 hp at 460/480 V AC 50/60 Hz for 3 phases motors40 hp at 575/600 V AC 50/60 Hz for 3 phases motorscontrol circuit type DC standard[Uc] control circuit voltage 250 V DCauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage Conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 80 A at <= 60 °C for power circuit10 A at <= 60 °C for signalling circuitIrms rated making capacity 900 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuit400 A <= 40 °C 10 s power circuit810 A <= 40 °C 1 s power circuit84 A <= 40 °C 10 min power circuit208 A <= 40 °C 1 min power circuitassociated fuse rating 100 A gG at <= 690 V coordination type 1 for power circuit100 A gG at <= 690 V coordination type 2 for power circuit10 A gG for signalling circuit conforming to IEC 60947-5-1average impedance 1.5 mOhm at 50 Hz - Ith 80 A for power circuit[Ui] rated insulation voltage 600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for power circuit conforming to IEC 60947-4-1690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications ULelectrical durability 1.45 Mcycles 50 A AC-3 at Ue <= 440 V1.1 Mcycles 80 A AC-1 at Ue <= 440 Vpower dissipation per pole 3.7 W AC-39.6 W AC-1safety cover Withmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications RINALROS (Lloyds register of shipping)BVCCCDNVCSAGOSTULGLconnections - terminals Power circuit : EverLink BTR screw connectors 1 cable(s) 1...35 mm² - cable stiffness: flexible - without cable endPower circuit : EverLink BTR screw connectors 1 cable(s) 1...35 mm² - cable stiffness: flexible - with cable endPower circuit : EverLink BTR screw connectors 1 cable(s) 1...35 mm² - cable stiffness: solid - without cable endPower circuit : EverLink BTR screw connectors 2 cable(s) 1...25 mm² - cable stiffness: flexible - without cable endPower circuit : EverLink BTR screw connectors 2 cable(s) 1...25 mm² - cable stiffness: flexible - with cable endPower circuit : EverLink BTR screw connectors 2 cable(s) 1...25 mm² - cable stiffness: solid - without cable endControl circuit : spring terminals 1 cable(s) 2.5 mm² - cable stiffness: flexible - without cable endControl circuit : spring terminals 2 cable(s) 2.5 mm² - cable stiffness: flexible - without cable endtightening torque Power circuit : 8 N.m - on EverLink BTR screw connectors - cable 25...35 mm² hexagonal 4 mmPower circuit : 5 N.m - on EverLink BTR screw connectors - cable 1...25 mm² hexagonal 4 mmoperating time 16...24 ms opening42.5...57.5 ms closingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 10 Mcyclesoperating rate 3600 cyc/h at <= 60 °CComplementary coil technology Built-in bidirectional peak limiting diode suppressorcontrol circuit voltage limits 0.1...0.3 Uc drop-out at 60 °C, DC0.75...1.25 Uc operational at 60 °C, DCtime constant 34 msinrush power in W 19 W at 20 °Chold-in power consumption in W 7.4 W at 20 °Cauxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact)insulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5...60 °Cambient air temperature for storage -60...80 °Cpermissible ambient air temperature around the device -40...70 °C at Ucoperating altitude 3000 m without derating in temperaturefire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor open 10 Gn for 11 msShocks contactor closed 15 Gn for 11 msheight 122 mmwidth 55 mmdepth 120 mmproduct weight 0.93 kgOffer Sustainability RoHS (date code: YYWW) Product end of life instructions Contractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- Portuguese
- Russian
- French
- Italian
- Chinese
- German
CADSizeAdd to My Documents3P EVLK CONT 40A 18,5KW (Version 1.0)CertificateSizeAdd to My DocumentsCCC Cert TeSys D - LC.D40A-80A_LC.DT60A-80A, France (Version 1.0)Instruction sheetSizeAdd to My DocumentsLC1D..A, LC1D..A3, LC2D..A, LC2D..A3 Everlink 3-pole contactors and reversing contactors 40 to 80 A AC-3 (Version 14)Date 12/19/18Size 7.4 MBEnd of Life InformationSizeAdd to My DocumentsTeSys D 40, 50, 65A - EoLi (Version 1.0)Product Environmental ProfileSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.